background image

GENERAL

6

7200 Kombisolar 3S

 triple coil combination storage 

cylinders come in the form of an inertial (buffer) storage 
cylinder with three internal coils. The bottom coil receives 
heat from the solar circuit while the top coil receives heat 
from the boiler. A third coil in stainless steel produces 
domestic hot water.

The most important technical features of these combina-
tion storage cylinders are:
-  The cylinder and coils are specially designed and sha-

ped for optimum performance in terms of stratification, 
heat exchange and replenishment times.

-  The stainless steel, rapid heat exchange coil for dome-

stic hot water production is bacteriologically inert and 
guarantees maximum hygiene and reduced lime scale 
deposits.

- Water fittings are available at different heights, permit-

ting different boilers to be used without reducing the 
stratification effect.

-  CFC-free polyurethane insulation and an elegant exter-

nal casing reduce heat loss and improve efficiency.

- Excellent flexibility permits use in both high and low 

temperature systems.

-  Dimensions are extremely compact thanks to the clever 

combination of an inertial storage cylinder and dome-
stic hot water coil.

7200 Kombisolar 3S

 triple coil combination storage 

cylinders can be connected to a special solar controller 
and can be integrated in solar heating systems in which 

r

 boilers or water heaters serve as auxiliary heat 

generators.

r

 

7200 Kombisolar 3S 

combination storage cylinders are identified by three plates:

If these plates or any other means of clearly identifying 
the product are defaced, removed or lost, proper 
installation and servicing may be rendered difficult.

– Data plate

  This lists the technical specifications and 

performance of the product.

– Product identification plate

  This states the name of the product.

– Serial number plate

  This specifies the serial number, model, 

consumption and capacity.

bar

V-Hz

l

W

bar

°C

kW

l

°C

kW

RIELLO S.p.A.

Via Ing.Pilade Riello 7

37045 Legnago (VR) - ITALY

RIELLO S.p.A.

Via Ing.Pilade Riello 7

37045 Legnago (VR) - ITALY

T067730ED

COMBINATION STORAGE CYLINDER  -  KOMBISPEICHER

Model

Modell

Code

Bestellnummer

Serial number

Seriennummer

Year of manufacture

Baujahr

DHW coil capacity

Inhalt der Warmwasserwendel

Power absorbed by top coil [Primary T = 80°C]

Leistungsaufnahme obere Rohrwendel [T Primärkreis 80°C]

Inertial storage cylinder capacity

Inhalt des Pufferspeichers

Maximum working pressure (DHW)

Max. Druck Warmwasserbetrieb

Maximum working temperature (DHW)

Max. Temp. Warmwasserbetrieb

Electrical consumption

Stromaufnahme

Maximum working pressure of inertial storage cylinder

Max. Druck Pufferspeicher-Betrieb
Maximum working temperature of inertial storage cylinder

Max. Temp. Pufferspeicher-Betrieb

Power supply

Stromversorgung

Obligatory ground connection  -  Erdschluss ist Vorschrift

l/h

l/h

Serial number

Seriennummer

Power absorbed by top coil

Leist.aufn. o. Wendel

Model

Modell

DHW prod., cont. draw

WW-Bereitung durchg. Anzapfung

DHW production, continuous draw

Warmwasserbereitung bei durchgehender Anzapfung 

 [ 

 T 35°C]

 [ 

 T 35°C]

bar

V-Hz

l

W

bar

°C

kW

l

°C

kW

RIELLO S.p.A.

Via Ing.Pilade Riello 7

37045 Legnago (VR) - ITALY

RIELLO S.p.A.

Via Ing.Pilade Riello 7

37045 Legnago (VR) - ITALY

T067730ED

COMBINATION STORAGE CYLINDER  -  KOMBISPEICHER

Model

Modell

Code

Bestellnummer

Serial number

Seriennummer

Year of manufacture

Baujahr

DHW coil capacity

Inhalt der Warmwasserwendel

Power absorbed by top coil [Primary T = 80°C]

Leistungsaufnahme obere Rohrwendel [T Primärkreis 80°C]

Inertial storage cylinder capacity

Inhalt des Pufferspeichers

Maximum working pressure (DHW)

Max. Druck Warmwasserbetrieb

Maximum working temperature (DHW)

Max. Temp. Warmwasserbetrieb

Electrical consumption

Stromaufnahme

Maximum working pressure of inertial storage cylinder

Max. Druck Pufferspeicher-Betrieb
Maximum working temperature of inertial storage cylinder

Max. Temp. Pufferspeicher-Betrieb

Power supply

Stromversorgung

Obligatory ground connection  -  Erdschluss ist Vorschrift

l/h

l/h

Serial number

Seriennummer

Power absorbed by top coil

Leist.aufn. o. Wendel

Model

Modell

DHW prod., cont. draw

WW-Bereitung durchg. Anzapfung

DHW production, continuous draw

Warmwasserbereitung bei durchgehender Anzapfung 

 [ 

 T 35°C]

 [ 

 T 35°C]

Identification

IDENTIFICATION

Product description

PRODUCT DESCRIPTION

Содержание 7200 KOMBISOLAR 1000 3S

Страница 1: ...cod 20015096 rev 11 09 17 7200 Kombisolar 3S EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Страница 2: ...2 MODEL CODE 7200 KOMBISOLAR 430 3S 20010131 7200 KOMBISOLAR 550 3S 20010138 7200 KOMBISOLAR 750 3S 20010139 7200 KOMBISOLAR 1000 3S 20010140 RANGE...

