18
ALARMS AND WORKING STATUS
Explanation of status LEDs displayed on WiFi Box.
LED
green
LED
red
Status
F05
Relè = bridged
(sonly with ON/OFF installation)
F1
Relè = open
(only with ON/OFF installation)
ON
OTBus connection = OK
(OT connection)
ON
F01
Boiler alarm
(OTBus connection)
F05
F1
ON
ON
Network or RF error
F05
F05
WPS mode in progress (press and
hold WPS button) – wait WPS signal
*
F05
WPS signal detected*
F05
F05
Smartlink mode in progress (press
once Smartlink button)*
F1
F1
RF encoding in progress (press and
hold the WiFi LED button)
* Only for WiFi Box
LED
ON
= fixed ON
F05
= flashing fast (0,5 secs)
F1
= flashing slow (1 secs)
Alarm codes indicated on the
Ricloud
display and
suggested corrective actions.
Alarm
Description
Err
Temperature sensor broken.
(not reparable - see Ricloud Instruction
Manual)
E82
Radio frequency error
(Check batteries/distance - see Ricloud
Instruction Manual)
E83
NO OTBus comunication
(Check connections - see Ricloud Instruction
Manual)
E84
Hardware problems
(not reparable, see Ricloud Instruction
Manual)
A01…99
Boiler alarm
(see boiler manual)