background image

18 

 

FUNCTION 

DESCRIPTION 

DEFAULT 

POSSIBLE CONFIGURATIONS 

 

 

Bypass voltage 

thresholds 

Selects the permitted 
voltage range for switching 
to the bypass  

Low: 180V 
High: 264V 

  Low:  180 - 200 in 1V steps 

  High:  250 - 264 in 1V steps 

 

 

 

 

Bypass voltage 
threshold for ECO 

Selects the permitted 
voltage range for operation 
in ECO mode  

Low: 200V 
High: 253V 

  Low:  180 - 220 in 1V steps 

  High:  240 - 264 in 1V steps 

 

 

 

 

Intervention 

sensitivity for  

ECO 

Selects the intervention 
sensitivity during operation 
in ECO mode  

Normal 

 Low  

 Normal 

 High 

 

 

 

 

Power-on delay 

Waiting time for automatic 
switching back on after 
mains power returns 

5 sec. 

 Disabled 

  (1 - 255) sec.  in 1 sec steps 

 

 

 

 

Remote power-

on/off function 

Selects the function 
associated with the RS232 
connector. 

Disabled 

 Disabled 

 Remote ON 

 Remote OFF 

 Remote ON/OFF 

 
 

Содержание SEP1000

Страница 1: ......

Страница 2: ...nvironmental aspects All our products pursue the objectives defined in the environmental management system developed by the company in compliance with applicable standards No hazardous materials such...

Страница 3: ...ACITY 11 USE 12 CONNECTIONS AND SWITCHING ON FOR THE FIRST TIME 12 SWITCHING ON FROM THE MAINS 12 SWITCHING ON FROM THE BATTERY 12 SWITCHING OFF THE UPS 12 DISPLAY PANEL MESSAGES 13 UPS STATUS MESSAGE...

Страница 4: ...4 TROUBLESHOOTING 20 ALARM CODES 22 FAULT 22 LOCK 23 TECHNICAL DATA 24...

Страница 5: ...or more autonomy expansion units known as BATTERY BOXES optional accessories with the same dimensions and aesthetic line as the UPS alongside it The ER model UPSs fitted with upgraded battery charger...

Страница 6: ...000VA 1000VA ER model Display Cooling fans Multipurpose buttons Battery expansion connector ON OFF switch IEC 10A output socket RS232 communication port and contacts IEC 10A input plug USB communicati...

Страница 7: ...232 communication port and contacts IEC 16A output socket only for 3000VA models USB communication port IEC 10A output socket Slot for communication cards IEC 16A input plug Cooling fans IEC 10A input...

Страница 8: ...t Battery charge indicator ON button Load level indicator STAND BY button Configuration area Regulation operation Maintenance request Mains operation Timer Battery operation Measurement display area L...

Страница 9: ...outs The number of batteries contained can vary according to the type of UPS for which the BATTERY BOX is intended It is therefore necessary to take great care to ensure that the battery voltage of th...

Страница 10: ...necessary to check the contents The package must contain UPS Schuko power cable IEC 10A IEC 16A for 3000VA models only 2 IEC 10A connection cables IEC 16A male plug For 3000VA models only USB cable RS...

Страница 11: ...N THE BACK OF THE DEVICE It is possible to connect more than one Battery Box in order to achieve any level of autonomy without mains power Connect any Battery Boxes in a cascade as shown in the figure...

Страница 12: ...ing modes paragraph to set the required mode For advanced UPS configurations execute the software UPSTools which can be downloaded from the web site www riello ups com SWITCHING ON FROM THE MAINS 1 Pr...

Страница 13: ...at regular 4 second intervals Flashing Low battery pre alarm Indicates that battery autonomy is coming to an end In this condition the UPS emits a beep at regular 1 second intervals Fixed Indicates th...

Страница 14: ...ng alarm Some examples are shown below GRAPHIC EXAMPLE 1 DESCRIPTION GRAPHIC EXAMPLE 1 DESCRIPTION Mains voltage Battery charge percentage Mains frequency Total battery voltage UPS output voltage Appl...

Страница 15: ...taining the output frequency synchronised to the mains within a configurable range Outside this range the UPS output de synchronises from the mains supply moving to the nominal frequency in this condi...

Страница 16: ...of the status of the UPS via USB or RS232 For a list of possible configurations available to the user refer to the UPS Configuration paragraph INSTALLATION OPERATIONS 1 Connect one of the UPS s commun...

Страница 17: ...Disabled without input output synchronisation Power off due to minimum charge Automatic UPS power off in battery operation mode if the charge is lower than 5 Disabled Enabled Disabled Autonomy limit...

Страница 18: ...for operation in ECO mode Low 200V High 253V Low 180 220 in 1V steps High 240 264 in 1V steps Intervention sensitivity for ECO Selects the intervention sensitivity during operation in ECO mode Normal...

Страница 19: ...S refer to the manual provided 2 TXD 3 RXD 4 Programmable input default disabled 5 GND 6 Power supply DC Imax 20mA 7 Programmable input default disabled 8 Programmable output default low battery pre a...

Страница 20: ...he STAND BY OFF emergency power supply mode in fact only powers the loads in the event of a blackout NO CONNECTION TO THE LOAD Check the connection to the load THE UPS IS OPERATING FROM THE BATTERY DE...

Страница 21: ...rs again call the support centre THE BUZZER SOUNDS CONTINUOUSLY AND THE DISPLAY SHOWS ONE OF THE FOLLOWING CODES F04 L04 THE TEMPERATURE OF THE DISSIPATORS INSIDE THE UPS IS TOO HIGH Check that the te...

Страница 22: ...0 C A54 Load percentage greater than the user threshold set A61 Replace batteries A62 Batteries missing or Battery Box missing or not connected A63 Waiting for battery charging Alarms these are more...

Страница 23: ...ed for locks due to serious persistent overloads and short circuits CODE DESCRIPTION L02 Control card is not inserted correctly L03 Incorrect auxiliary power supply L04 Dissipator over temperature L05...

Страница 24: ...the bypass after 2 seconds locks after 4 seconds Bypass line not available locks after 4 seconds Overload load 150 Bypass line available activates the bypass instantly locks after 1 second Bypass line...

Страница 25: ...036 NPA JSEP036 NPM JSEP072 NPA JSEP072 NPM Nominal battery voltage Vdc 36Vdc 72Vdc Dimensions W x D x H mm 158 x 422 x 235 190 x 446 x 333 Weight kg 14 21 27 41 The symbol replaces an alphanumeric co...

Страница 26: ...0MNSEP700RUENUC...

Отзывы: