Page 14 of 79
Technical Documentation and
User Instructions
Laser Mirror Scanner LMS-Q280i
3.3 Laser Safety
The laser scanner instrument
LMS-Q280i
is classified as
Class 1
laser product
in compliance with the International Eye safety regulation
IEC60825-
1:1993+A1:1997+A2:2001
and the European Eye safety regulation
EN60825-
1:1994+A1:2002+A2:2001
Safety of Laser Products
,
Equipment Classification,
Requirements and User´s Guide
.
Class 1: Lasers which are safe under reasonably foreseeable conditions of
operation, including the use of optical instruments for intrabeam viewing
(IEC60825-1:2001, Sub-clause 8.2).
The labeling of the
LMS-Q280i
meets the requirements of the above standard
(IEC60825-1:2001, sub-clause 5.1 and 5.2). It is affixed two times near the front
pane on the LMS-Q280i.
CAUTION!
The invisible laser radiation inside
Aligning the infrared laser instrument with the lenses of CCD-cameras or
infrared night vision devices can result in damage to them and is therefore not
permitted.
Note: The laser beam exits the instrument via the front window as
indicated in the mechanical drawings.
IMPORTANT NOTE :
This classification is based on the condition that the laser
beam is continuously scanned. The LMS-Q280i emits laser radiation only, when
in scanning operation. In case of any fault of the driving mechanism, the laser is
switched off immediately.
the instrument may
exceed the accessible emission limits of laser class 1, thus
never
open the instrument’s housing
! Do not operate evidently damaged
instruments! If the instrument is handled incompetently, the
manufacturers absolve themselves from granting any guarantee or
insurance whatsoever.