27
ENd USER
When an error
n
occurs, press the key (6) to display
the error message. The message on the display descri-
bes the cause of the error.
If an error occurs, an alarm may also activate a suitably
configured Qx... relay.
This parameter resets the alarm relay.
N°
Description
6710
Alarm relay reset
The difference between the setpoint and the current
temperature is monitored. If this difference persists for
longer than the time set here, the system generates an
error .
N°
Description
6740
CH flow 1 temperature alarm
6741
CH flow 2 temperature alarm
6743
Boiler temperature alarm
The controller memorises the codes and dates for the
last 10 errors.
N°
Description
History . . .
ERROR TABLE
Error code
Description
0
No error
10
Outside sensor
20
Boiler temperature sensor 1
25
Solid fuel boiler temperature sensor (not used)
26
Flow manifold temperature sensor
28
Flue gas temperature sensor
30
CH flow 1 sensor
32
CH flow 2 sensor
38
Primary controller flow temperature sensor
40
CH return temperature sensor 1
50
DHW 1 temperature sensor (*)
52
DHW 2 temperature sensor (*)
57
DHW circulation pump temperature sensor (*)
60
Room temperature sensor 1
65
Room temperature sensor 2
68
Room temperature sensor P
70
Storage cylinder temperature sensor 1
71
Storage cylinder temperature sensor 2
73
Solar collector temperature sensor 1
81
LPB short circuit
82
LPB address conflict
83
BSB short circuit
84
BSB address conflict
(*) Only with a remote storage cylinder
ROOM UNIT: CONTROL OF SOLAR SYSTEM AND ANY ADDITIONAL SYSTEMS INSTALLED AS ACCESSORIES
Error
30: Flow sensor 1
Attention
3: Maintenance interval exceeded
6
6