27
ENGLIS
H
The
BAG
3
MIX FAMILY COND
can be wall-mounted or “built-
in”, and can be located near the boiler or at a distance,
provided the length of the plumbing and electrical con-
nections between the boiler and the BAG
3
MIX FAMILY COND
unit do not exceed 15 metres.
The BAG
3
MIX FAMILY COND can be installed in positions ex-
posed to the weather (rain, sun, ice, etc.) only if in “built-
in” installation.
Note:
The wiring supplied is 2 metres long.
9
In the case of installation of BAG
3
MIX FAMILY COND with built
in boilerss and electric connection on the lower side of the
unit, it is necessary that the wrinkled pipe comes out of ap-
prox 10 cm.
Wall-mounted installation
When the BAG
3
MIX FAMILY COND is wall-mounted it must be
supported by two expanding wall anchors (supplied) that
are suitable for the type of wall and weight of the equip-
ment.
We recommend using pipe sleeves built into the wall in
order to limit the infiltration of water.
These pipe sleeves are not supplied with the unit.
Electrical protection level IP10D.
“Built-in” installation
When the BAG
3
MIX FAMILY COND unit is built-in:
- Provide the building work, complete with a niche of suit-
able size for the BAG
3
MIX FAMILY COND, to suit the thickness
of the wall (minimum indicative dimensions shown in
the figure).
- Position the BAG
3
MIX FAMILY COND in position, and re-
member to open out the two support lugs to fix it more
securely.
- Protect the side edges and front while building in the
device.
Since the plumbing and electrical connections between
the system and the BAG
3
MIX FAMILY COND must be contained
within the overall size of the device itself, first position
the BAG
3
MIX FAMILY COND and then the entry and exit pipes
for the system and the conduiting for the electric cables.
Electrical protection level IPX4D.
lug
2.3
Installation of the appliance