RI-1313-(2) Revision 1.0
5/3/2001
page 30
Step 1
Reserve locking loop supplied with CYPRES MUST be
used. Special discs supplied with CYPRES must also be used to
make knots for locking loop.
Step 2
Adjust locking loop to appropriate length in accordance
with Table IV. Install locking loop into container.
Step 3
Install CYPRES processing unit into pocket provided on
divider wall at bottom of reserve container.
(Figure 40).
Step 4
Thread cutter unit up through grommet and then through
channel provided on inside of right reserve side flap. Push cutter
through elastic keeper next to grommet and align hole in cutter with
grommet.
(Figure 41).
Step 6
Carefully stow excess cutter cable under Velcro closure
flap located on right end of Cypres installation pocket. Do this by
coiling excess. DO NOT bend or kink excess cable.
(Figure
42)
Step 7
Carefully push control unit through channel on bottom of
reserve container from bottom to top
. Note: channel begins at
lower extreme of reserve riser cover flap and is between riser
cover flap and pack tray stiffener
(Figure
43)
.
Step 8
Gently slide control unit through opening on under side of
reserve top flap (
Figure
44)and into slit opening for clear pocket.
Double check that control button, display and red light are visible in
pocket window.
(Figure
45)
Step 9
Pull slack in control cable back down into pack tray. Coil
excess cable neatly without kinks or sharp folds into pocket on
pack tray at bottom of stiffener.
Figure 40
Figure 41
Figure 42
Figure 43
Figure 44
Figure 45