USER
7
START-UP
Have
r
’s Technical Assistance Service start-up your boiler for the first time. Once this has been done, the boiler
can be left to function automatically. Under certain circumstances, such as after long periods of disuse, the user may
need to re-start it without involving the Technical Assistance Service. Before doing so, perform the following checks and
operations:
- Check that the fuel cock and heating system water
cock are shut.
- While the system is still cold, check that the pressure
in the heating circuit is
over 1 bar
but below the maxi-
mum limit specified for the boiler. If water pressure is
low, contact
r
’s Technical Assistance Service.
- Set the room thermostat to the required temperature
(~20°C) or, if the system has a timer or temperature
controller, make sure that this is switched “On” and
adjusted to the required temperature (~20°C).
- Turn the system’s mains power switch ON.
- Turn the boiler thermostat to about the middle of the
section with three lines.
On models 26 BK and 35 BK:
- Turn the boiler thermostat to about the middle of the
section with two lines.
20
40
60
80
100
0
120
20
40
60
80
100
0
120
20
40 60 80
100
4
3 2 1
0
0
120