Installation Guide
1 Introduction
Passive infrared detector «Pyrone-5» (hereinafter, the Detector) is
intended for detecting intrusion into a closed protected space and
generating an alarm message by the relay contacts opening.
The Detector is resistant to the ambient light impact and radio
interference.
The Detector ensures absence of false alarms cased by movement
of pets with weight up to 40 kg if the Detector is installed at the height
not less than 2,3 m.
The Detector is installed directly on a wall or in a corner of a room.
2 Features of the Detector
- Dual-element pyrodetector;
- Spherical lens provides pet immunity as well as absence of
distortions within the detection zone;
- Protection against ingress of insects to the pyrodetector;
- Microprocessor-based signal processing;
- LED indicator mode selection;
- Selection of the detection range and pet immunity (10, 20 or
40 kg pet weight);
- The Detector is powered from power supply unit with rated output
voltage 12 V.
3 Specifications
Table 1
Parameter
Value
Maximum detection range
not less than 10 m
Recommended installation height
2,3 m
Power supply, V DC
8 V… 30 V
Consumed current, not more
15 mA
Output relay contacts
Energized FormA (NC) relay 30mA,
72 V
Alarm message duration, not less than
2 s
Detection zones (DZ)
8 far zones, 4 nearby
Pet immunity
Is chosen by means of «1» and «2»
DIP-switches in accordance with
Table 3
Ambient class
Boreal Climate (background
temperature 15 - 35 °С, relative
humidity 25 - 75 %, air-pressure
86-106 kPa)
Operating temperature
from minus 30 °C to +50 °C
IP rating
IP41
Dimensions, not more than
105х75х56 mm
Weight, not more than
100 g
Average service life, not less than
8 years
The Detector is designed to operate continuously around the clock.
The Detector interference protection provides absence of false
alarms under the following conditions:
- pets movement (in accordance with Table 3);
- background illumination differential;
- convective air flows;
- slow background temperature changing;
- voltage impulses in power-supply circuit;
- electrostatic discharge;
- electromagnetic fields in FM band.
The Detector generates Alarm message under human movement
within the detection zone limits transversally its side border at a speed
range 0.3 – 3 m/s for the distance of 3 m. The Detector is resistant to:
а) transport jolting with the acceleration 30 m/sec
2
with impact fre-
quency from 10 to 120 impacts/sec or 15000 impacts with the same
acceleration;
b) the ambient temperature minus 50 … +50 °С;
c) relative air humidity (95 ± 3) % at the ambient tempe35 °С.
After transportation under the conditions different to exploitation
conditions the Detector shall be ready to operate after a maximum
of six hours.
Average time between failures is not less than 60 000 hours.
Figure 1
8 Installation
Before installing the Detector, remove its cover and the PCB. For
this purpose:
- remove the cover of the Detector;
- push up the holder and remove the printed circuit board (PCB)
(See Figure 2);
- drill the holes (Figure 2) in the base of the Detector case. They will
be used for wire installation and fastening the Detector.
- choose the installation place, mark out and drill the installation holes
in the wall with regard for the position of the holes on the Detector base;
4 Scope of Delivery
Each Detector unit package contains the items listed in Table 2.
Table 2
Name
QNT
Passive infrared detector «Pyrone-5»
Passive infrared detector «Pyrone-5». Installation Guide
1 pc.
1 copy
5 Field of Application
The Detector can be installed in apartments, as well as in shops,
offices, museums and industrial facilities. The Detector may be installed
in premises, that are inhabited by pets weighing up to 40 kg.
6 Choosing an Installation Place
When choosing the Detector installation place, it is advisable to
take note of the fact that the detection zone may be limited by non-
transparent objects (curtains, houseplants, cabinets, bookcases, etc.),
as well as glass and mesh partitions. There must be no windows, air
conditioners, space heaters or heating radiators in the Detector visibility
zone. The presence of furniture items on which an animal may climb
in the detection zone may cause a false alarm.
Recommended installation height – 2,3 m from the floor.
The Detector should be installed far enough from power supply
cables.
7 Detection Pattern
PASSIVE INFRARED DETEC-
TOR
WITH PET IMMUNITY
«PYRONE-5»
0
10 m
Side View
Top View
2,3 m
0
10 m
90
о
Figure 2
Holes for the wall
installation
Holes for corner
installation
Cap screw place of
location
PCB clip
- fasten the base on the chosen place;
- install the PCB on its place;
- put on the cover.
Note
– To exclude false alarms in the pet immunity mode,
the Detector should be installed vertically.
9 Connection
- Fulfill connections in accordance with designation on the PCB
(See Figure 3).
- Set up DIP-switches in accordance with application conditions
(DIP-switches assignment see on the PCB or in Cl.10 of this Instal-
lation Guide).
- Put on the Detector cover.