background image

 

Ridge Tool Company 

 Elyria, Ohio 

 U.S.A  

www.seektech.com

 

3

 

SeekTech  ST-305 Line Transmitter 

reduce the risk of electric shock and equipment 
damage. 

 

Store idle tools out of the reach of children 
and other untrained persons

. Tools are 

dangerous in the hands of untrained users. 

 

Maintain tools with care.

 Properly maintained 

tools are less likely to cause injury. 

 

Check for breakage of parts, and any other 
conditions that may affect the transmitter’s 
operation. 

If damaged, have the tool serviced 

before using. Many accidents are caused by 
poorly maintained tools. 

 

Use only accessories that are recommended 
by the manufacturer for your tool.

 

Accessories that may be suitable for one tool 
may become hazardous when used on another 
tool. 

 

Keep handles dry and clean; free from oil 
and grease.

 Allows for better control of the tool. 

 

Protect against excessive heat.

 The product 

should be situated away from heat sources 
such as radiators, stoves or other products 
(including amplifiers) that produce heat.  

Service 

 

Tool service must be performed only by 
qualified repair personnel. 

Service or 

maintenance performed by unqualified repair 
personnel could result in injury. 

 

When servicing a tool, use only identical 
replacement parts.

 Follow instructions in the 

Maintenance Section of this manual. Use of 
unauthorized parts or failure to follow 
maintenance instructions may create a risk of 
electrical shock or injury. 

 

Follow instructions for changing 
accessories. 

Accidents are caused by poorly 

maintained tools. 

 

Provide proper cleaning.

 Remove battery 

before cleaning. Do not use liquid cleaners or 
aerosol cleaners. Use a damp cloth for 
cleaning. 

 

Conduct a safety check.

 Upon completion of 

any service or repair of this product, ask the 
service technician to perform safety checks to 
determine that the product is in proper 
operating condition. 

 

Damage to the product that requires service.

 

Remove the batteries and refer servicing to 
qualified service personnel under any of the 
following conditions: 

o  If liquid has been spilled or objects have 

fallen into product; 

o  If product does not operate normally by 

following the operating instructions; 

o  If the product has been dropped or 

damaged in any way; 

o  When the product exhibits a distinct change 

in performance. 

CAUTION

 

Remove batteries entirely before shipping. 

If you have any questions regarding the service or 
repair of this machine, call or write to: 

Ridge Tool Company 
Technical Service Department 
400 Clark Street 
Elyria, Ohio 44035-6001 
Tel: (800) 519-3456 
E-mail: 

[email protected]

 

www.ridgid.com

 

In any correspondence, please give all the 
information shown on the nameplate of your tool 
including model number and serial number. 

     

DANGER

 

Important Notice 

The SeekTech ST-305 is intended for use with a 
SeekTech locator/reciever. The locator is a 
diagnostic tool that senses electromagnetic fields 
emitted by objects underground. It is meant to aide 
the user in locating these objects by recognizing 
characteristics of the field lines and displaying them 
on the screen. As electromagnetic field lines can be 
distorted and interfered with it is important to verify 
the location of underground objects before digging. 

Several utilities may be underground in the 
same area. Be sure to follow local guidelines 
and one-call service procedures. 
Exposing the utility is the only way to verify its 
existence, location, and depth. 
Ridge Tool Co., its affiliates and suppliers, will 
not be liable for any injury or any direct, 
indirect, incidental or consequential damages 
sustained or incurred by reason of the use of 
the  SeekTech ST-305. 

 

Содержание SeekTech ST-305

Страница 1: ...pe and Cable Line Transmitter WARNING Read this operator s manual carefully before using this tool Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious personal injury U S Patent Pending ...

Страница 2: ...ER 7 USING THE ST 305 LINE TRANSMITTER 8 DIRECT CONNECT METHOD 8 FCC LIMITS 10 USEFUL OPERATING TIPS 10 DUAL FREQUENCY TRANSMISSION 10 INDUCTIVE CLAMP METHOD 11 INDUCTIVE MODE 11 HIGH VOLTAGE INDICATOR 13 USEFUL INFORMATION 13 RESISTANCE AND IMPEDANCE 13 USING HIGH AND LOW FREQUENCIES 13 TRANSPORTATION AND STORAGE 14 MAINTENANCE AND CLEANING 14 LOCATING FAULTY COMPONENTS 14 TROUBLE SHOOTING GUIDE ...

Страница 3: ...ny Elyria Ohio U S A www seektech com 1 SeekTech ST 305 Line Transmitter SeekTech Line Transmitter Record the Serial Number of your unit below and retain for your records Serial Number SeekTech ST 305 Line Transmitter ...

Страница 4: ...use the battery to explode so do not dispose of in a fire Some countries have regulations concerning battery disposal Please follow all applicable regulations Personal Safety Avoid Traffic Pay close attention to moving vehicles when using on or near roadways Wear visible clothing or reflector vests Such precautions may prevent serious injury Stay alert watch what you are doing and use common sense...

Страница 5: ...r repair of this product ask the service technician to perform safety checks to determine that the product is in proper operating condition Damage to the product that requires service Remove the batteries and refer servicing to qualified service personnel under any of the following conditions o If liquid has been spilled or objects have fallen into product o If product does not operate normally by...

Страница 6: ...the sole power option available on the ST 305 The High Voltage LED will light if the unit encounters more than approximately 62 VAC RMS WARNING In compliance with Federal Standard EN 50249 the ST 305 line transmitter is designed to withstand up to 250 VAC 50 60 Hz excitation between the two leads The user is cautioned not to deliberately connect to live power lines If the transmitter indicates the...

Страница 7: ...io U S A www seektech com 5 SeekTech ST 305 Line Transmitter Transmitter Components Connection Leads and Clips Keypad Inductive Clamp Jack Frequency Mode and Power LEDs Ground Stake Storage Battery Case Figure 1 ST 305 Components ...

Страница 8: ...ency used to initiate dual frequency mode Power On Off Used to power the ST 305 on and off and to set current level Induction Mode Toggle Used to switch the ST 305 into Inductive Mode Induction Mode Indicator Flashes when unit is connected to an Inductive Clamp Illuminated in Inductive Mode High Voltage Warning Warning light when high voltage is encountered 62V AC RMS Figure 2 Keypad and Display F...

Страница 9: ...reduce battery life Batteries often recover after being subjected to high loads If time is allowed batteries may recover enough to offer additional hours of operation Powering Up Down Turn the power ON by depressing the Power Key on the keypad The current frequency and power level LEDs will light up A beep will sound Turn the unit OFF by depressing the Power Key on the keypad for 2 seconds Three t...

Страница 10: ...ously in direct connect mode See page 10 Inductive Clamp The jaws of the inductive clamp encircle the target conductor there is no metal to metal contact The inductive clamp is an optional accessory See page 11 Inductive Mode internal coils The transmitter is placed over and in line with a conductor Its internal antenna generates a dipole field which energizes the target conductor below ground ind...

Страница 11: ...ashing rapidly indicating a 262 kHz frequency European version a long press will select 93 kHz causing the 33 kHz LED to flash rapidly For information on using dual frequencies see page 10 3 Check the Circuit and Adjust Power Level Confirm the circuit is grounded by checking the connection to the ground stake is secure and the stake is firmly embedded in the ground To adjust the power level press ...

Страница 12: ...necessary The transmitter s leads can act as antennas broadcasting a strong signal If locating close to the transmitter keep the leads short by stowing the excess length on the transmitter s body This will reduce the amount of interfering signals from the leads Where possible place the transmitter away from the area of the intended locate This is especially true in Inductive Mode to avoid coupling...

Страница 13: ...with the Direct Connect Method Operational frequency choices for use with an Inductive Clamp are 1 kHz 8 kHz and 33 kHz Figure 10 Inductive Clamp Attached to a Conductor Inductive Mode 1 Be sure that the transmitter is positioned correctly over the line Figure 11 Orientation to the Line Inductive Mode Note A slight tilt to the axis of the conductor can help reduce the probability of air coupling s...

Страница 14: ...lly round in shape just as it would be if the transmitter were connected directly But the primary field from the transmitter which does the inducing is not round and is not the same as the field set up on the pipe or wire Figure 13 Air Coupling Near the transmitter the receiver reads on the local dipole field around the transmitter The field generated by the transmitter has a shape something like ...

Страница 15: ...ng High and Low Frequencies Understanding the behavior of different frequencies under different conditions can be important in doing effective and accurate locates In both direct connect and Inductive Mode the ST 305 is essentially doing the same thing imposing a wave of traceable energy onto the target pipe or line This electrical energy rises and falls a certain number of times per second which ...

Страница 16: ...g lead end last and secure the ends under the prongs provided on the transmitter Before transporting make sure that the unit is powered OFF to preserve battery power Also make sure that the ST 305 line transmitter is secure and does not bounce around or get bumped by loose equipment CAUTION Remove batteries entirely before shipping The ST 305 line transmitter should be stored in a cool dry place N...

Страница 17: ...r core damage using test on page 13 Check orientation of batteries Check that the batteries are fresh or charged Unit will not turn ON Check to see that the battery contacts are OK 93 kHz signal not received Check that receiver is set to the actual 93kHz freguency of 93 696 Hz Some receivers use a different frequency for 93 kHz 93 622 9 Update SeekTech locator software Specifications Weight 1 6 lb...

Страница 18: ...eplaced at RIDGE TOOL S option and returned at no charge or if after three attempts to repair or replace during the warranty period the product is still defective you can elect to receive a full refund of your purchase price What is not covered Failures due to misuse abuse or normal wear and tear are not covered by this warranty RIDGE TOOL shall not be responsible for any incidental or consequenti...