Fail:
We turn the key but the dashboard doesn’t turn ON, always is black.
Battery charge.
Connect diagnosis software to the bike. If
display is not connected
check
CAN drive unit, check DC/DC 48V connector.
Controller shows the following errors:
0x2F :
(CAN) Communication fault btw. VCU and HMI, Deleted after T15
reset if fault is inactive,
0xAF :
Unknown / untrusted component identified, Deleted when fault
becomes inactive,
Checks big dashboard connector:
Dashboard connectors are placed rear of the front light, on the lower fork plate.