Once the storage tank is correctly positioned inside the 

room where it is to be installed, proceed to fit the insula-

tion and the accessories to complete the tank.

Proceed as follows:

-  Unpack all the material from the second package.

-  Wrap the insulation (1) around the storage tank, careful-

ly lining up the fittings with the holes on the inside of 

the insulation. Secure the insulation in place with the 

zips (2) at the edges of the two sections.

-  Perforate the insulation at the fittings and fit the insu-

lation sleeves (3).

-  Fit the flange cover (4).

-  Finally, fit the insulation top panel (5) and cover it with 

the cover (6).

   With all the insulation in place, apply the serial 

number plate, data plate and product identification 

plate to ensure that the storage tank can be accura-

tely identified (see the plate positions on page 14).

13   Fitting the insulation (Riello 7000.2000/F - 3000/F - 5000/F)

Содержание 7000.1000/S

Страница 1: ...cod 068549EN rev 8 06 2015 Solar storage tanks 7000 EN INSTALLATION INSTRUCTIONS...

Страница 2: ...ng of your Riello 7000 solar storage tank Please accept our renewed thanks for your purchase Riello MODEL CODE RIELLO 7000 1000 S 4383408 RIELLO 7000 1500 S 4383409 RIELLO 7000 2000 F 4383410 RIELLO 7...

Страница 3: ...pylene glycol with water in a percentage varying from 30 to 50 as instructed in the relevant Riello installation and maintenance manual Only fill the solar heating system with water and glycol premixe...

Страница 4: ...f coil Maximum working pressure of cylinder Maximum working temperature of cylinder Heat loss Electrical consumption Power supply l kW l 1 bar C bar C kW 24h W V Hz Obligatory ground connection Serial...

Страница 5: ...il Riello 7000 1000 S and 1500 S models Riello 7000 2000 F 3000 F 5000 F models 1 Soft polyurethane insulation 100 mm 2 Vent outlet fitting 1 1 4F 3 Outlet return fittings 1 1 2F 4 Probe wells 1 2 F 7...

Страница 6: ...ange diameter external internal 290 220 290 220 290 220 mm Probe well diameter 8 mm Coil water capacity 14 6 21 6 l Coil heat exchange surface area 2 6 3 8 m2 Power absorbed by coil 68 99 kW Heating h...

Страница 7: ...000 2000 F 3000 F 5000 F models Heat exchanger coil KIT PRESSURE DROP Riello 7000 2000 F 3000 F 5000 F models only PRESSURE DROP mbar FLOW RATE m3 h 8 Dimensions and weight Riello 7000 1000 S Riello 7...

Страница 8: ...The counter flange comes ready bolted to the tank s flange and fitted with a seal The second package contains another plastic bag with the elegantly finished polyurethane insulation fitting sleeves f...

Страница 9: ...1 2 1 1 Riello 7000 2000 F 3000 F 5000 F Riello 7000 1000 S 1500 S Make sure that any lifting equipment is of adequate capa city to lift and move the storage tank Cut the straps 1 to remove the tank...

Страница 10: ...e holes on the inside of the insulation Secure the insulation in place with the zips 2 at the edges of the two sections Perforate the insulation at the fittings and fit the insu lation sleeves 3 Fit t...

Страница 11: ...iler OFF at the main switch and at the control panel Close the shut off cocks for the heating water circuit Drain the storage tank or its secondary circuit if a pri mary circuit is connected EXTERNAL...

Страница 12: ...0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore lia...

Отзывы: