6 PROGRAMMING
- In order to access programming mode, press the
summer/winter Button (3) for 4 seconds.
00
0
3
Fig. 46
The display will flash while waiting for the password to be
entered.
There are 3 different levels:
- Installer
- Factory
- Monitor
6 1 Installer Level
- Access programming mode by pressing the summer/
winter Button (3) for 4 seconds
- Press the "+" and "-" heating Buttons (2) to enter the
Installer password
"03"
- Press the summer/winter Button (3) once to confirm
03
0
2
3
Fig. 47
If the password is incorrect, the system will return to stand-
ard mode.
The installer level has been accessed, the user will be able
to view and modify certain parameters. The first digit will
display a letter followed by the parameter number.
- Press the "+" and "-" heating Buttons (2) to scroll
through the parameters
0 I
P
2
Fig. 48
The selected parameter number will appear in alternation
with the set value. The value assigned to the selected pa-
rameter is shown in the two digits on the right.
- Press the "+" and "-" domestic hot water Buttons (4) to
modify the parameter's value until the desired value
is obtained
The new value will begin to flash
55
P
4
2
3
Fig. 49
- Press the summer/winter Button (3) to confirm, or else
the"+" and "-" heating Buttons (2) to cancel
6 2 Factory Level
Everything is the same as in the previous case, but with a
factory password that allows the user to access the pro-
tected parameters.
6 3 Monitor Level
The Monitor level allows the user to view the values as-
signed to the probes one at a time (see the table below).
- Press the summer/winter Button (3) for 4 seconds
- Press the summer/winter Button (3) again
60
i
2
3
Fig. 50
The first value, which corresponds to the delivery tempera-
ture, will appear on the display.
- Press of the "+" and "-" heating Buttons (2) to scroll
through all the available values
Displayed values
Digit 1
Digit 2-3
CH flow temperature
1
Value
Return temperature
2
Value
Domestic hot water temperature
3
Value
Outdoor sensor temperature
4
Value
Flue gas temperature
5
Value
2nd circuit temperature
6
Value
Fan speed
7
Value
Ionization
8
Range
70-100