DESCRIPTION OF THE APPLIANCE

The 

R

 

RBS 1S

 boiler produces domestic hot water for storage 

purposes.

 

Their most important technical features are:

 

− the storage cylinder and coil are specially designed and 

shaped for optimum performance in terms of stratification, 

heat exchange and replenishment times

 

− internal glazing, bacteriologically inert, to ensure the max-

imum hygiene of treated water, reduce limescale deposits 

and make cleaning operations easier

 

− CFC-free polyurethane insulation and an elegant external 

casing reduce heat loss

 

− a flange is provided for easy cleaning and maintenance of 

the anti-corrosion magnesium anode.

 

IDENTIFICATION

R

 

RBS 1S

 storage cylinders are identified by:

Data plate

This lists the technical specifications and performance of the 

product.

BALLON

Modèle

Model

Numéro de série

Code

Année

kW

kW

Mbtu/h

T067872FE

T067872FE

WATER TANK

Serial number

Code

Year

Mbtu/hr

Numéro de série

Serial number

Modèle

Model

l

gal

Capacité du ballon

Storage cylinder capacity

bar

psi

Test pressure (of storage cylinder not counting)

Pression T estérieure (ballon pas consideré)

Maximun inlet temperature

Température maximale en entrée

bar

psi

Pression service max.

Maximum working pressure of storage cylinder

m

2

SQ FT

Surface serpentin 

Coil heat exchange surface area

Puiss. absor. serp.

Power abs. by coil

Mise à la terre obligatoire 

-

Mandatory ground connection

RIELLO S.p.A. - ITALY

RIELLO S.p.A. - ITALY

l/1’

gal/1’

Domestic hot water production [∆T 35°C / 63°F]

Production eau chaude sanitaire [ΔT 35°C / 63°F]

Power absorbed by coil

[T° primary 80°C ΔT 10°C / 176°F ΔT 18°F]

Puissance absorbée serpentin

[T° Primaire 80°C ΔT 10°C / 176°F ΔT 18°F]

5020563

Conforms to UL Std. 174. 

Cert. to CSA Std. C22.2 No.110

Serial number plate

This specifies the serial number and model.

 

9

NOTE

: If these plates or any other means clearly identifying 

the product are defaced, removed or lost, proper installa-

tion and servicing may be rendered difficult.

SYSTEM LAYOUT

UAC

RC

MC

EAF

SB

P

M

UAC

SC

1

6

3

2

5

4

Domestic water storage tank

Coil

Flange for heater inspection

Insulation

Cover

Relief valve

 

P Socket

M Guide

UAC 

Domestic hot water outlet

EAF 

Domestic cold water inlet

SB 

Storage cylinder drain

MC 

Outlet from boiler

RC 

Return to boiler

SC 

Safety valve drain

Содержание 20167551

Страница 1: ...cod 20176041 rev 6 05 2021 RBS 50 80 119 1S RBS 1S USA INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Страница 2: ...which could cause severe personal injury death or substantial property damage if ignored 9CAUTION indicates the presence of hazards or unsafe practices which could cause minor personal injury or prod...

Страница 3: ...istance Service to request a service call under warranty 9This manual should be maintained in legible condition and kept adjacent to the boiler or in a safe place for future refer ence 9WARNING Failur...

Страница 4: ...pressure of storage cylinder not counting Pression T est rieure ballon pas consider C F Maximun inlet temperature Temp rature maximale en entr e bar psi Pression service max Maximum working pressure...

Страница 5: ...nch Height with insulation 44 9 16 72 1 8 64 27 32 inch Insulation thickness 2 1 16 2 1 16 2 1 16 inch Total net weight 139 236 313 lbs Diameter length of magnesium anode 1 9 16 12 3 16 1 9 16 20 7 16...

Страница 6: ...int reference with primary exchanger at the indicated delivery temperature and with the indicated delta T Coil delivery temperature 176 F T 36 F 23 25 33 min 176 F T 18 F 18 20 27 min 158 F T 36 F 37...

Страница 7: ...l RBS 1S 50 80 119 Circulator Flow 7 4 16 6 10 24 5 13 34 9 GPM Domestic Outlet 115 140 115 140 115 140 115 140 115 140 115 140 F Boiler Heating Capacity Btu h 40000 131 116 162 138 212 181 GPH 60000...

Страница 8: ...DROP 400 500 600 200 300 100 0 0 1000 1500 500 3000 3500 2500 2000 4500 5000 4000 6000 6500 7000 7500 8000 5500 0 130 260 390 520 650 780 910 1040 1170 1300 1430 1560 1690 1820 1950 2080 mbar in wc 16...

Страница 9: ...nstruction manual Bar code label Hydraulic test certificate Relief valve 9The instruction manual is an integral part of the solar storage cylinder Once located read it thoroughly and keep it safe 9For...

Страница 10: ...can be installed in any room where there is no specific requirement for an electrical protection rating higher than IP X0D X X X Y Z DESCRIPTION RBS 1S X 300 mm 11 13 16 inch Y 600 mm 23 5 8 inch Z 70...

Страница 11: ...d 7 10 120 180 Hard 10 180 Very Hard If the water hardness exceeds 7 grains the water will require a water softener Soften water to no lower than 5 grains If the water hardness is 0 to 1 grains than t...

Страница 12: ...0 mm 5 1 8 5 1 8 5 1 8 inch A 171 171 208 mm 6 11 16 6 11 16 8 3 16 inch B 243 318 304 mm 9 9 16 12 1 2 11 15 16 inch C 561 731 718 mm 22 1 16 28 3 4 28 1 4 inch D 713 1092 1024 mm 28 1 16 43 40 5 16...

Страница 13: ...off Devices for Hot Water Supply Systems ANSI Z21 22 This valve must be marked with a maximum set pressure not to exceed the marked maximum working pressure of the water heater Install the valve into...

Страница 14: ...ief valve SC Safety valve drain 9NOTE These illustrations are intended to show the piping concept of the system only the installer is responsible for all equipment and details required by local codes...

Страница 15: ...ed the above checks have been completed satisfactorily re start the system and verify its performance 15 TEMPORARY SHUTDOWN If you are going away for a short period of time like a weekend or a short h...

Страница 16: ...rage cylinder s DHW secondary water circuit 17 CLEANING AND REMOVING INTERNAL COMPONENTS EXTERNAL CLEANING Clean the outside of the storage cylinder with a soft cloth damped in soapy water To remove s...

Страница 17: ...ghtening torque of 10 Nm 2 0 Fill the storage cylinder s DHW secondary circuit and check that there are no leaks from any of the seals Check the performance of the storage cylinder Reposition and manu...

Страница 18: ...thermostat is set too high 20 START UP The heater commissioning must be performed by Technical Assis tance Service personnel Under certain circumstances such as after long periods of disuse the user...

Страница 19: ...19 END USER END USER...

Страница 20: ...5 Meadowpine Blvd Mississauga ON L5N6H6 CANADA Technical Support Hotline 1 800 474 3556 Professional Resources www riello com The manufacturer strives to continuously improve all products appearance d...

Отзывы: