background image

4

GENERAL INFORMATION

 

GENERAL INFORMATION

1.1 

General Safety Information

 

9

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to the 

highest standards in compliance with the instructions pro-

vided by 

R

 in this instruction manual, and that it con-

forms to all applicable laws and standards.

 

9

This product must only be used for the purpose for which it 

is designed and made, as specified by 

R

R

 declines 

all responsibility, contractual or other, for damage to prop-

erty or injury to persons or animals caused by improper in-

stallation, adjustment, maintenance or use.

 

9

The room where the boiler is installed must be proper-

ly ventilated to ensure a sufficient supply of air for correct 

combustion.

 

9

If you notice any water leaks, disconnect the boiler from the 

mains electricity supply and shut off the water supply.

 

9

The boiler must be serviced at least once a year.

 

9

Periodically check that pressure in the central heating cir-

cuit, when cold, is approximately 1.5 bar and below the 

maximum limit specified for the boiler. If necessary, top up 

through the filling cock or contact the 

R

 Technical Assis-

tance Service or a qualified heating engineer.

 

9

If the boiler is not going to be used for an extended peri-

od of time, perform the operations described later in this 

manual.

 

9

This manual is an integral part of the equipment and there-

fore must be stored carefully and must ALWAYS accompany 

the boiler even if it is sold to another Owner or User or trans-

ferred to another plant. If it is damaged or lost, request an-

other copy from your local Technical Assistance Service 

R

.

1.2 

Precautions

The operation of any appliance that uses fuel, electrical power 

and water demands that a number of fundamental safety pre-

cautions be respected:

 

0

Do not allow children or infirm persons to operate the sys-

tem unsupervised.

 

0

It is forbidden to use electrical devices or equipment, such 

as switches, appliances, etc. if there is a smell of gas or un-

burnt products. If so:

 

− Ventilate the room, opening doors and windows

 

− Close the fuel shut-off cock.

 

0

Do not touch the boiler while barefoot or wet.

 

0

Never clean or service the boiler without first disconnect-

ing it from the mains electricity supply by turning the mains 

power switch and the control panel switch OFF.

 

0

Never pull, disconnect, or twist the electrical cables coming 

from the appliance even if it is disconnected from the mains 

electricity supply.

 

0

Do not obstruct or restrict the vents in the room where the 

boiler is installed. Adequate ventilation is essential for cor-

rect combustion.

 

0

Do not expose the boiler to the elements. It is not designed 

for use outdoors.

 

0

It is prohibited to leave inflammable substances and con-

tainers in the room where the boiler is installed.

 

0

Do not dispose of packaging material into the environment, 

or leave it within the reach of children, since it can become 

a potential hazard. Dispose of packaging material in com-

pliance with applicable legislation.

 

0

It is forbidden to operate the boiler without water.

Содержание GITRE

Страница 1: ...cod 20112452 rev 0 02 2016 GITRÈ GITRÈ B 100 GITRÈ EN USER MANUAL ...

Страница 2: ...ouble free installation and efficient functioning of your GITRÈ boiler Please accept our renewed thanks for your purchase Riello S p A CONFORMITY GITRÈ boilers conform to the following directives Directive 92 42 EEC on efficiency requirements Electromagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Ecodesign Directive 2009 125 CE for energy related prod ucts Energy Labe...

Страница 3: ...l Safety Information 4 1 2 Precautions 4 1 3 Description of the appliance 5 1 4 Safety devices 5 1 5 System layout 5 1 6 Control panel 7 2 USE 9 2 1 Putting into service 9 2 1 1 Preliminary operations 9 2 1 2 Start up 9 2 1 3 Ignition failure 10 2 1 4 Resetting the burner and safety thermostat 10 2 2 Temporary shutdown 11 2 3 Preparing for extended periods of disuse 12 2 4 Cleaning and servicing t...

Страница 4: ... of the equipment and there fore must be stored carefully and must ALWAYS accompany the boiler even if it is sold to another Owner or User or trans ferred to another plant If it is damaged or lost request an other copy from your local Technical Assistance Service R 1 2 Precautions The operation of any appliance that uses fuel electrical power and water demands that a number of fundamental safety p...

