![Right Weigh 201-219-11 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/right-weigh/201-219-11/201-219-11_installation-and-operation-manual_1460676010.webp)
SENSOR CHECKING / ADJUSTMENT
10
Only perform the following checks when the vehicle is
empty
FIND SENSOR OUTPUT SCREEN
2
If your sensor value(s) are within 6.500 and
7.500, move on to step 4
!
At this time, you should have the scale and all strain sensors installed onto
your truck. Once this is complete, it is time to adjust the strain sensor(s).
TURN ON DIAGNOSTICS MODE
1
With the scale turned off, hold
down the MENU button and then
press the ON/OFF button -
release both at the same time.
This will display the software
version on the scale.
Press the MENU button three
times; a four digit number will
appear representing the raw
output from sensor 1.
For multiple sensors, hit the UP
ARROW to see the values for
sensors 2 and 3.
PRESS
HOLDING
Содержание 201-219-11