CHARACTERISTIC CURVES FOR PUMP

3

2,5

2

1,5

1

0,5

0

0

0,5

1

1,5

2

2,5

Prevalenza (m

)

Portata (m

3

/h)

PUTTING INTO SERVICE

Proceed as follows to install the recirculation kit.

 - Close the cold water inlet ball valve (3) and the hot wa-

ter outlet ball valve (4).

 - Unscrew and remove the 3/4” plug (1).

 - Install the recirculation accessory. Screw on and fittings 

and tighten the watertight fitting.

 - Insert temperature sensor S1 in its socket (2) and con-

nect it to the controller as shown in the electric wiring 

diagram.

 - Fill and pressurise the circuit.

 - Check that the circuit is watertight.

 - Switch on the DHW mixer.

 - Go to the controller menu 6. “Special functions”, and 

set recirculation ON in parameter 6.6.1.1.

 - Go to the controller menu 4. “Settings”, and in parame-

ter 4.4 set the required recirculation functioning para-

meters. (See the manual supplied with the DHW mixer 

for default settings.)

 - Check the correct functioning of the system.