Riello Multipass 10A Скачать руководство пользователя страница 2

13 

ENGLISH 

 

USER MANUAL 

 
 
 

1

 

INTRODUCTION AND SAFETY 

14

 

1.1

 

I

NTRODUCTION

 14

 

1.2

 

P

RECAUTIONS AND SAFETY RULES

 14

 

2

 

PRESENTATION 15

 

2.1

 

O

PERATING MODES

 16

 

3

 

INSTALLATION 17

 

3.1

 

R

ACK VERSION

 17

 

3.2

 

W

ALL VERSION 

(BOX) 18

 

3.3

 

I

NSTALLATION INSTRUCTIONS

 19

 

3.4

 

C

ONNECTING THE 

BYPASS 20

 

4

 

USING THE BYPASS 

21

 

4.1

 

I

NSTRUCTIONS TO BE FOLLOWED FOR 

UPS

 MAINTENANCE

 21

 

4.2

 

BYPASS

 LIMITATIONS OF USE

 21

 

5

 

TECHNICAL SPECIFICATIONS 

22

 

 
 

Содержание Multipass 10A

Страница 1: ...MANUAL BYPASS Manuale D uso User s Manual...

Страница 2: ...4 2 PRESENTATION 15 2 1 OPERATING MODES 16 3 INSTALLATION 17 3 1 RACK VERSION 17 3 2 WALL VERSION BOX 18 3 3 INSTALLATION INSTRUCTIONS 19 3 4 CONNECTING THE BYPASS 20 4 USING THE BYPASS 21 4 1 INSTRUC...

Страница 3: ...he plug from the power supply as this would disconnect the safety earth for all devices powered b The BYPASS has HAZARDOUS electrical voltages inside it Any maintenance must ONLY be performed by train...

Страница 4: ...PS The BYPASS makes it possible to switch the utilities connected to it onto the main power line in the event that the UPS is switched off or becomes blocked The BYPASS is supplied for installation in...

Страница 5: ...rating mode BYPASS UPS UPS MAINS BYPASS UPS MAINS UPS RACK BOX 10A 16A SWITCH SWITCH UPS BYPASS SWITCH SWITCH to select the load power supply from the UPS or mains BYPASS position MAINS light green on...

Страница 6: ...he neutral N and phase P indications relating to plugs and outlets the BYPASS inserted in a system does not change the existing neutral system The neutral system will still be modified if an isolation...

Страница 7: ...X Attach the Bypass to the wall bracket as shown in the figure below position the slotted L bracket without fully tightening the two screws The figure below shows the drilling template for installing...

Страница 8: ...lation instructions Before connecting the BYPASS to the UPS ensure the following conditions are met 1 Do not position in areas exposed to direct sunlight or hot air 2 Keep the ambient temperature betw...

Страница 9: ...t configurations vary depending on the versions 1 Check that the SWITCH is in the BYPASS position 2 Connect the load to the output outlets Load N B The plug outlet configurations vary depending on the...

Страница 10: ...when it is necessary to repair replace or carry out maintenance on the UPS a Move the SWITCH to the BYPASS position b Turn off the UPS c Disconnect the UPS d Reconnect the UPS new or repaired e Turn...

Страница 11: ...Rated voltage Vac 220 230 240 Switching time ms typical 3 maximum 5 Maximum current A 16 Ambient temperature C 0 40 Humidity 90 without condensation Protective devices overcurrent short circuit Dimens...

Страница 12: ......

Страница 13: ...0MNBYM10A2LUA...

Отзывы: