Operating Manual
0
6
/202
2
-Di.
Subject to modifica
tions
Page 1 of 5
Breite: 170
Höhe:8,15
Oben Links
278,5 20
RIFOX - Hans Richter GmbH Spezialarmaturen Fon: +49 (0) 421 499 75 - 0 Internet: www.rifox.de
Bertha-von-Suttner-Str. 9 D-28207 Bremen Fax: +49 (0) 421 499 75 - 40 Email: [email protected]
Model: 1277-N / 1278-N
RIFOmat Float-Controlled Trap, Model Minox, PN 40
1
Safety instructions
1.1
Proper use
Any improper use, intervention in the design and deviation from the design data automatically lead to termination of the
warranty. The float-controlled condensate trap model 1277-N / 1278-N is designed for the discharge of condensate from
steam, compressed air and pressure gas systems. Any other usage is not permitted. The manufacturer is not liable for dama-
ge resulting from any other usage. The user or operator bears the risk in this case. This also applies analogously to incorrect
assembly, startup, use and maintenance.
1.2
Warnings and symbols
■
Personal risk due to escaping operating medium because of pressure, temperature and weight. Failure to comply with
these warnings results in the risk of accidents.
■
Follow the instructions in this operating manual.
■
The operator must ensure that this operating manual and, if necessary, other relevant documents are available on site.
■
Only trained or instructed personnel may be assigned to handling this equipment.
■
Any mode of operation that may impair safety must be avoided.
2
General description and usage
2.1
Design of the condensate trap
1
Housing
2
Housing cover
3
Housing gasket
4
Housing screw
5
Float control assembly
6
Control screw
7
Gasket
8
Retaining screw
9
Screw plug
10
Gasket
Picture 3: Model 1278-N
2
7
6
8
5
4
1
3
9
10
Picture 1: Model 1277-N
150
7
6
Picture 2: with special connection
for add. equipment