background image

39 

 

I

NTRODUCTION

 

Thank you for choosing our Uninterruptible Power Supply (UPS). 

Our company is highly specialised in the development and production of uninterruptible power supplies (UPS). 
The UPS in this range are high quality products, designed and built with care to ensure optimum performance. 
This equipment can be installed by anyone, subject to a 

CAREFUL AND THOROUGH READING OF THIS 

MANUAL. 

This manual contains detailed instructions on how to use and install the UPS.  

For information on using and getting the best performance from your UPS, this manual should be kept 
safely near the UPS and CONSULTED BEFORE TAKING ANY ACTION.

 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
© Reproduction of any part of this manual, partial or in full is strictly prohibited without the manufacturer’s prior consent. The 
manufacturer reserves the right to modify the product described herein, in order to improve it, at any time and without notice. 
Microsoft, Windows, and the Windows logo are trademarks or registered trademarks of Microsoft Corporation in the United 
States and/or other countries.

 

Содержание DVD 150

Страница 1: ...1...

Страница 2: ...36 GB USER MANUAL GB...

Страница 3: ...LLATION OF THE DVD MODELS WITH BATTERY BOX 48 POSITIONING THE FRONT PANEL LCD FOR DVD MODELS 49 INSTALLING DVR AND DVD MODELS IN A RACK CABINET 51 CONNECTION 52 CONNECTION TO THE NET TEL PROTECTION DE...

Страница 4: ...RT 62 COMMUNICATION SOCKET 62 SOFTWARE 63 MONITORING AND CONTROL SOFTWARE 63 CONFIGURATION SOFTWARE 63 ALARMS AND INDICATORS 64 REPLACING THE BATTERY 65 DIALOG VISION TOWER 65 DIALOG VISION RACK 66 DI...

Страница 5: ...tailed instructions on how to use and install the UPS For information on using and getting the best performance from your UPS this manual should be kept safely near the UPS and CONSULTED BEFORE TAKING...

Страница 6: ...able CHARACTERISTICS Sinusoidal output voltage Front panel LCD Microprocessor control for high reliability High frequency technology Automatic correction of input voltage fluctuations by the built in...

Страница 7: ...minal power VA 500 800 1100 1500 2000 500 800 1100 1500 2200 3000 Nominal power W 350 540 740 1050 1350 350 540 740 1050 1540 2100 Nominal output voltage Vac 200 208 220 230 240 Dimensions LxHxD mm 11...

Страница 8: ...42 PRESENTATION REAR VIEW DVT 50 80 110 DVT 150 200 DVR 50 80 110 DVD 150...

Страница 9: ...Cooling fan 3 Net Tel protection 4 Input thermal protection 5 IEC network input plug 6 IEC output plug max 10A 7 Expansion slots for interface cards 8 Battery expansion connector 9 IEC output plug max...

Страница 10: ...kaging should contain the following UPS IEC 10A power cable IEC 16A for DVD models 220 300 only 2 IEC 10 A connection cables USB cable Plastic supports DVD model only Guides for rack installation hand...

Страница 11: ...CHECKING THE CONTENTS After opening the packaging check the contents The packaging should contain the following Battery Box UPS Battery Box connection cable Guides for rack installation handles kit U...

Страница 12: ...nsation Warning A long period of use in an environment with a temperature over 25 C will shorten battery life The UPS should be placed at least 20 cm away from a monitor in order to avoid interference...

Страница 13: ...DELS WITH BATTERY BOX 1 Assemble the supports and the extension as shown in the figure 2 Put the UPS and the battery box in a vertical position and place the two supports close to them 3 Carefully ins...

Страница 14: ...r tower The information below explains how to rotate the display A From Rack to Tower 1 Place the UPS flat and press the key shown 2 Rotate the LCD display 90 3 Reinsert the display in its housing B F...

Страница 15: ...n be installed in a 19 rack cabinet The installation procedure is described below 1 Align and screw the handles onto the sides of the UPS 2 Secure the guides onto the rack cabinet supports with the sc...

Страница 16: ...one modem network card etc is inserted in the connector marked OUT N B This protection device limits the effects of an overvoltage but does not guarantee absolute protection POWERSHARE All the models...

Страница 17: ...MS Imax 20mA between Pin 1 and 2 of the terminal using an unshielded wire of diameter 18 22 AWG 0 75 mm2 0 3mm2 5 Reconnect the terminal to the EPO input 6 Ensure that the switch connected to the EPO...

Страница 18: ...current automatically increases to 6 A START UP SHUTDOWN To start up and shut down the UPS press the ON and OFF switch for at least three seconds Starting up for the first time after about 30 seconds...

Страница 19: ...53 SYSTEM DESCRIPTION FRONT PANEL The front panel consists of a display and ON OFF and SELECT keys LCD SELECT button LCD Front panel ON button OFF button Part A Part B Part D Part C...

Страница 20: ...voltage unit Volt BATTERY estimated back up time as a percentage of the battery charge BATTERY MIN estimated battery back up time unit Minutes Note The estimated back up time in minutes is also provid...

Страница 21: ...at regular 4 second intervals Flashing When operating in battery mode the UPS signals that it is about to switch off due to end of discharge In this state it beeps at regular 1 second intervals Steady...

Страница 22: ...d intervals Once the load has been reduced to within the 100 threshold the UPS will return to normal operating mode Warning If the overload is too high the protection device will be activated and the...

Страница 23: ...ller UPS internal error Contact the reseller SETTING THE VALUES ON THE FRONT PANEL LCD The LCD has two parts left Part A and right Part B The left side displays the following parameters Input voltage...

Страница 24: ...play Part A and Capacity as a percentage of the battery on the right side Part B Configuration example Press SELECT for 3 seconds Press SELECT to change the field Press ON to confirm the field Press S...

Страница 25: ...t Intermittent 1s on 1s off t 1 2 3 4 5 6 0 1 7 8 9 10 g The UPS is performing the battery test Intermittent for 3 times 0 5s on 0 5s off t 1 2 3 4 5 6 0 1 7 8 9 10 h If none of the events in the prev...

Страница 26: ...PS Failure Alarm contact closed in the event of failure or signalling of alarms by the UPS maximum values 25mA 35Vdc Vce sat max 1 5V 25mA e Input programmable via RS232 5 15 Vdc USB PORT The USB port...

Страница 27: ...cable provided Insert the CD Rom and select the operating system required Follow the installation instructions For more detailed information on installing and using the software refer to the software...

Страница 28: ...tact the reseller There may be no output voltage in the socket used Check the output fuse if present The UPS is not powering the loads There is no output voltage on the sockets 1 Check the connection...

Страница 29: ...s of leakage contact the reseller immediately Recycle the used batteries Never throw batteries into a fire as they may explode Do not open or damage the batteries The electrolyte contents are harmful...

Страница 30: ...ands 2 Disconnect the UPS battery cable 3 Undo the screws securing the support to the UPS and remove the plate securing the batteries 4 Remove the batteries on a flat surface 5 Insert the new batterie...

Страница 31: ...both hands 2 Undo the screws securing the support to the UPS and remove the plate securing the batteries 3 Disconnect the cable 4 Remove the batteries on a flat surface 5 Insert the new batteries in t...

Страница 32: ...cycles 110 alarm and failure after 30 seconds OVERLOAD From battery power 120 failure after 5 cycles TRANSFER TIME Typical 4 msec 6 msec max Nominal battery voltage 12V 24V 24V 48V 48V BATTERY Recharg...

Страница 33: ...cles TRANSFER TIME Typical 4 msec typical 6 msec max Nominal battery voltage 12V 18V 24V 48V 96V 96V BATTERY Recharge time Less than 6 hours at 90 Dimensions LxHxD mm 438X44 3X460 19 x1Ux460 438X87 9X...

Страница 34: ...165...

Отзывы: