Riello SEP1000 Скачать руководство пользователя страница 2

 

I

NTRODUCTION

 

 
Congratulations on purchasing a 

UPS Sentinel Pro 

product and welcome to 

Riello UPS

! To use the support service 

offered by 

Riello UPS

, visit the site 

www.riello-ups.com 

 

 
The company is highly specialised in the development and production of uninterruptible power supplies (UPSs). 
The UPSs in this series are high-quality products, carefully designed and manufactured in order to ensure the highest 
levels of performance. 
 
 
This device can be installed by anyone on the condition that he/she has 

READ THE USER AND SAFETY MANUAL 

CAREFULLY. 
 
The UPS and the Battery Box internally generate DANGEROUS electrical voltages. All maintenance operations 
must be carried out SOLELY by qualified operators. 
 

 
This manual contains detailed instructions for using and installing the UPS and the Battery box. 

For information about using and making the most of the performance of your device, please keep hold of the CD 
containing this manual and read it carefully before operating the equipment.

 

 
 
 
 

E

NVIRONMENTAL 

P

ROTECTION

 

 
In the development of its products, the company devotes abundant resources to analysing the environmental aspects. 
All our products pursue the objectives defined in the environmental management system developed by the company in 
compliance with applicable standards. 
 
 
No hazardous materials such as CFCs, HCFCs or asbestos are used in this product. 
 
 
When evaluating packaging, the choice of material has been made favouring recyclable materials. 
For correct disposal, please separate and identify the type of material of which the packaging is made in the table below. 
Dispose of all material in compliance with applicable standards in the country in which the product is used. 
 
 
 

D

ESCRIPTION

 

M

ATERIAL

 

Box Cardboard 

Packaging corner  

Stratocell 

Protective bag  

Polythene 

Accessories bag 

Polythene 

 
 
 

D

ISPOSING OF THE PRODUCT

 

 
The UPS and the Battery Box contain electronic cards and batteries which are considered TOXIC and HAZARDOUS 
waste. When the product reaches the end of its operating life, dispose of it in accordance with applicable local legislation. 
Disposing of the product correctly contributes to respecting the environment and personal health. 
 
 
 
 

 

© 

The reproduction of any part of this manual, in whole or in part, is forbidden without the prior consent of the manufacturer. 
In order to make improvements, the manufacturer reserves the right to modify the product described at any moment and without 
notice. 

Содержание SEP1000

Страница 1: ......

Страница 2: ...nvironmental aspects All our products pursue the objectives defined in the environmental management system developed by the company in compliance with applicable standards No hazardous materials such...

Страница 3: ...ACITY 11 USE 12 CONNECTIONS AND SWITCHING ON FOR THE FIRST TIME 12 SWITCHING ON FROM THE MAINS 12 SWITCHING ON FROM THE BATTERY 12 SWITCHING OFF THE UPS 12 DISPLAY PANEL MESSAGES 13 UPS STATUS MESSAGE...

Страница 4: ...4 TROUBLESHOOTING 20 ALARM CODES 22 FAULT 22 LOCK 23 TECHNICAL DATA 24...

Страница 5: ...or more autonomy expansion units known as BATTERY BOXES optional accessories with the same dimensions and aesthetic line as the UPS alongside it The ER model UPSs fitted with upgraded battery charger...

Страница 6: ...000VA 1000VA ER model Display Cooling fans Multipurpose buttons Battery expansion connector ON OFF switch IEC 10A output socket RS232 communication port and contacts IEC 10A input plug USB communicati...

Страница 7: ...232 communication port and contacts IEC 16A output socket only for 3000VA models USB communication port IEC 10A output socket Slot for communication cards IEC 16A input plug Cooling fans IEC 10A input...

Страница 8: ...t Battery charge indicator ON button Load level indicator STAND BY button Configuration area Regulation operation Maintenance request Mains operation Timer Battery operation Measurement display area L...

