background image

Scanner Specifications 

Scanner type:

Flatbed, color/monochrome

Photoelectric device:

CCD line sensor

Effective pixels:

2550 dots by 3510 dots at 300 dpi, 100%

Maximum document size:

216 mm by 297 mm (8.5 inches by 11.7 inches)

U.S. letter size or A4

Scanning resolution:

300 dpi

Output resolution:

50 dpi to 1200 dpi in 1 dpi steps

Color separation:

By switching light sources (R, G, B)

Reading sequence:

Monochrome mode:

One-pass scanning (Dropout color selectable

from Red, Green, or Blue)

Color page sequence mode:

Three-pass scanning (R, G, B)

Color byte sequence mode:

Three-pass scanning (R, G, B)

Color line sequence mode:

One-pass scanning (R, G, B)

Size:

50% to 200% in 1% steps

Image data:

8 bits per pixel per color saved as 8 bits per pixel per color,

maximum

Brightness:

7 levels

Text Enhancement Technology:

Enable/disable selectable

Halftoning process:

Enable/disable selectable
3 halftoning modes (A, B, and C)

4 dither patterns (A, B, C, and D)

for bi-level data or quad-level data

(2 downloadable dither patterns)

Gamma correction:

2 for CRT display

3 for printer

1 for user-defined

Document cover

Document glass (platen)

OPERATE button

RESET button ERROR light

READY light

OPERATE light

Carriage

(at home

position)

Transportation screw

DIP switch

Storage hole

Parallel port

AC inlet

Storage hole

Transportation screw

Terminator DIP switch

AC inlet

SCSI interface connectors

EPSON ACTIONSCANNER II

Scanners

10/95

ActionScanner II-1

Summary of Contents for ActionScanner ActionScanner II

Page 1: ...e One pass scanning R G B Size 50 to 200 in 1 steps Image data 8 bits per pixel per color saved as 8 bits per pixel per color maximum Brightness 7 levels Text Enhancement Technology Enable disable selectable Halftoning process Enable disable selectable 3 halftoning modes A B and C 4 dither patterns A B C and D for bi level data or quad level data 2 downloadable dither patterns Gamma correction 2 f...

Page 2: ...Input voltage range 198 264 VAC Rated current 0 3 A Rated frequency 50 to 60 Hz Input frequency 49 5 to 60 5 Hz Power consumption Approx 18W self testing Safety EMI and EMS 100 120 V model Safety UL1950 D3 CSA 22 2 No 950 D3 EMI FCC 15B Class B USA CSA 108 8 Class B CANADA 220 240 V model Safety EN60950 TÜV EN60950 Nordic Deviation NEMKO FIMKO DEMKO SEMKO EMI EN55022 CISPR Pub 22 Class B EMS IEC 8...

Page 3: ... ready to accept more data 11 29 BUSY OUT When this signal is high the scanner cannot receive or send data The signal is high 1 during data entry 2 when the scanner is not ready 3 when the scanner has an error 12 15 NC Not used 16 GND Logical ground level 17 C GND Scanner chassis ground 18 NC Not used 19 30 GND Twisted pair return signal ground level 31 INIT IN When this signal level becomes low t...

Page 4: ...us 0 DB1 I O 27 21 Data bus 1 DB2 I O 28 22 Data bus 2 DB3 I O 29 10 Data bus 3 DB4 I O 30 23 Data bus 4 DB5 I O 31 11 Data bus 5 DB6 I O 32 12 Data bus 6 DB7 I O 33 13 Data bus 7 DBP I O 34 20 Data bus parity TERMPWR 38 25 Termination power ATN I 41 17 Attention BSY I O 43 6 Busy ACK I 44 5 Acknowledge RST I 45 4 Reset MSG O 46 2 Message SEL I O 47 19 Select C D O 48 15 Control Data REQ O 49 1 Re...

Page 5: ...canner off and then back on to reset it Fatal Error This indicates one of thefollowingproblems One or more fluorescent lamps needs to be replaced The transportation screw has not been removed The scanner is broken Check that thetransportation screwhas been removed then push the RESET button If the scanner still does not operate properly try turning the scanner off wait 10 seconds and then turn it ...

Page 6: ...th the READY light and the ERROR light flash When this happens the lamp assembly must be replaced For details contact your dealer Caution Users should never open the scanner case Information Reference List Engineering Change Notices None Product Support Bulletins None Related Documentation TM ACTSCANII ActionScanner II Service Manual PL ACTSCANII ActionScanner II Parts Price List 4004518 ActionSca...