Designated purpose of use
Rieber GmbH & Co. KG
5
2.2 Technical
data
•
1N AC 230V 50/60 Hz, 12 V-direct current, 15 W, main cable approx. 1.8 m, 15 W,
protection type IP3X
•
Throughput 13 litres per minute; vacuum of about 500 mm bar; a period of about 2
minutes must lapse after each process - giving the device time to cool down
•
Permitted ambient temperature 0
°C to 55
°C at a relative humidity of 75%
•
Weight about 400 g, dimensions approx. 20 x 14 x 5 cm; Housing is made of plastic
2.3 Accessories
Use coordinated products
Tips for users
Using our accessories, vacu
lid
®
saves on energy and the range of uses increases.
Rieber products are labeled 'Rieber'.
►
Use vacu
lid
®
and
thermoplates
®
plus accessories from Rieber GmbH & Co. KG.
▌
Store, prepare, cook, barbecue, boil, portion and serve from a single
container.
3
Designated purpose of use
This chapter discusses the intended use of the product and warns against misuse for your own safety.
General intentions of use include:
•
systems catering, catering, hotel business, gastronomy, private and home use.
•
Suitable accessories include Gastronorm containers such as the GN-thermo
plates
®
by Rieber.
•
The device is not designed for permanent operation. A period of about 2 minutes
must lapse after each process during which the device can cool down. Do not use
the device until after this period.
•
By vacuumizing you can store/preserve foodstuffs for longer.
•
Intended use also includes observing the technical data.
•
Please observe the section "Vacuumizing - general information'.
Avoid foreseeable misuse:
•
vacu
lid
®
- vacuum pump may not be used in any other way.
•
Do not use any other containers such as jars or plastic bowls. These containers can
implode through the pressure caused by the vacuum and can cause injuries. Use
the vacu
lid
®
accessories.
•
The quality of foodstuffs as well as compliance with rules of hygiene is the
prerequisite for longer storage periods and the freshness of the goods.