Operating Manual

Breite: 170 

Höhe:8,15

Oben Links

278,5   20 

RIFOX - Hans Richter GmbH Spezialarmaturen Fon: +49 (0) 421 499 75 - 0          Internet:    www.rifox.de 
Bertha-von-Suttner-Str. 9     D-28207 Bremen Fax: +49 (0) 421 499 75 - 40         Email: [email protected]

Page 2 of 5

08/2020

-Di.

 Subject to modifi

 ca

tions

1000

10000

0,1

1

10

Flow

 rate in 

kg/h 

Pressure difference in bar (with reference to atmospheric pressure)

50000

25

1000

10000

0,1

1

10

Flow

 rate in 

kg/h 

Pressure difference in bar (with reference to atmospheric pressure)

40000

25

2.2 

Operation limits of housing material (Design)

For Model WO-1111 and EF-1112:

max. operating pressure (bar g)

25

23,2

20,8

17,2

14,8

max. operating temperature (°C)

-10/20

100

200

300

400*

* only with screw material A4-70/ 1,4571/ 1.4104

For Model WO-1111-N and EF-1112-N:

max. operating pressure (bar g)

25

23,3

20,8

19,5

max. operating temperature (°C)

100

200

300

400

2.3 

Function limit of control unit 

(for all four models)

Cross-section

Max. line pressure in bar g / Steam

Max. line pressure in bar g / Compressed air

20/190

12 / 22*

12 / 25*

20/340

8 / 14*

8 / 17

20/412

8 / 14*

8 / 17

Special design with oval fl oat

2.4 

Discharge capacity 

(for all four models, for hot condensate)

 

2.5 Function

 Due to the gravity the condensate fl ows downwards to the lowest point, which is the condensate trap housing. In the 

lowest position of the fl oat the outlet cross-section is close. Rising of the liquid level lifts the fl oat and opens the outlet. 
Condensate will be discharged through the upturned immersion tube. Decreasing condensate level closes the outlet again.

2.6 

Compensation line

 In order to get proper function, the non-condensable gas must be able to leave the housing. Due to the vertical installation, 

the non-condensable gas is able to leave the housing and fl ows into the steam/gas chamber above it, which has the same 
pressure level. If the self-venting through the pipe must be extended, the control screw (4) can be replaced by a cutting ring 
screw bolt and a compensation line can be installed leading upwards. 

2.7 

Automatic venting

 In the case of steam applications, automatic venting must be provided (vent jet).

2.8 

Gastight under-level fl oat control (only for gas applications)

 For gas applications, a gastight under-level fl oat control is nearly exclusively used. Consult with Rifox, if necessary.

Picture 3 

Picture 4 

For Model WO-1111 and EF-1112

For Model WO-1111-N and EF-1112-N:

For the cold condensate the discharge capacity is 
higher because of medium temperature and density.

For the hot condensate the discharge capacity is 
lower because of medium temperature and density.