background image

SPECIFICATIONS

POWER SUPPLY 
REQUIREMENTS

120 V, 60 Hz

MOTOR

               Single Phase, Dielectric Oil Filled

HORSEPOWER

 1/2 HP

LIQUID TEMPERATURE

40° F - 120° F

CIRCUIT REQUIREMENTS

 15 A (minimum)

DIMENSIONS

                16-5/8 in. high x 9-5/8 in. base 

ON LEVEL (FACTORY SET)

Approximately 19 in. 

OFF LEVEL (FACTORY SET)

Approximately 10.5 in. 

610001W-005 C 09/19

CONSTRUCTION

MOTOR HOUSING

Cast Iron

 

VOLUTE

                             Cast Iron

IMPELLER 

Glass Reinforced Thermoplastic

SHAFT 

Steel

DISCHARGE

2 in. NPT

Sewage Pumps

PERFORMANCE (Gal/hr)

Model

HP

Discharge Head (Lift Distance)

   0 ft         5 ft       10 ft      15 ft

RWCS50T

1/2

10000

9900

8100

3600

Intended for Indoor Use Only

    Operating Instructions and Parts Manual                                                                              RWCS50T

Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.

© 2019, RIDGID TOOL COMPANY

Содержание RWCS50T

Страница 1: ...Thermoplastic SHAFT Steel DISCHARGE 2 in NPT Sewage Pumps PERFORMANCE Gal hr Model HP Discharge Head Lift Distance 0 ft 5 ft 10 ft 15 ft RWCS50T 1 2 10000 9900 8100 3600 Intended for Indoor Use Only Operating Instructions and Parts Manual RWCS50T Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself a...

Страница 2: ... interrupter GFCI All wiring must be performed by a qualified licensed electrician and comply with the National Electric Code and all applicable local codes and ordinances POUR PLUS DE SÉCURITÉ la prise de courant doit être protégée par un disjoncteur de fuite à la terre Tout le câblage doit être effectué par un électricien qualifié et être conforme au Code électrique national et à tous les codes ...

Страница 3: ...CHEMINEMENT D EAU DESTINÉE À LA CONSOMMATION Ne pas utiliser la pompe pour transporter de l eau qui sera utilisée comme de l eau potable destinée à la consommation La pompe doit être utilisée uniquement dans les applications pour lesquelles elle est conçue DO NOT USE AN EXTENSION CORD OR SURGE PROTECTOR Extension cords and or surge protectors could present a safety hazard if not sized properly bec...

Страница 4: ...vels exists UNE ALARME AUTONOME DE NIVEAU D EAU ÉLEVÉ OU UNE POMPE DE SAUVEGARDE DOIVENT ÊTRE UTILISÉES en cas de risque de dégâts matériels causés par des niveaux d eau élevés REPLACE THE TETHER SWTICH EVERY TWO 2 YEARS This required maintenance will reduce the risk of improper pump operation switch failure and or flooding REMPLACER LE COMMUTATEUR TOUS LES DEUX 2 ANS Cet entretien réduira le risq...

Страница 5: ...not reduce the discharge pipe 3 size below that which is provided on the pump 6 7 A union 2 should be installed above the basin to allow easy removal of the pump 6 for cleaning and service 8 Install a check valve 1 required to prevent back flow It should be installed above the union 9 A gate valve or ball valve should be installed above the check valve if required by local regional or state codes ...

Страница 6: ...cessively high or low voltage inadequate wiring incorrect motor conditions or that the motor is at the end of its product life TROUBLESHOOTING Symptoms Possible Cause s Suggested Remedies Pump will not start or run 1 Water level too low 2 Blown fuse or tripped circuit breaker 3 Low supply voltage 4 Motor 5 Switch 6 Inlet clogged 7 Switch obstruction 8 GFCI 1 Water must be at the appropriate level ...

Страница 7: ...e proper pump size 5 Remove and examine check valve for proper installation and free operation 6 Open valve Pump trips GFCI 1 Bad GFCI 2 Bad pump 1 Contact an electrician to verify GFCI operation 2 Replace pump ROUTINE MAINTENANCE The pump should be inspected monthly for pump movement or buildup of debris on the switch or float Reposition pump if it has moved Remove any debris that could interfere...

Страница 8: ...WARRANTY SERVICE PARTS SHEET REPLACEMENT PARTS REPAIR KITS MODEL ALL MODELS REF NO DESCRIPTION PART NUMBER 1 TETHER SWITCH 56835 WYN1 2 10 FT POWER CORD 31006 WYN2 2 8 ...

Страница 9: ...AGREEMENTS EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL ...

Страница 10: ...___________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ ____________...

Отзывы: