Riello 20091302 Скачать руководство пользователя страница 4

4

 

sonnel in compliance with the reference regulations and 

standards.   

 

9

The burner should be purchased separately, this manu-

al contains only information regarding the boilers and the 

boiler warranty does not extend to the burner. It is neces-

sary to consult the burner's instruction manual and have 

the Warranty Certificate issued for the burner by the dealer 

where it was purchased.

 

9

Before starting the burner, make sure that the front door of 

the boiler is closed tight and that the burner connections 

have been carried out correctly.

 

9

Do not touch the hot water pipes and the flues gases dis-

charge pipe when the boiler is running.

1.1 

General warnings

The boiler models that are the subject of this manual are sup-

plied disassembled of the boiler body.

 

9

The cast iron boilersRTT 163-355 are designed for heating 

using water and/or supplying hot water systems and have 

been designed with technologies and materials suitable for 

this purpose. Use the product only for this intended use.

 

9

The installation of the appliance should be carried out on a 

base that is suited to the weight and the dimensions.

 

9

The base of the boiler should be positioned and oriented in 

such a way as to leave sufficient space on the sides of the 

appliance to meet safety requirements and permit access to 

the boiler for maintenance and repairs.

 

9

The commissioning and initial ignition of the boiler should 

only be carried out by specialised installers.

 

9

It is forbidden to put or pump water into the boiler or the 

hydraulic system when the appliance is running and is hot.

 

9

Before putting water in the boiler or the system, it is neces-

sary to wait for the water temperature to reach 40° C. When 

putting water into the system, always run the circulation 

pump to prevent breaking the elements.

 

9

When the boiler is off for a long period or when carrying out 

repairs, maintenance or cleaning, the electrical supply must 

be disconnected using the master switch.

 

9

Especially in summer, when the boiler is off for a long pe-

riod, to avoid problems of incrustation in the circulation 

pumps, the boiler must be switched on 1-2 times a month 

and the circulation pumps operated for at least 5 minutes. 

Limescale in the water can cause problems if the pump is 

unused for a long period.

 

9

Choose a boiler with the right dimensions for the project 

in full compliance with applicable regulations. If the wrong 

size is chosen, the performance will suffer.

 

9

The RTT 163-355 boilers are only to be used for heating. For 

the production of domestic hot water, it is necessary to use 

a storage heater or another heat exchanger. To attain an ap-

propriate performance, pay special attention to the size of 

the domestic hot water circuit.

 

9

The RTT 163-355 boilers are delivered without the burner. To 

choose the most suitable burner and to keep the perfor-

mance at a high level, contact technical personnel.

 

9

If the boiler goes into lockout automatically because of over-

heating, do not put cold water inside to get it going again. 

Wait until the boiler cools down, and try to restart it. If this 

does not happen, contact the Technical Assistance Service.

 

9

Periodically check the boiler and the burner. If these period-

ic controls are not carried out, the performance will worsen 

and there will be an increase in fuel consumption. The peri-

odic and annual controls of the boiler should be carried out 

precisely and at the scheduled time. Natural gas is a clean 

fuel and does not dirty the appliance so much. Liquid fuel 

burners, on the other hand, get the appliance very dirty and 

the boiler controls and maintenance operations are neces-

sary to ensure a high performance and a long life.

 

9

Repairs and periodic controls of the boilers RTT 163-355 

should be carried out by specialised technicians. This man-

ual contains an explanation of the user's responsibilities 

and the information required for using the boiler. Beyond 

these operations, the boiler should only be commissioned 

by the user or by one of our technicians. Do not try to adjust 

the boiler or tamper with any components.

 

9

The mains electrical connections to the boiler room, to the 

burner and to the boiler itself, the earthing of the control 

panel and the boiler should be carried out by qualified per-

Содержание 20091302

Страница 1: ...cod Doc 0079321 rev 0 03 2016 RTT 163 355 EN INSTRUCTIONS FOR THE INSTALLER AND FOR THE TECHNICAL ASSISTANCE CENTRE ...

Страница 2: ...trusted to a R Technical Assistance Centre which is specifically capable of carrying out routine maintenance keep it running at maximum efficiency with low running costs and which has original spare parts if required This instruction booklet contains important information and suggestions that should be observed for easy installation and better use of the RTT 163 355 boiler Thank you once again Rie...

Страница 3: ...n of the boiler room 12 1 16 Gas side resistor and output temperature of combustion gases 13 1 17 Instructions for use 13 1 18 Conveyance and discharge of the boiler water 14 1 19 Instructions for disposing of the product 14 1 20 Fire prevention regulations for the boiler room 14 1 21 Controls and starting the boiler 14 1 22 Maintenance instructions 15 1 23 Cleaning the boiler 15 1 24 Burner door ...

Страница 4: ...od to avoid problems of incrustation in the circulation pumps the boiler must be switched on 1 2 times a month and the circulation pumps operated for at least 5 minutes Limescale in the water can cause problems if the pump is unused for a long period 9 9Choose a boiler with the right dimensions for the project in full compliance with applicable regulations If the wrong size is chosen the performan...

Страница 5: ... the fact that the boiler is as sembled on site Handling or changing its position are easy and do not require the breaking of walls etc The RTT 163 355 boilers have been produced with a special iron alloy EN GJL 200 which provides a high degree of resistance to corrosion and thermal expansion This special material guaran tees the boilers have a long working life Thanks to the special horizontal ga...

Страница 6: ...nput output coupling G 3 DN Boiler gas volume 142 17 170 43 198 69 226 95 255 21 283 47 311 73 dm3 lt 0 142 0 170 0 199 0 277 0 255 0 283 0 312 m2 Combustion chamber volume gas side 101 89 122 15 142 4 162 65 182 91 203 16 223 41 dm3 lt 0 102 0 122 0 142 0 163 0 183 0 203 0 223 m2 Safety limit thermostat 110 C Type of fuel Natural gas I2H gas Extra Light Fuel Oil comb liquid Flue gases output temp...

Страница 7: ...of the boiler room For the delivery of the unassembled appliances the various sec tions and the various components are delivered inside a pallet while the casing the insulating layer and other elements are delivered in a box The assembly of the boiler is carried out by specialist technicians Burner box pallet and cardboard box Casing walls and insulat ing covering wood box Cast iron boiler element...

Страница 8: ... 1 605 1 750 1 890 2 035 L L 200mm 200mm 800mm A Characteristics of the base it should be made of BS 25 fiber concrete it should have the indicated dimensions it should not be covered with a slippery material like ce ramic etc and acoustic insulation should be made before the base In the RTT 163 355 boilers the door of the burner can open on both sides For this reason equal free distances are spec...

Страница 9: ...ilation 9 9Arrange for the creation of a branching of the water supply line near the boiler and a drainage system for draining the boiler water 9 9It is strongly recommended not to install extraction systems air conditioning systems or other devices in the boiler room that as a secondary effect could cause the so called vac uum effect and reduce the draught force of the boiler with the main conseq...

Страница 10: ...alve connecting the supply line and the return line of the heating system to adjust the flow rate of the water in the system according to the desired performances The amount of water in the system should be such that there is always water in the boiler Otherwise the boiler could be subject to corrosion If the boiler is not used in winter in order to prevent damage from freezing use an anti freeze ...

Страница 11: ...a differ ence of level H between the output of the fuel tank 9 and the burner input 10 greater than 4 m When the boiler is not being used empty the fuel tank to prevent corrosion Low flue edge Bad surface dust etc Blocking gas flow Dust obstacling cleaning Flue which is not available for cleaning Weakly closed door Too long pipe Cleaning door leaking air Objects blocking gas flow Connection betwee...

Страница 12: ...so operate in summer The maximum temperature of the boiler room should be 32 C and the room should be protected from frost Type of boiler Combustion gas pipe dimensions mm Flue gases pipe methane gas m RTT 163 180 30 27 43 59 RTT 195 180 43 33 62 39 RTT 227 250 15 78 22 72 RTT 259 250 20 55 29 59 RTT 291 250 25 94 37 35 RTT 323 250 31 96 46 02 RTT 355 250 38 61 55 59 1 13 Control panels that can b...

Страница 13: ...esistance mbar 100 130 180 200 220 160 10 20 30 40 50 60 70 80 90 100 Exit flue gas temperature C Load 1 17 User instructions Heating system In the heating system the difference between the direct supply temperature and the water return temperature should not ex ceed 20 C The temperature of the return water should higher than 50 C Use the boiler s protection pump to increase the tem perature of th...

Страница 14: ...3 355 boilers should be positioned and installed par ticularly carefully and in conformity with fire safety regulations When installing and using the boiler a safety distance of 200 mm must be observed from class B C1 and C2 flammable ma terials For class C3 materials that easily catch fire namely materials that burn quickly and that keep combusting even after removal from the source of the igniti...

Страница 15: ...checks We recommend these checks be carried out once every three months Periodic checks are carried out by the techni cians as follows Checking and cleaning if necessary of the combustion chamber and the passageways of the boiler smoke Checking for water leaks going into and coming out of the boiler and the checking the seal of the flue gases pipe fitting Checking the valves Checking the pumps Che...

Страница 16: ...ion 1 is composed of a special thermal ceramic that can withstand up to 1250 ºC and is safe for people to use Be very careful when transporting the insulating plate A ceramic fibre insulating cord is inserted in the door groove The cord has the function of preventing leaks between the door and the front element of the boiler After cleaning or repair work put back the door fixing it solidly to the ...

Страница 17: ... 3483200 RTT 195 RLS 28 3483200 RTT 227 RLS 28 3483200 RTT 259 RLS 28 3483200 RTT 291 RLS 38 3484100 RTT 323 RLS 38 3484100 RTT 323 RLS 38 3484100 RTT 355 RLS 38 3484100 RTT 355 RLS 38 3484100 GAS BURNER BOILER BURNER MODEL CODE RTT 163 BS 4D 3761816 RTT 195 BS 4D 3731816 RTT 227 RS 34 MZ TC 3789000 RTT 259 RS 34 MZ TC 3789000 RTT 291 RS 34 MZ TC 3789000 RTT 323 RS 44 MZ TC 3789100 RTT 323 RS 44 M...

Страница 18: ...nsported ensure at least the normal storage conditions non aggressive environment air humidity less than 75 temperature between 5 and 55 C low dust levels and the prevention of damage due to biological factors Do not force the cover elements and the boiler panels in the storage phase or when being transported For the transportation of the boiler always use lift trucks trans pallets or other means ...

Страница 19: ...ormation Retailer Mr Address Tel Technical Assistance Centre Mr Address Tel Installer Mr Address Tel Date Intervention Fuel supplier Mr Address Tel Date Qty supplied Date Qty supplied Date Qty supplied Date Qty supplied ...

Страница 20: ...ago VR Tel 0442630111 Fax 044222378 www riello it As part of the company s ongoing commitment to perfecting its range of products the appearance dimensions technical data equipment and accessories may be subject to variation ...

Отзывы: