7   Receiving the product

The solar storage cylinders Riello 7200/2 1500 HV PLUS are 

supplied in a single package, protected by a nylon bag 

and put on wood pallets.

The two magnesium anodes are supplied in a cardboard

box on the pallet

7000/2 1500 HV PLUS

7000/2 2000 HV PLUS

Model Riello 7200/2 2000 HV PLUS are supplied in two sep-

arate packages:

- the first package is composed of the painted tank, pro-

tected by a nylon bag and put on wooden pallets.

- the second package, also protected by a nylon bag, is 

composed of the polyurethane insulation with an el-

egant outer covering, the outer trim rings of the pipe 

coupling, the top cover, the flange covers, the identifi-

cation labels and the documentation.

The following material is supplied in a plastic envelope 

inside the package:

- Instruction booklet

- Garanty certificate and label with bar code

- Catalogo ricambi

- Hydraulic test certificate

- n° 3 adjustable feet

- n° 2 threaded inserts for fixing solar controller (accessory).

The two magnesium anodes are supplied in a cardboard

box on the pallet

    The instruction booklet is an integral part of the 

storage cylinder and it is recommended that it be 

read and kept safe.

INSTALLING THE MAGNESIUM ANODES

Proceed as follows to install the magnesium anodes:

- Remove the protective plugs

- Fit the two magnesium anodes in the fittings (1) and (2)

- Screw in the magnesium anodes using a suitable span-

ner.

The two magnesium anodes are supplied in a cardboard

box on the pallet

NOTE: 

Tighten to a torque of 25 Nm.

8   Handling

The handling of the storage cylinder is carried out with 

equipment that is suitable for the weight of the appli-

ance.

To remove the storage cylinder from the pallet, cut the 

straps (1). 

For models 7000/2 1500 HV PLUS these can be found under 

the insulation near the hinges.

To lift the 7000/2 1500 HV PLUS storage cylinders, there is a 

plug (2) with a hole where a lifting hoop (Ø 10 mm) suita-

ble for the weight of the tank can be inserted.

To lift the 7000/2 2000 HV PLUS storage cylinders, after re-

moving the insulation, bind the high part of the boiler 

with a cord that can bear the weight and carefully lift it.

    It is possible to dismantle the insulation covering to 

make it easier to get through the door of the boiler 

room.

    Use suitable accident-prevention protections.

    It is forbidden to dispose of the packaging material 

and keep within children's reach, as it may be a po-

tential source of danger.

1

2

2

Содержание 20052784

Страница 1: ...cod 20055743_EN rev 2 05 2016 Solar storage cylinders 7200 2 1500 2000 HV PLUS EN INSTALLATION INSTRUCTIONS...

Страница 2: ...ternal components 11 14 Recycling disposal 11 Index Dear Installer thank you for choosing a Riello 7200 2 HV PLUS solar stor age cylinder a modern high quality product providing you with the utmost we...

Страница 3: ...operations be carried out Drain the solar heating circuit Close the shut off devices of the water system Switch off the boiler as described in the appli ance s instruction booklet Turn off the system...

Страница 4: ...ersion 250 305 W 6 7 32 kWh 24h Insulation type Soft PU shells Useful non solar volume Vbu 525 800 l According to DIN 4708 to get domestic hot water with T 20 C 80 60 C on the heat exchanger please ob...

Страница 5: ...4500 5000 5500 6000 Mod 1500 Mod 2000 Pressure drop TOP COIL Pressure drop BOTTOM COIL PRESSURE DROP mbar FLOW RATE l h PERDITA DI CARICO mbar PORTATA l h 600 650 700 550 500 450 400 350 300 250 200...

Страница 6: ...ric resistor socket not supplied AD1 AD2 Magnesium anode 1500 HV PLUS 2000 HV PLUS The solar storage cylinder Riello 7200 2 HV PLUS is not equipped with load circulators which should be appropriately...

Страница 7: ...rain 1 1 2 F 1 1 2 F Psc Diameter length boiler probe socket 1 2 F 1 2 F mm Psr Diameter length solar regulator probe socket 1 2 F 1 2 F mm RE Electric resistor socket not supplied 1 1 2 F 1 1 2 F AD1...

Страница 8: ...is an integral part of the storage cylinder and it is recommended that it be read and kept safe INSTALLING THE MAGNESIUM ANODES Proceed as follows to install the magnesium anodes Remove the protectiv...

Страница 9: ...e solar heating circuit is completely vented The cold pressure of the equipment is about 3 bar The safety valves intervenes at 6 bar The piping of the hydraulic supply are insulated in full respect of...

Страница 10: ...he proce dure reported above is difficult to do Periodic maintenance which is essential for safety purposes the efficiency and the life of the solar storage cylinder provides reduced consumption and k...

Страница 11: ...nesium anode and replace it if necessary Once the cleaning operations are finished reassemble all the components following the above instructions in the reverse order NOTE the tightening torque of the...

Страница 12: ...0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore lia...

Отзывы: