pag. 10 / 57 0MNMHEM30RUENUB 00
1
Insert the forks of the fork-lift truck in the lower part of the device, from the front or back, and ensure
that they stick out about 30 cm on the other side.
If a transpallet is used, raise the device only as much as is strictly necessary.
2
Secure the device to the transpallet or fork-lift before moving it.
Risk of overturning
In order to avoid the risk of the device overturning, ensure that it is firmly secured to the transpallet or fork-
lift truck by means of appropriate ropes before moving it.
When being moved the cabinet should be handled with care; knocks or drops can damage it. Once in position,
remove the packaging carefully in order not to scratch the device.
The packaging should be removed as follows:
1.
Cut the bands
2.
Slide away the carton from above.
3.
Remove the screws securing the cabinet to the wooden base.
4.
If using a transpallet, remove the device from the pallet and set it on the floor, using the same
precautions as set out in the section on Handling.
2.
Installation environment
The MASTER HE and the battery cabinet have been designed for indoor installation. The choice of premises for
installation should comply with the points set out below.
2.1
Ambient conditions:
ensure that the floor can support the weight of the UPS and of any battery cabinet that may be used;
avoid dusty environments;
avoid narrow environments that could hinder normal maintenance operations;
avoid placing the device in areas exposed to direct sunlight or heat;
ensure that the ambient temperature conforms to the following:
minimum operating temperature:
0 °C
maximum temperature for 8 hours a day:
+ 40°C
average temperature for 24 hours:
+ 35°C
max relative humidty:
95 % without condensation
Max installation height:
1000 m at rated power
(-1% power for every 100 m above 1000 m) max 4000 m
2.2
Dimensions of the premises
For the mechanical dimensions of the cabinets, refer to the
“INSTALLATION DRAWINGS”
supplied with the UPS
and with the battery cabinet, if present. These drawings provide the following data:
the position of the holes in the base to secure the device to the floor, if applicable;
the view of the floor support for the sizing of a structure to raise the cabinet, if applicable;
the position of cable entry;
the position of the fans on the top of the UPS, for the positioning of a structure to convey the warm air
discharged by the equipment outside the premises, if applicable;
the input, output and battery cables section;
the power dissipated by the equipment (kW).
Содержание MASTER HE
Страница 2: ...pag 2 57 0MNMHEM30RUENUB 00 RPS SpA Viale Europa 7 37045 Legnago VR Italy www riello ups com ...
Страница 6: ...pag 6 57 0MNMHEM30RUENUB 00 This page is left blank intentionally ...
Страница 25: ...0MNMHEM30RUENUB 00 pag 25 57 This page is left blank intentionally ...
Страница 35: ...0MNMHEM30RUENUB 00 pag 35 57 This page is left blank intentionally ...
Страница 50: ...pag 50 57 0MNMHEM30RUENUB 00 This page is left blank intentionally ...
Страница 52: ...pag 52 57 0MNMHEM30RUENUB 00 This page is left blank intentionally ...