Страница 9: ...outs The number of batteries contained can vary according to the type of UPS for which the BATTERY BOX is intended It is therefore necessary to take great care to ensure that the battery voltage of th...

Страница 10: ...necessary to check the contents The package must contain UPS Schuko power cable IEC 10A IEC 16A for 3000VA models only 2 IEC 10A connection cables IEC 16A male plug For 3000VA models only USB cable RS...

Страница 11: ...N THE BACK OF THE DEVICE It is possible to connect more than one Battery Box in order to achieve any level of autonomy without mains power Connect any Battery Boxes in a cascade as shown in the figure...

Страница 12: ...ing modes paragraph to set the required mode For advanced UPS configurations execute the software UPSTools which can be downloaded from the web site www riello ups com SWITCHING ON FROM THE MAINS 1 Pr...

Страница 13: ...at regular 4 second intervals Flashing Low battery pre alarm Indicates that battery autonomy is coming to an end In this condition the UPS emits a beep at regular 1 second intervals Fixed Indicates th...

Страница 14: ...ng alarm Some examples are shown below GRAPHIC EXAMPLE 1 DESCRIPTION GRAPHIC EXAMPLE 1 DESCRIPTION Mains voltage Battery charge percentage Mains frequency Total battery voltage UPS output voltage Appl...

Страница 15: ...taining the output frequency synchronised to the mains within a configurable range Outside this range the UPS output de synchronises from the mains supply moving to the nominal frequency in this condi...

Страница 16: ...of the status of the UPS via USB or RS232 For a list of possible configurations available to the user refer to the UPS Configuration paragraph INSTALLATION OPERATIONS 1 Connect one of the UPS s commun...

Страница 17: ...Disabled without input output synchronisation Power off due to minimum charge Automatic UPS power off in battery operation mode if the charge is lower than 5 Disabled Enabled Disabled Autonomy limit...

Страница 18: ...for operation in ECO mode Low 200V High 253V Low 180 220 in 1V steps High 240 264 in 1V steps Intervention sensitivity for ECO Selects the intervention sensitivity during operation in ECO mode Normal...

Страница 19: ...S refer to the manual provided 2 TXD 3 RXD 4 Programmable input default disabled 5 GND 6 Power supply DC Imax 20mA 7 Programmable input default disabled 8 Programmable output default low battery pre a...

Страница 20: ...he STAND BY OFF emergency power supply mode in fact only powers the loads in the event of a blackout NO CONNECTION TO THE LOAD Check the connection to the load THE UPS IS OPERATING FROM THE BATTERY DE...

Страница 21: ...rs again call the support centre THE BUZZER SOUNDS CONTINUOUSLY AND THE DISPLAY SHOWS ONE OF THE FOLLOWING CODES F04 L04 THE TEMPERATURE OF THE DISSIPATORS INSIDE THE UPS IS TOO HIGH Check that the te...

Страница 22: ...0 C A54 Load percentage greater than the user threshold set A61 Replace batteries A62 Batteries missing or Battery Box missing or not connected A63 Waiting for battery charging Alarms these are more...

Страница 23: ...ed for locks due to serious persistent overloads and short circuits CODE DESCRIPTION L02 Control card is not inserted correctly L03 Incorrect auxiliary power supply L04 Dissipator over temperature L05...

Страница 24: ...the bypass after 2 seconds locks after 4 seconds Bypass line not available locks after 4 seconds Overload load 150 Bypass line available activates the bypass instantly locks after 1 second Bypass line...

Страница 25: ...036 NPA JSEP036 NPM JSEP072 NPA JSEP072 NPM Nominal battery voltage Vdc 36Vdc 72Vdc Dimensions W x D x H mm 158 x 422 x 235 190 x 446 x 333 Weight kg 14 21 27 41 The symbol replaces an alphanumeric co...

Страница 26: ...0MNSEP700RUENUC...

Отзывы: