8.3.3
Note on operation of the control
… programmable control
1
ON/OFF rocker switch → …lights up green with the power to the appliance is switched on
2
Cooling operation display → LED lights up red during the
cooling process
coolant running)
.
3
Defrosting operation display → LED lights up red during the
defrosting process
.
4
Ventilation operation display → LED lights up red when
convection cooling
is active (fans
running).
5
Button A
: Different functions are allocated to button "A" by means of parameterisation. The button
must be pressed for at least half a second.
The button has no function on this appliance and only indicates cooling.
6
SET button
: While the SET button is pressed, the setpoint value is displayed.
The SET button is also used for parameter setting.
7
Button B
: Different functions are allocated to button "B" by means of parameterisation. On this
appliance this function is to switch the lighting in the appliance ON/OFF (option).
8
DOWN button
: An alarm can be acknowledged with the DOWN button. The internal buzzer is then
switched off.
9
UP button
: A defrosting process can be initiated at any time by pressing the UP button for
3 seconds
. During defrosting the defrosting operation display LED (3) lights up. The LED (3)
flashes if defrosting is required, but may not yet be started due to disable conditions.
# Important note
Every 4 hours
an automatic defrosting operation takes place, which prevents the evaporator from icing
up. The defrosting phase takes around
20 minutes
when the power to the appliance is switched on
.
The
defrosting
LED (3) lights up.
If the power supply is interrupted, for example during transport, this interruption time must also be
taken into account. It is important to remember that when the power supply is restarted, the defrosting
phase will continue running.
The time should not be extended if cooling is unavailable. Take note of the defrosting operation
display (3).
# Switch the appliance on
Switch the appliance on. To do this, press the green rocker switch to POWER OFF (O).
▌
The green rocker switch lights up.
▌
The display on the controller indicates the ACTUAL temperature.
▌
The cooling operation display (2) lights up during the cooling process.
Pre-cool the appliance before filling if possible,
for around 20 minutes
.