background image

2. Set the microDrain Reel approximately six feet (two

meters) from the entry point. This provides ample

pushrod for grasping and manipulating without excess

dragging on the ground. When properly located, push

cable will only come off the reel when you pull it.
Preferably, lay the microDrain Reel on its back with

the camera unit and pushrod on top. There are foot

pads provided on the cord wrap to allow placement

in this position. This position provides the greatest

stability and helps to prevent tipping of the reel dur-

ing use.

Operating Instructions

WARNING

Always wear eye protection to protect your eyes
against dirt and other foreign objects.

When inspecting drains that might contain haz-
ardous chemicals or bacteria, wear appropriate
protective equipment, such as latex gloves, goggles,
face shields or respirators, to prevent burns and in-
fections.

Do not operate this equipment if operator or ma-
chine is standing in water. Operating machine while
in water increases the risk of electrical shock.
Rubber soled, non-slip shoes can help prevent slip-
ping and electric shock, especially on wet sur-
faces.

Follow operating instructions to reduce the risk of
injury from electrical shock and other causes.

1. Make sure all equipment is properly set up.
2. Pull several feet of pushrod from the reel. Make sure

the camera window is clean. In some cases, a slight

film of detergent on the window may minimize debris

sticking to the window. Place the camera unit into the

line to be inspected. 

If running the camera through a porcelain

fixture (such as a toilet) or in an inlet with sharp
edges that could damage the pushrod, you may
want to use a guide made of PVC or other non mark-
ing pipe to prevent damage to the fixture or the
pushrod.

See section “Using Guide Tubes”:

3. Turn the CCU on. As per the specific CCU operator

manual, adjust the camera head LED lighting bright-

ness and the display image. As the pipe material

and other factors vary, it may be necessary to make

Ridge Tool Company

9

SeeSnake

®

microDrain™ Inspection System

outer locking sleeve on the cable connector to retain the

system cable in place. 

Do not twist the cable while

tightening the locking sleeve. This can damage the
cable.

See Figure 13 and 14.

Figure 13 – Connecting To A SeeSnake CCU

Figure 14 – microDrain System Connected to

SeeSnake

®

MINIPak Monitor CCU

If  using  a  microDrain  System  set  up  for  use  with  a

microEXPLORER Camera monitor, it can be converted

for use with other SeeSnake CCU’s (or vice versa) by

changing the system cable as detailed in the assembly

section.
Set up the microEXPLORER Camera monitor or CCU as

per its instructions. If using the microEXPLORER Camera

monitor or a battery powered CCU, make sure that the re-

quired batteries are fully charged and installed.

Placement

1. Place the microEXPLORER Camera monitor or CCU

monitor to allow easy viewing while manipulating the

pushrod and camera. Usually right next to the entry

point for the pushrod is a good choice. The location

should not be wet or allow the monitor unit to get wet

during use.

NOTICE

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание SeeSnake microDrain 33103

Страница 1: ...Snake microDrain SeeSnake microDrain Record Serial Number below and retain product serial number which is located on nameplate Serial No www GlobalTestSupply com Find Quality Products Online at sales...

Страница 2: ...lling System Cable 6 Reversing Installing The Display Cradle microEXPLORER Camera Monitor 6 Connecting microEXPLORER Camera Monitor to microDrain System 7 microDrain System Ball Guides 7 Installing Ba...

Страница 3: ...l or medication A moment of inattention while operating equipment may result in serious personal injury Use personal protective equipment Always wear eye protection Protective equipment such as dust m...

Страница 4: ...croDrain Inspection System to re duce the risk of electrical shock fire or other se rious personal injury SAVE THESE INSTRUCTIONS Keep this manual with the equipment for use by the oper ator If you ha...

Страница 5: ...ps and very small radius bends which conventional in spection systems often cannot inspect When using the microDrain Reel with an appropriate SeeSnake control unit the operator can connect an ex terna...

Страница 6: ...e case latches on either side of the microDrain Reel Figure 4 Figure 4 Unlatching the microDrain Reel Case 3 Open the front case and locate camera head in the pushrod drum 4 Route the camera head out...

Страница 7: ...ve four screws holding the cord wrap arms and cradle to the case Remove the cord wrap arms and the screws Figure 9 Figure 9 Cradle Support and Cord Wrap Arms 2 Use one of the screws to remove the nuts...

Страница 8: ...equally in all directions and help keep the camera lens clear during inspections Figure 12 Ball guides should be used when possible because they reduce wear and tear on the camera system If you run i...

Страница 9: ...can cause sparks Clear level stable dry place for machine and op erator Do not use the machine while standing in wa ter If needed remove the water from the work area Clear path to electrical outlet if...

Страница 10: ...he line to be inspected If running the camera through a porcelain fixture such as a toilet or in an inlet with sharp edges that could damage the pushrod you may want to use a guide made of PVC or othe...

Страница 11: ...ny sharp edges on the inlet that could cut grab or damage the pushrod Grasp and push short sections of pushrod at a time and keep your hands near the inlet to better control the pushrod and prevent it...

Страница 12: ...to the pushrod Figure 18 If needed jiggle the camera head in any standing water to rinse any debris from the camera window Depending on what is encountered during the inspection it may help to add rem...

Страница 13: ...are using Retrieving The Camera Once the inspection has been completed pull the pushrod back with slow steady force Continue running water down the line if possible to help clean the pushrod A towel c...

Страница 14: ...nake 33113 microDrain System Slip Ring Module for microEXPLORER Camera Monitor Various RIDGID SeekTech or NaviTrack Locators Various RIDGID SeekTech or NaviTrack Transmitters Various RIDGID SeeSnake C...

Страница 15: ...monitor display unit Check alignment and pins of connection to microDrain System unit from camera control or display unit Check orientation seating and pin condition in the SeeSnake connection Set vi...