19
2903430
GB
Electrical system
7.2
Electrical wiring
Key to lay-out (Fig. 18)
C
Capacitor
E
Ignition electrodes
F
Flame detector
MV
Motor
P
Short circuit socket
RS
Remote reset
SB
External signal lock-out (230V - 0.5A max)
TB
Burner-earth
TL
Thermostat of heat demand
TS
Safety thermostat
V
Oil valve
XP6
6 pole socket
X6
6 pin plug
CONTROL BOX
G
re
e
n
/Y
e
llo
w
G
re
y
R
e
d
B
la
c
k
Blue
Black
White
D12059
Fig. 18
TO BE DONE BY
THE INSTALLER
CARRIED OUT
IN THE FACTORY
~ 50Hz - 230V
Main switch
White
WARNING
➤
Do not invert the neutral with the phase in the
electrical supply line.
➤
Check that the electrical supply of the burner
corresponds to that shown on the identifica-
tion label and in this manual.
➤
The section of the conductors must be at
least 1mm
2
. (Unless otherwise required by
local guidelines and laws).
WARNING
Test the burner by checking the shutdown of the
burner by opening the thermostats and the lockout
by darkening the photoresistance.
CAUTION
➤
If the hood is still present, remove it and pro-
ceed with the electrical wiring according to
the wiring diagrams.
➤
Use flexible cables in compliance with the EN
60 335-1 standard.
Содержание RDB1 12/18 WH