Страница 5: ...ge cylinder DHW heat requests are prioritised over central heating requests 1 4 Safety devices GITRÈ boilers incorporate the following safety and control de vices A manual reset safety thermostat that forces a safe ty shutdown if boiler temperature exceeds the safety threshold 110 C The sensor used to monitor this tem perature is located on the body of the heat exchanger A minimum temperature ther...

Страница 6: ...3 CH circuit drain cock 4 Automatic vent valve 5 Storage cylinder 6 Casing 7 Non return valve 8 Boiler circulator 9 Boiler temperature sensor socket 10 Lifting holes 11 Burner 12 Boiler body 13 Flue gas exhaust fitting 14 Domestic cold water inlet 15 DHW circulation 16 Storage cylinder temperature sensor socket 17 DHW outlet 18 Magnesium anode ...

Страница 7: ... to set the temperature of the central heating water setting range 55 82 C 55 82 4 Electrical power indicator green Lights to show that the boiler is receiving electrical power 5 Burner lockout indicator red Lights to show that the burner locked out 6 Manual reset for safety thermostat Allows you to reset the boiler if the safety thermostat trips Unscrew the protective cover to access the reset bu...

Страница 8: ...s to show that the boiler is receiving electrical power 5 Burner lockout indicator red Lights to show that the burner locked out 6 Summer I Winter II selector 7 Storage cylinder temperature gauge Displays the temperature of the domestic hot water in the storage cylinder 8 Manual reset for safety thermostat Allows you to reset the boiler if the safety thermostat trips Unscrew the protective cover t...

Страница 9: ...ll the checks listed above proceed as follows to start up the boiler for the first time ONLY FOR MODELS GITRÈ 4 GITRÈ 5 GITRÈ 6 Turn the boiler s mains power switch ON Set the room thermostat to the required temperature 20 C or if the system has a timer or timer thermostat make sure that this is switched ON and adjusted to the required temperature 20 C Open the control panel access door ONLY FOR M...

Страница 10: ...tion errors or malfunctions occur the burner enters LOCKOUT This is shown by the red button light on the burner and by the warning light on the control panel 20 40 60 80 100 0 120 9 9If a LOCKOUT SHUTDOWN occurs wait about 30 seconds be fore resetting the burner 2 1 4 Resetting the burner and safety thermostat To restore normal startup conditions open the protective cover over the control panel an...

Страница 11: ... ZERO Open the control panel access door Turn the control panel power switch to 0 OFF and make sure that the green power indicator goes out 20 40 60 80 100 0 120 switch the boiler OFF at the mains power switch 9 9Do NOT perform this procedure if outdoor temperature might fall below ZERO risk of freezing Then proceed as follows Adjust the boiler thermostat to its minimum setting 20 40 60 80 100 0 1...

Страница 12: ...nce Service is qualified to satisfy these legal requirements and can also provide useful information on MAINTENANCE PROGRAMMES designed to guarantee greater safety compliance with applicable legislation freedom from the risk of fines in the event of spot checks Regular maintenance is essential for the safety efficiency and durability of the boiler Servicing is a legal requirement and must be perfo...

Страница 13: ...nical Assistance Service The generator is at temperature but the heating system is cold Air in the circuit Contact your local Technical Assistance Service Pump malfunctioning Contact your local Technical Assistance Service Minimum temperature thermostat faulty Contact your local Technical Assistance Service There is a smell of fumes Fumes escaping into the air Contact your local Technical Assistan...

Страница 14: ...nce Service Storage cylinder temperature sensor problem Contact your local Technical Assistance Service Insufficient domestic hot water Incorrect pressure in DHW circuit Contact your local Technical Assistance Service Lime scale or deposits in storage cylinder Contact your local Technical Assistance Service Storage cylinder thermostat Check the setting of the storage cylinder thermostat 3 RECYCLIN...

Страница 15: ...15 RECYCLING AND DISPOSAL ...

Страница 16: ...Tel 0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice ...

Отзывы: