4.2 Programming modes
Proceed as follows to either check or set up modes:
-
Switch off Talk functions.
-
Then simultaneously hold down the keys call light (L) and S-CALL (S).
-
Next press the Talk key 5 times in succession. The buzzer sounds once. Service mode is now active. Now release
the call light and S-CALL keys.
-
With the call light key L, step through the menu list. Pressing once displays the next menu item. You can also press
the L key a number of times to go direct to the required menu item. The current menu item is signalled by the
sounding of the buzzer in the frequency of the item selected.
-
You can change the setting of the current menu item by pressing the S-CALL key “S”. The channel indicator
displays the setting, i.e. an activated menu item is indicated by an LED that is lit up.
-
If all settings are made, by pressing Talk key I, you exit Service mode and the settings are saved. Saving and
exiting are possible at any time.
4.2.1 Examples
-
Switch off Talk functions.
-
Then simultaneously hold down the keys call light L and S-CALL S.
-
Next press the Talk key 5 times in succession. The buzzer sounds once. Service mode is now active. Now release
the call light and S-CALL keys.
-
Press the “L“ key once, then after about 500ms, the buzzer sounds once. You are now in Service mode Position 1
(Mic Electret).
-
Press the “L“ key twice, then after about 500ms, the buzzer sounds four times. You are now in Service mode Position
4 (Buzzer B).
-
Press the “L“ key five times, then after about 500ms, the buzzer sounds nine times. You are now in Service mode
Position 9 (Call A).
-
Press the “L“ key six times, then after about 500ms, the buzzer sounds twice. You are now in Service mode Position
2 (Mic Gain).
-
You can change the current setting of the menu item by pressing the S-CALL key “S”. The channel indicator
displays the setting, i.e. an activated menu item is indicated by an illuminated LED.
-
If all settings are made, by pressing Talk key I, you exit Service mode and the settings are saved. Saving and
exiting are possible at any time.
RIEDEL RPL_EN_BP-2002e-Rev2.1.doc: 2 12.12.2002 11:29
Page 8 of 11
Röttgen 8, D-42109 Wuppertal,
Alterations reserved
Tel. +49 (0) 202 / 270 370