Страница 3: ...tructions and precautions that must be observed to ensure the trouble free installation and efficient functioning of your r 7200 Kombisolar 3S com bination storage cylinder Please accept our renewed t...

Страница 4: ...description 6 Identification 6 Design 7 Technical specifications 8 Accessories 12 Water circuit 13 INSTALLATION 14 Unpacking the product 14 Dimensions and weight 14 Handling 15 Place of installation 1...

Страница 5: ...erfere with any control devices without specific authorisation and instructions from the manufacturer The operation of any appliance that uses electrical power and water demands that a number of funda...

Страница 6: ...67730ED COMBINATION STORAGE CYLINDER KOMBISPEICHER Model Modell Code Bestellnummer Serial number Seriennummer Year of manufacture Baujahr DHW coil capacity Inhalt der Warmwasserwendel Power absorbed b...

Страница 7: ...ket 8 Top coil 9 Storage cylinder temperature gauge 10 Domestic hot water outlet 11 DHW coil 12 Vent valve fitting 13 Inlet from boiler 14 Inlet from 2nd boiler 15 Central heating outlet 16 Return to...

Страница 8: ...ture gauge sensor socket diameter 1 2 M Top primary coil water capacity 7 1 8 0 10 0 10 0 l Bottom primary coil water capacity 11 0 12 8 17 4 19 8 l DHW coil water capacity 23 6 23 6 30 4 30 4 l Top p...

Страница 9: ...erature 80 C Performance achieved with boiler of suitable power configured for a flow rate of 1500 l h Description 7200 Kombisolar 3S 430 550 750 1000 Domestic hot water production 2300 2400 2600 2650...

Страница 10: ...mperature 80 C Performance achieved with boiler of suitable power configured for a flow rate of 3000 l h Description 7200 Kombisolar 3S 430 550 750 1000 Domestic hot water production 610 640 750 750 l...

Страница 11: ...op 7200 Kombisolar 3S BOTTOM COIL PRESSURE DROP mbar FLOW RATE l h 600 700 800 900 500 400 300 200 100 0 0 1000 2000 3000 4000 5000 6000 430 550 750 1000 PRESSURE DROP mbar FLOW RATE l h 600 700 800 9...

Страница 12: ...ntroller 4383382 RIELLO Solar MR water outlet and return kit 4383386 RIELLO Solar MR 25 70 water outlet and return kit 20011545 1 curved union kit for storage cylinder connection 4383171 Single phase...

Страница 13: ...recommended solar heating circuit flow rate see the installation instructions for the water outlet and return kit UAC Domestic hot water outlet EAF Domestic cold water inlet RE Sleeve for electric hea...

Страница 14: ...ckage consisting of a triple wall cardboard box 7200 Kombisolar 3S 430 550 or a plastic bag 7200 Kombisolar 3S 750 1000 on a wooden pallet The following items are delivered in a plastic bag inside the...

Страница 15: ...s able to support the weight of the storage cylinder Carefully rotate and slide the storage cylinder off the pallet on to the platform Make sure that the storage cylinder is perfectly stable and then...

Страница 16: ...on shells 6 Reverse the above steps to fit the insulation again b Make sure that the insulation shells 7 are securely fixed in place by straps before fitting the plastic cover Use a strap wrench if ne...

Страница 17: ...ndards Make sure that the circuit has been flushed out to remo ve all sludge and lime scale and has been vented and seal tested Make sure that a suitable water treatment system is installed if the qua...

Страница 18: ...n be connected to even previously installed hot water gene rators provided they are of adequate output power but care must be taken to ensure correct water flow directions They can also be easily inte...

Страница 19: ...bisolar 3S 5 Riello Thermoidro 6 Water treatment unit 7 Electronic pump 8 Riello Solar MR and expansion vessel 9 Room thermostat 10 Distribution manifold 11 Two way valve 12 Thermostatic mixer valve 1...

Страница 20: ...caping from the safety valve b Use a thermostatic mixer valve to limit the domestic hot water outlet temperature b If the pressure in the solar heating circuit drops do NOT top up with water but use t...

Страница 21: ...r socket 8 mm SRS Solar controller temperature sensor socket 16 mm It is essential to perform the following checks before starting up or testing the functioning of the combination storage cylinder In...

Страница 22: ...struction manual for the controller Start up the boiler to provide auxiliary heating for the combination storage cylinder Once the system has been started up perform the fol lowing checks Solar heatin...

Страница 23: ...used for an extended period of time prepare it for shut down as follows Shut down the boiler as instructed in its own manual Turn the system s main power switch OFF Drain the solar water circuit Close...

Страница 24: ...ly to the storage cylinder s valve group and to any associated boiler OFF at the main switch and at the control panel Close the shut off cocks for the domestic hot water cir cuit Drain the storage cyl...

Страница 25: ...he heat generator or solar heating system The pump is malfunctioning There is lime scale or sludge in the tank Water temperature is low Check the setting and condition of the thermostat Check the pump...

Страница 26: ...o low Set a T of 8 10 C There is lime scale or sludge in the tank Check and clean as necessary The flow rate is too high Reduce pump speed and turn the flow rate adjustment screw on the valve group to...

Страница 27: ...GENERAL 27...