ENGLISH
ACCESSING INTERNAL COMPONENTS
Only personnel from Technical Assistance Service or
professionally qualified heating engineers are allowed to
access components inside the control panel.
Proceed as follows if you need to access components
inside the control panel:
- Turn the system OFF at the mains power switch
- Remove the top panel (1) by pulling it outwards.
1
b
Carefully unwind the thermostat cables and route them
through the relevant grommets. Insert the thermostat
sensors in the corresponding sockets in the boiler. Fix the
sensors securely in place. Use the cable straps provided
to secure the sensor cables.
Spring clip
Cable
Sensor
r
Radius
≥
20 mm
Sensor socket