4
1
3
2
7
11
8
9
10
5
6
12
13 14
15
17
18
16
Installation Guide
PASSIVE INFRARED
LONG RANGE
DETECTOR
«FOTON-15A»
1 General Information
Passive infrared long range detector «Foton-15A» (hereinafter, the
Detector) is designed for detecting intrusion into a protected space and
generating an alarm message by consumption current value changing.
The Detector can be installed in heated or unheated spaces having
different application: in museums, offices, cottages, flats, shops, as
well as in warehouses, garages, hangars.
The Detector generates three types of messages:
- «Norm»;
- «Alarm»;
- «Tamper».
The Detector provides digital temperature compensation of it’s
detectability.
2 Features
- Dual-element pyrodetector;
- Power supply by the alarm loop (AL);
- Immunity to insect’s intrusion to the pyrodetector;
- Swivel bracket (supplied) providing ease of Detector installation
and detection zone repositioning;
- LED indicator for the Detector operation visual control. LED
indication is switched ON or disabled by applying a jumper to one of
the «IND» wafer position («ON» or «OFF»);
- Two modes of alarm messages generation: «Short-circuit» (SC)
(by increasing current consumption value) and «Open-circuit» (OC)
(by decreasing current consumption value). Required operation mode
is assigned either by removal SC jumper, or by applying OC jumper to
the «OC» wafer position.
3 Principal Technical Characteristics
Table 1
Parameter
Value
Detection zone types
long range
Maximum detection range, not less than
20 m
Detection angle in horizontal plane
6
0
Mounting height
2.3 m
Detected speed range
0.3 – 3 m/sec
Alarm message duration, not less than
2 sec
Warm-up time, not more than
60 sec
Power supply
8 – 72 V DC
Current consumption in
«
NORM
»
mode:
SC mode, not more than
OS mode, adjustable
0.1 mА
2 ... 15 mА
Operation temperature
minus 30 ... +50
0
С
Relative humidity under 25 °С without moisture
condensation
95 %
IP rating
IP41
Dimensions, maximum
126 х 70 х 55 mm
Mass, not more
0.15 kg
4 Detection Zone Pattern
5 Scope of delivery
Each Detector unit package contains the items listed in Table 2.
Table 2
Name
QNT.
Passive infrared long range detector «Foton-15A»
Swivel bracket
Screw 3-3х30.016
Passive infrared long range detector «Foton-15A».
Installation Guide
1 pc.
1 pc.
2 pcs.
1 copy
6 The Detector Design
The Detector comprises base, printed circuit board (PCB) and a
cover. Swivel bracket is included in scope of delivery.
1 – bush;
2 – nut;
3 – sphere;
4 – swivel bracket case;
5 – openable holes for wiring;
6 – openable hole for fastening to swivel bracket;
7 – screw;
8 – openable holes for corner mounting;
9 – opening for cover holder;
10 – PCB fixing arm;
11 – openable holes for wall mounting;
12 – leading-in sockets for AL plugging;
13 – LED indicator;
14 – LED indication ON/OFF jumper;
15 – Operating modes changeover SC/OP jumper;
16 – potentiometer for current consumption adjustment;
17 – pyrodetector;
18 – case ramper.
Figure 2 – Design of the Detector
7 Choosing Place of Installation
When choosing the Detector installation place, take note of the fact
that the detection zone may be limited by non-transparent objects
(curtains, houseplants, cabinets, bookcases, etc.), as well as glass and
mesh partitions. There must be no windows, air conditioners, space
heaters or heating radiators in the Detector visibility range.
When mounting choose the Detector orientation in such a position,
that any potential directions of intrusion should cross sensitive zones
of the Detector.
Power supply and alarm loops should be wired far enough from load
cables. There must be no animals or birds in the protected space.
8 The Detector Installation
Choose the place of installation (Cl. 7):
- unfasten the latch through the opening, which is situated downside
the detector case by means of screwdriver and put off the detector
cover (Figure 2);
- when installing the detector without swivel bracket it is necessary
to put off the PCB by means of pushing up it’s fixing arm;
- drill the holes in the base of the detector for wiring and fastening
the detector;
- choose the place of installation, mark the places for mounting
holes with the regard to detector base (or swivel bracket) openings;
- drill the holes in the wall with regard to market places;
- pass the wire through the mounting holes in the base, leaving
several centimeters of installation wire for it’s fastening inside the case;
- fix the base of the detector case on the wall (swivel bracket) at
the chosen place. In case of swivel bracket using, unscrew the cap
screw from the swivel bracket sphere. Fit the square bulge of the swivel
Figure 1 – Detection Zone Pattern
Structure of any
sensitivity zone
6
0
20 m
20 m
2.3 m
1 m