Riello 7000.1000/S Скачать руководство пользователя страница 3

3

Riello 7000

  As soon as you open the packaging, check imme-

diately that the contents are all present and unda-

maged. Contact the Riello reseller from whom you 

purchased the product if you notice any problems.

  This Riello 7000 solar storage tank must be installed 

by a qualified installer according to Law 46 of the 5th 

March 1990. On completion of the installation, the 

installer must issue the owner with a declaration of 

conformity confirming that the installation has been 

completed to the highest standards in compliance 

with the instructions provided by Riello in this in-

struction manual, and that it conforms to all appli-

cable laws and standards.

  This Riello 7000 solar storage tank must only be used 

for the purpose specified by Riello and for which it 

is designed. Riello declines all responsibility, con-

tractual or other, for damage to property or injury to 

persons or animals caused by improper installation, 

adjustment, maintenance or use.

  If you notice any water leaking from the tank, di-

sconnect it immediately from the mains electricity 

supply, shut off the water supply, and notify your 

Riello  Technical  Assistance  Centre  or  a  qualified 

technician immediately.

  This storage tank must be serviced at least once a 

year.

  If the solar storage tank is not going to be used for 

an extended period of time, prepare it for shutdown 

as follows:

  - Turn the system’s main power switch OFF.

  - Drain the solar heating circuit, if connected, and 

the heating system.

  - Close the shut-off cocks for the water circuit.

  - Shut down the boiler as instructed in its own ma-

nual.

  If the storage tank is used as part of a solar heating 

system, you will need to pre-mix separately purcha-

sed anti-freeze (propylene glycol) with water in a 

percentage varying from 30% to 50% as instructed 

in the relevant Riello installation and maintenance 

manual.

  Only  fill  the  solar  heating  system  with  water  and 

glycol premixed in the percentages specified in the 

Riello installation and maintenance manual.

  This instruction manual is an integral part of the sto-

rage tank. It must be kept safe and must ALWAYS ac-

company the appliance, even if it is sold to another 

owner or transferred to another user or to another 

installation. If you damage or lose this manual, or-

der a replacement immediately from your local Riello 

Technical Assistance Centre.

The operation of any appliance that uses electrical power 

and water demands that a number of fundamental safety 

precautions be respected. In particular:

  Do  not  allow  children  or  infirm  persons  to  operate 

the storage tank unsupervised.

  Do not touch the storage tank when barefoot or wet.

  Never clean or service the storage tank without first 

disconnecting it from the mains electricity supply by 

turning the main power switch and the control panel 

switch OFF.

  Do not interfere with any control devices without 

specific authorisation and instructions from the ma-

nufacturer.

  Never pull, disconnect, or twist the electrical cables 

coming from the appliance even if it is disconnected 

from the mains electricity supply.

  Do not expose the storage tank to the elements.

  It is not designed for use outdoors.

  Do not leave packaging material within the reach of 

children, since it can become a potential hazard.

  If the pressure in the solar heating circuit drops, do 

not top up with water alone, since this increases the 

risk of damage from freezing.

  Do not use connections or safety devices or fittings 

(expansion vessels, pipes, insulation) that are not 

specifically designed and tested for use in solar hea-

ting installations.

1   Safety precautions

2   General safety information

Содержание 7000.1000/S

Страница 1: ...cod 068549EN rev 8 06 2015 Solar storage tanks 7000 EN INSTALLATION INSTRUCTIONS...

Страница 2: ...ng of your Riello 7000 solar storage tank Please accept our renewed thanks for your purchase Riello MODEL CODE RIELLO 7000 1000 S 4383408 RIELLO 7000 1500 S 4383409 RIELLO 7000 2000 F 4383410 RIELLO 7...

Страница 3: ...pylene glycol with water in a percentage varying from 30 to 50 as instructed in the relevant Riello installation and maintenance manual Only fill the solar heating system with water and glycol premixe...

Страница 4: ...f coil Maximum working pressure of cylinder Maximum working temperature of cylinder Heat loss Electrical consumption Power supply l kW l 1 bar C bar C kW 24h W V Hz Obligatory ground connection Serial...

Страница 5: ...il Riello 7000 1000 S and 1500 S models Riello 7000 2000 F 3000 F 5000 F models 1 Soft polyurethane insulation 100 mm 2 Vent outlet fitting 1 1 4F 3 Outlet return fittings 1 1 2F 4 Probe wells 1 2 F 7...

Страница 6: ...ange diameter external internal 290 220 290 220 290 220 mm Probe well diameter 8 mm Coil water capacity 14 6 21 6 l Coil heat exchange surface area 2 6 3 8 m2 Power absorbed by coil 68 99 kW Heating h...

Страница 7: ...000 2000 F 3000 F 5000 F models Heat exchanger coil KIT PRESSURE DROP Riello 7000 2000 F 3000 F 5000 F models only PRESSURE DROP mbar FLOW RATE m3 h 8 Dimensions and weight Riello 7000 1000 S Riello 7...

Страница 8: ...The counter flange comes ready bolted to the tank s flange and fitted with a seal The second package contains another plastic bag with the elegantly finished polyurethane insulation fitting sleeves f...

Страница 9: ...1 2 1 1 Riello 7000 2000 F 3000 F 5000 F Riello 7000 1000 S 1500 S Make sure that any lifting equipment is of adequate capa city to lift and move the storage tank Cut the straps 1 to remove the tank...

Страница 10: ...e holes on the inside of the insulation Secure the insulation in place with the zips 2 at the edges of the two sections Perforate the insulation at the fittings and fit the insu lation sleeves 3 Fit t...

Страница 11: ...iler OFF at the main switch and at the control panel Close the shut off cocks for the heating water circuit Drain the storage tank or its secondary circuit if a pri mary circuit is connected EXTERNAL...

Страница 12: ...0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore lia...