Note 

 

In this mode the alarm message generated in compliance 

with the adjusted sensitivity mode is not displayed by LED indication. 

In the motion absence in the detection zone the LED indicator must 

not light. Upon the expiry of 5 minutes check procedure, the detector 
transfers to normal mode. If DIP-switch is in position «2» – «ON», 
generation of alarm message is displayed by LED-indicator lighting 
for the 3 sec period. 

2) Sensitivity mode adjustment

DIP-switches position: «1» – «ON», «2» – «ON». The mode is intended 

for detector sensitivity appraisal (the distance, which is possible to pass 
through the detection zone up to the point, where the movement is 
detected, and alarm message is generated). The LED indicator blinks 
for 0.25

 

period under the condition of detection zone beam crossing, 

and for 3 sec during alarm message generation.

Stop after each alarm message generation and wait until the LED 

indicator is disabled for 8 – 10 sec and more, then continue movement 
through the detection zone. 

Note 

– If the detector does not identify movement within the 

detection zone, it is necessary to change detector position by means 
of swivel bracket (in case of wall mounting the horizontal turning angle 
of the detector on swivel bracket – ±45

0

, vertical – not less than 20

0

).

12 LED Indication Disabling

For the detector operation masking, the LED indication disabling 

mode is available. DIP-switch «2» – «OFF». 

In this mode the LED indicator is lighting for only one minute after 

detector energizing, as well as in «Alarm Memory» and «Malfunction» 
modes. 

13 Alarm Memory Mode

DIP-switch «3» – «ON». The LED indicator is lighting green in  

5 min after alarm memory generation. Duration of indication – 15 min. 

14 Self-Test Mode

The detector provides self-testing of the following parameters: 

amplifier operability, input voltage, ambient temperature. If the 
ambient temperature range is close to 36 

о

С, the sensitivity threshold 

changes, the level of sensitivity is automatically adjusted, what leads 
to detectability enhance (temperature compensation). 

In case of self-test failure (amplifier malfunction, voltage drop lower 

than 9

-1

 V, ambient temperature out of permissible temperature range), 

«Malfunction» message is generated by opening the relay output 
contacts repeated by alternate LED indicator blinking red and green.

«Malfunction» message duration – 15 min. After elimination of 

malfunction, the detector turns to self-test mode.

ATTENTION!

 The detector must be checked at least once annually 

for functional testing.

15 Storage and Transportation 

The detectors in their original packing may be shipped by any 

transport means in covered vehicles (in railway, cars, trucks, sealed 
heated compartments of aircraft, ship cargo holds, etc). The storage 
room should be free from current-conducting dust, acid vapors, alkali 
and gases that cause corrosion and destroy insulation. 

16 Manufacturer’s Guarantees

The  Manufacturer  guarantees  conformity  of  the  detector  to  it’s 

Technical Specifications if conditions of transportation, storage, 
assembling and operation are observed. The guaranteed storage 
period is 63 months since the date of manufacturing the detector.

The guaranteed period of operation is 60 months since the date of 

commissioning within the storage period guaranteed.

The detectors that are found to non-conforming to it’s Technical 

Requirements shall be repaired by the Manufacturer, provided the 
installation and operation rules have been complied with.

17 Acceptance and Packing Certificate

Passive infrared detector 
 «Foton-10M»
 «Foton-10M-01»

batch №___________________

 manufactured in accordance with current technical documentation 

is classified as fit for operation and is packed by «RIELTA» JSC.

Person responsible for acceptance and packing 

QC representative_________________    __________________.

                                                       

 Date, month, year

Figure 3

Table 3

Mode

DIP-switch

DIP-switch Position

«ON»

«OFF»

Sensitivity

«1»

TEST

«SENS» (Sensitivity 

determination)

«ZONE» (Detection 

zone determination)

Testing

«2»

IND

«IND» (ON)

«OFF» (LED indicator is 

disabled)

Indication 

Disabling

«3»

MEM

«MEM» (Alarm 

memory ON)

«OFF» (Alarm memory 

OFF)

9 LED Indication

The Led indicator located at the front of the cover displays the 

detector mode.

Table 3

Message

Led  Indicator  

Color

LED Indication State

«Warm-up Time»

RED

Blinking with 1 Hz frequency during 

60  sec

«Norm»

-

LED Indication is OFF

«Alarm»

RED

LED Indication is on during 3 sec

«Malfunction»

RED

GREENN

Alternate switching during 15 min

«Alarm Memory»

GREENN

LED Indication is ON during 15 min

10 Functional Check

After energizing of the detector, the self-testing process is realized 

during one minute. It ensures control of the following parameters: 
input voltage, ambient temperature, operation capacity of the amplifier 
channel. During the procedure, the LED indicator is blinking red 
(irrespective of the DIP-switch «2» position), relay contacts are opened.

11 Testing Mode

Upon the expiry of the warm-up time, the detector turns to standby 

mode and is able to generate alarm message. During the process 
within 5 minutes it is possible to check the detector parameters. The 
checking procedure provides two modes.

1) Detection zone position location

DIP-switches position:

 

«1» – «OFF», «2» – «ON». The mode is 

intended for each beam of detection zone positioning in the secured 
premises. Under the condition of each beam crossing the LED indicator 
switches for 0.25 sec. Optimized speed of movement at maximal 
distance – 0.5 m/sec.

Rev. 2 of 26.01.15

№00108

Circuit

Cont.

1
2
3
4
5
6

+12V

-12V

AL
AL

Taper
Taper

To power 
source

R

term1

Detector

To CP

а)

Taper-
control 
AL

Security 
AL

R

term1

Circuit

Cont.

To power 
supply unit

R

term1

Detector

1
2
3
4
5
6

+12V

-12V

AL
AL

Taper
Taper

«RIELTA» JSC, www.rielta.ru,
Chapaeva Str. 17, Saint Petersburg, Russia, 197101, [email protected],

Tel./fax. +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected].

b)

Table 2

Installation height

Detector tilt

Distance to the wall, L, mm

2 – 3 m
3 – 4 m
4 – 5 m



35
28
22

Notes:

1 The tilt and the distance values listed in Table 2 are reference 

data. Final distance L value is defined in accordance with the test 
pass results.

2 The detector base turning horizontally would change the distance 

(L) from the wall to the inclined detector base. The change depends 
on the turning angle. Thus, it is necessary to adjust the detector tilt.

8 Connection

- The terminals for the detector connection are located at the top 

of PCB.

- Fulfill connections in accordance with the Figure 3a (for single 

alarm loop connection) and with Figure 3b (with alarm loop and  tamper 
connection).

- Install the DIP-switches in accordance with application conditions.

- Put the detector cover on it’s place.

- Install DIP-Switches «1», «2», «3» in accordance with application 

conditions.

- Put the detector cover on it’s place.