Rev. 7 of 11.02.2020

v11/v11R/v11.1R

9 Binding with the Control Panel

The Binding procedure is intended for logging of the Detector in 

the control panel (hereinafter, the CP) and transmission of service 
information to it.

Prepare the CP for the Detector logging in accordance to the CP 

manual.

9.1 Open the case cover by releasing the latch with a screwdriver 

(figure 3).

Figure 3

9.2 Install the battery type CR123A (or remove the insulator if the 

battery is already installed).

9.3 LED indicator blinking green displays the Detector readiness for 

the binding procedure. In case the LED indicator does not blink, close 
the «Reset» contacts for a short period.

9.4 After successful binding with the CP, the LED indicator lights 

red for 2 sec.

9.5 The «Binding» procedure is limited to 70 sec. After it expires, 

the Detector switches to the sleep mode.  To resume the «Binding» 
mode, «Reset» contacts should be temporary closed.

9.6 Set the detector sensitivity in accordance with the relevant 

application conditions (Table 4).

       Table 4

Parameter

Pet Immunity

Maximum Range

0

disabled

12 m

1

10 kg

10 m

2

20 kg

10 m

3

40 kg

8 m

10 Choosing Place of Installation

The  Detector  must  be  located  in  the  radio-coverage  zone  of  it’s 

CP. Therefore, it is advisable to appraise quality of communication 
beforehand. The procedure of communication quality appraising is 
described in the chapter №11

 

«Communication Quality Appraising».

When choosing the Detector installation place, it is advisable 

to take note of the fact that the detection zone may be limited by  
non-transparent objects (curtains, houseplants, cabinets, bookcases, 
etc.), as well as glass and mesh partitions. There must be no windows, 
air conditioners, space heaters or heating radiators in the Detector 
visibility zone. The presence of furniture items on which an animal may 
climb in the detection zone may cause a false alarm.

Recommended installation height 

 2.3 m from the floor.

The Detector should be installed at a distance not less than 0.5 m 

from electric cables.

11 Communication Quality Appraising 

Before installing the Detector to it’s place of operation, it is advisable 

to appraise the CP communication quality as follows:

11.1 Prepare the Detector for operation and put it on it’s location 

place with a closed cover;

11.2 Open the Detector case, whereupon the Detector will indicate 

the quality of CP communication.

Table 5

LED Indication

Communication Quality 

Appraisal

Recommendations

LED indicator blinks green 

three times

Excellent

Install the Detector at 

this place

LED indicator blinks green 

two times

Good

LED indicator blinks green 

one time

Communication 

established

Use repeaters of the 

Ladoga RK system

LED indicator blinks red four 

times

No communication

12 Installing the Detector

Before installing the detector, it is necessary to remove the cover 

with the PCB. For this purpose:

- remove the cover of the Detector;
- drill the holes (Figure 2 b) in the base of the Detector case. They 

will be used for fastening the Detector;

- choose the installation place, mark out and drill the installation holes 

in the wall with regard to the position of the holes on the Detector base;

- fasten the Detector base in the chosen place;
- put on the cover. 

Note

 

 To exclude false alarms in pet immunity mode, the Detector 

should be installed vertically.

13 Functional Testing

Start movement across the detection zone. After 3 – 4 steps inside 

the detection zone, the Detector should indicate intrusion by shot-term 
LED lighting red. Wait for 10 s and after it continue movement across 
the detection zone. Under movement absence inside the protected 
area, LED indication should not light.

14 Detector Behavior

14.1 The Detector is powered on and off by installation and removal 

of the main power-supply battery.

14.2 After loss of communication with the CP, the Detector will 

continue to search for the CP. If the CP is disabled for a long time, it 
is recommended to power off the Detector (see Cl. 14.1).

14.3. It must be taken into account that in case of the Detector 

operation 5 °C to minus 20 °C temperature range, the battery 
life may be less than 5 years.

ATTENTION!

 The Detector must be checked at least annually in 

order to test it’s performance.

15 Storage and Transportation 

15.1 The Detectors in their original packaging are resistant to: 
- transport jolting with the acceleration up to 30 m/sec

2

 at impact 

frequency range

 

from 10 to 120 per minute or 15 000 strikes;

- ambient temperature range minus 50 ... +50 °С;
- relative air humidity (95 ± 3) % at a tempe35 °С.
15.2 The Detectors in original package may be transported by 

any means of transportation in closed vehicles over any distances in 
compliance with the existing shipping rules concerning the respective 
means of transportation.

15.3 After transportation under the conditions different to 

exploitation conditions the Detectors shall be ready to operate after 
a maximum of six hours.

15.4 During storage period lithium batteries should be removed from 

the holders or isolators should be installed between a battery “+” and 
a holder.

The storage premises should not contain any current-conducting 

dust, acid and alkali fumes, or corrosive or destroying insulation gases.

16 Manufacturer’s Guarantees

16.1 The Manufacturer guarantees conformity of the Detector to 

it’s Technical Specifications if conditions of transportation, storage, 
assembling and operation are observed. The guaranteed storage 
period is 63 months since the date of manufacturing the Detector.

16.2 The guaranteed period of operation is 60 months since the date 

of commissioning within the storage period guaranteed.

16.3 The Detectors that are found to non-conforming to their 

Technical Requirements shall be repaired by the Manufacturer, 
provided that the installation and operation rules have been complied 
with.

Note 

 Warranty obligations are not applied to the power-supply 

batteries.

17 Packing Certificate 

Wireless passive infrared detector «Pyrone-4RK» manufactured in 

accordance with current technical documentation is classified as fit 
for operation and is packed by «RIELTA» JSC.