GENERAL INFORMATION

GENERAL INFORMATION

PRECAUTIONS

The operation of any appliance that uses electrical power de-

mands that a number of fundamental safety precautions be re-

spected. In particular:

 

0

Never attempt to install the system without using suitable 

personal  protection  equipment  and without  following  all 

applicable occupational safety standards.

 

0

It is forbidden to touch the device while barefoot or with 

wet or moist body parts.

 

0

It is forbidden to perform any technical or cleaning opera-

tions before having disconnected the device from its elec-

trical power supply, by setting the system's main switch to 

"off".

 

0

It is forbidden to pull, detach, or twist the electrical cables 

protruding from the device, even if it is disconnected from 

its electrical power supply.

 

0

Do not expose the storage cylinder to the elements. It is not 

designed for use outdoors.

 

0

If solar plant pressure decreases, it is forbidden to top up 

with only water as there is a danger of freezing and over-

heating.

 

0

Do not use connections or safety devices or fittings (expan-

sion vessels, pipes, insulation) that are not specifically de-

signed and tested for use in solar water heating systems.

 

0

Do not allow children or infirm persons to operate the sys-

tem unsupervised.

 

0

Do not dispose of packaging material into the environment, 

or leave it within the reach of children, since it can become 

a potential hazard. Dispose of packaging material in com-

pliance with applicable legislation.

DESCRIPTION OF THE APPLIANCE

The solar station 

RSS

 allows transferring sun power from collec-

tors to a storage system.

The solar station 

R

 is enclosed in an EPP (Polypropylene foam) 

insulating casing and is designed to perform:

 

− system flushing

 

− system filling and emptying

 

− circulator removal.

The key components are:

 

− high-efficiency  circulator  with  variable  speed  (already 

hard-wired)

 

− shut-off valves as non-return valves

 

− thermometers

 

− pressure gauge

 

− fitting for connection to a solar expansion tank

 

− suitable safety device, as indicated in paragraph "Safety 

and control devices".

Version MRS includes a solar regulator and temperature probes 

as standard (to be connected). Version MR includes a terminal 

strip for interface connection to an external regulator able to 

manage one PWM pump.

 

9

The integrated circulator can be managed only through 

PWM signal and does not need a flow control. Therefore, 

to choose the proper solar regulator to match version MR 

please refer to paragraph "Electric connections and wiring 

diagrams”.

SAFETY AND CONTROL DEVICES

Solar station safety and setting are achieved thanks to:

 

− Safety valve with trigger pressure set at 6 bar;

 

− Solar Regulator (if equipped) for circulator management/

control. Manages 9 system diagrams that can be select-

ed. Refer to the specific manual for further details.

IDENTIFICATION

The solar stations by 

R

 can be identified by:

Serial number plate

This specifies the serial number and model.

Cod. :    

Via Ing. Pilade Riello 7 - 37045 Legnago (VR) - Italia

RIELLO  S.p.A.

TqelRI100

Serial N.° :    

Mod. :    

MAX  

  W

IP  

Pmax

bar

Made in Italy

 

9

If these plates or any other means of clearly identifying 

the product are defaced, removed or lost, proper instal-

lation and servicing may be rendered difficult.

In case of loss, request a duplicate to 

R

 Technical Assistance 

Service.

Содержание RSS MR

Страница 1: ...cod 20124605 rev 2 10 2017 1 2 3 4 5 0 6 RSS MR MRS EN INSTALLATION AND MAINTENANCE MANUAL ...

Страница 2: ...rformed by a qualified heating engineer 9 9This instruction manual is an integral part of the product It must be kept safe and must ALWAYS accompany the product even if it is sold to another owner or transferred to another user or to another installation If you lose this manual or der a replacement immediately Keep the product purchase documents to be presented to the R authorised Technical Assist...

Страница 3: ...allows transferring sun power from collec tors to a storage system The solar station R is enclosed in an EPP Polypropylene foam insulating casing and is designed to perform system flushing system filling and emptying circulator removal The key components are high efficiency circulator with variable speed already hard wired shut off valves as non return valves thermometers pressure gauge fitting fo...

Страница 4: ... temperature gauge 5 Insulation 6 Tap A for system filling draining 7 Pump 8 Pressure gauge 9 Tap B for system filling draining 10 Safety valve 6 bar 11 Fixing bracket 12 Solar controller 13 Display 14 Multidirectional joystick 15 Terminal strip M Solar circuit outlet Inlet of heat transfer fluid coming from solar collector R Solar circuit return Outlet of heat transfer fluid towards solar collect...

Страница 5: ... resistance exchanger solar collectors and pipes at the maximum flow rate conditions provided Installation 8 UNPACKING THE PRODUCT Package content 1 2 5 6 3 8 7 4 1 Solar station 2 Bag containing 3 probes 1 5 m long only for version MRS 3 Solar controller only for version MRS 4 Terminal strip only for version MR In a plastic bag the following material is also supplied 5 Instruction manual 6 Instru...

Страница 6: ...ransfer fluid towards solar storage system RB Storage system return 3 4 M Inlet of heat transfer fluid from solar storage system SV Safety valve drain VE Expansion tank fitting E Solar expansion tank not supplied T Safety valve outlet pipe not supplied Connect delivery fittings M and return fittings R found at the top of the solar station to the solar plant Connect delivery fittings MB and return ...

Страница 7: ...is not responsible for any damage caused by failure to earth connect the device and failure to comply with what is indicated in the wiring diagrams Refer to the manual supplied with the solar controller for de tails of all electrical connections programming etc Version with solar regulator MRS CN4 CN3 M4 M3 M2 M1 3 2 1 4 5 6 CN6 F AE 230V 50Hz AN GD U1 U2 N L B A S6 S4 S5 S3 S2 S1 S1 S2 S3 C S4 AE...

Страница 8: ...culator supplied with version MR needs a PWM signal con trol with the characteristics below REG MO 230 CONTROL PUMP AE 230V 50Hz C N GND PWM L PE L N PE AE Power supply connections to be made by the installer REG Generic solar regulator C Circulator with PWM control MO Terminal strip MO 230 CONTROL PUMP AE 230V 50Hz C N GND PWM L PE L N PE EVOSOL AE Power supply connections to be made by the insta...

Страница 9: ... power Symbol Value PWM input frequency f 100 4000 Hz Consumption in stand by 1 W High voltage level of input signal UiH 4 24 V Low voltage level of input signal UiL 1 V Input signal current IiH 10 mA Input Duty cycle PWM 0 100 14 SYSTEM FLUSHING Before filling the system with mixture of water and glycol it is necessary to flush the pipes of the solar system to eliminate all residues of fluid or s...

Страница 10: ...ture Mixture of glycol and water 1 2 3 4 5 0 6 B A VM VR PC PC Heat transfer fluid filling pump To fill the system proceed as follows Connect the filling pump PC as shown Turn handle on valve VR clockwise Open taps A and B on the return tube Open manual degassing tap and any bleeder valve lo cated at the highest points of the system and keep them open throughout the filling procedure Pump the heat...

Страница 11: ... data sheet supplied with the glycol 17 2 Disassembling the circulator 9 9Remove the circulator when system has cooled down Before removing circulator C Cut power off to the solar station and to the connected integration system by setting the system s main switch and the device s main switch to OFF Disconnect circulator power by removing connectors D and E Move away any wiring and electric devices...

Страница 12: ...llo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice ...

Отзывы: