3  PRODUCT RECEIPT

On receipt of your boiler it is suggested that you visually check 

for external damage to the shipping package. 
If the package is damaged, make a note to that effect on the 

Bill of Lading when signing for the shipment. 

 

− Remove the boiler from the shipping packaging. 

 

− Report any damage to the carrier immediately. 

 

− On occasion, items are shipped loose. 

 

− Be sure that you receive the correct number of packages as 

indicated on the Bill of Lading. 

 

− Claims for shortages and damages must be filed with the 

carrier by consignee.

 

− Permission  to  return  goods  must  be  received  from

 the 

manufacturer or your local 

R

 distributor prior to shipping. 

Goods returned to the factory without an authorized Returned 

Goods Receipt number will not be accepted. 

All returned goods 

are subject to a restocking charge. Written permission must 

be  obtained  through  a  local  Riello  distributor  and  must 

be  obtained  by  your  qualified  service  technician.  Contact 

your installing/service contractor to initiate a claim. Do not 

contact Riello S.p.A. or Evergreen Products International Inc. 

as they cannot provide technical assistance unless you are a 

qualified service technician. 

 

− When ordering parts, you must specify the model and serial 

number of the boiler. Parts can only be purchased through 

an authorized Riello distributor by your installation/service 

technician.

 

When ordering under warranty conditions, your installation/

service technician must also specify the date of installation. 

 

− Purchased parts are subject to replacement only under the 

manufacturer’s warranty. Debits for defective replacement 

parts will not be accepted and will be replaced in kind only 

per 

R

 standard warrant.

4  INTRODUCTION

The 

Residence PRO

 boilers have a new ACC (Active Combustion 

Control) system.

This new control system ensures functionality, efficiency and low 

emissions under any conditions. 

The  ACC  system  uses  an  ionization  sensor  (flame  sensor)

immersed in the burner flame, whose information allows the 

control board to operate the gas valve that regulates the fuel.

This sophisticated control system provides the auto-regulation 

of the combustion, so there is no need for an initial calibration; 

however, it is recommended (required in some jurisdictions) that 

a combustion analysis is performed during initial start-up and 

annual maintenance by a qualified installer or service agency.

The ACC system is able to adapt the boiler to operate with different 

gas compositions, different air inlet and exhaust vent lengths 

and different altitudes (within the specified design limits).

The ACC system can also perform an auto-diagnostic operation 

that locks out the burner before the permitted upper emission 

limit is exceeded.

Residence PRO

  is  a  direct  vent,  Category  IV,  wall  hung  fan 

assisted  room-sealed  condensing  boiler  f

or heating and 

production of domestic hot water

.

This  appliance  is  designed  for  use  with  a  sealed  system  only; 

consequently it is not intended for use on power vented system.

This manual is an integral part of the appliance. It is therefore necessary 

to ensure that the manual is handed to the person responsible for the 

property in which the appliance is located/installed. A replacement 

copy can be obtained from www.egproductsolutions.com

.

IMPORTANT

It is the law that all gas appliances are installed by a competent 

person.

It is in your own interest and that of safety to ensure that the law 

is complied with

.

 

− The  installation  must  conform  to  the  requirements  of  the 

authority  having  jurisdiction  or,  in  the  absence  of  such 

requirements, to the National Fuel Gas Code, ANSI Z223.1/NFPA 

54. Where  required  by  the  authority  having  jurisdiction,  the 

installation  must  conform  to  the  Standard  for  Controls  and 

Safety Devices for Automatically Fired Boilers, ANSI/ASME CSD-1.

 

− The installation should conform with CAN/CSA B149.1 INSTALLATION 

CODE and/or local installation Code, plumbing or waste water 

codes and other codes as applicable

.

 

− Clearances from combustible material must be strictly adhered to.

 

− Manufacturers instructions must NOT be interpreted in anyway 

as overriding local regulations.

Содержание Residence PRO 32 KIS

Страница 1: ...o do so may result in an explosion or fire WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your...

Страница 2: ...TIONSHIPS 10 4 13 ACCESS TO THE INFO MENU 10 4 14 LIGHTS AND FAULTS RESET PROCEDURE 10 5 HOW TO 12 5 1 HOW TO INCREASE THE SYSTEM PRESSURE 12 5 2 HOW TO SHUT DOWN THE SYSTEM FOR SHORT PERIODS 12 5 3 H...

Страница 3: ...an of the boiler WARNING There is a risk of pipes freezing if the building is left unattendedforlongperiodsoftime inexcessof12hrs infreezing temperatures In the event the building will be unoccupied f...

Страница 4: ...ivez les instructions intitul es Comment couper l admission de gaz de l appareil et appelez un technicien qualifi ou le fourmisseur de gaz pour ouvrir pour fermer 1 R glez le thermostat la temp rature...

Страница 5: ...ed in the burner flame whose information allows the control board to operate the gas valve that regulates the fuel This sophisticated control system provides the auto regulation of the combustion so t...

Страница 6: ...3 Flame sensor 14 Manual air vent hose 15 Manual upper air vent valve 16 Flue temperature sensor 17 Positive air pressure tube 18 Flue outlet 19 Air intake 20 Negative air pressure tube 21 Air pressur...

Страница 7: ...ssure is low and needs to be re pressureized Icons RESET MENU 136 F OK MODE Display SOME OF THE ICONS SHOWN ON THE CONTROL DEVICE SCREEN AT THE START UP PHASE MIGHT NOT BE AVAILABLE DURING FUNCTIONNIN...

Страница 8: ...nician or gas supplier After completing all operations required to prepare commissioning proceed as with the instructions in sections 4 6 and 4 7 sequentially to complete lighting the boiler 4 6 PROGR...

Страница 9: ...onds the value will be confirmed automatically 9 9CAUTION Adjusting your maximum heating setpoint past the design temperature of your heat emitters may cause minor injuries or property damage Consult...

Страница 10: ...mostat is set too high 4 13 ACCESS TO THE INFO MENU 9 9NOTICE Make sure you are in the Operation mode backlight ON see section 10 6 Using the boiler control panel it is possible to access the INFO men...

Страница 11: ...st purging for 45 seconds at the fan s maximum speed It is not possible to release the error before the end of the post purging unless the boiler s power supply is switched off E022 iono alarm E023 io...

Страница 12: ...maintained until the outlet water temperature reaches 131 F 55 C 9 9NOTICE The activation of the ANTI FREEZE function is indicated by the icon displayed on the front control circulator anti seize the...

Страница 13: ...technician This appliance produces carbon monoxide CO gases The venting should never be taken apart by anyone other than a qualified technician The venting should not be separated Failure to comply m...

Страница 14: ...he boiler and purge all air from system 19 p Power boiler back on 20 p Verify the polarity and ground of the power supply L N 120v L G 0v N G 0v 21 p Check incoming power to spark generator 120 vac 22...

Страница 15: ...terior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign sh...

Страница 16: ...ce accident corrosive atmospheres physical damage to the boiler alterations by unauthorized service operation contrary to the Manufactures instructions including annual cleaning or if the serial numbe...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ......

Страница 20: ...387 4663 Email info egproductsolutions com Professional Resources egproductsolutions com The Company is constantly working to perfect all of its production processes therefore the aesthetics and size...

Отзывы: