WARNING:

Do not connect to power supply until assembly is 
complete. Failure to comply could result in accidental 
starting and possible serious personal injury.

ASSEMBLY

INSTALLING THE DIPSTICK

See Figure 3, page 17.

The air compressor has a label installed between the oil fill 
hole and a travel cap. Before using the unit the first time, 
remove travel cap and label and insert supplied dipstick. 
Make sure to add oil before first use. See 

Checking the Oil 

before first time operation.

OPERATION

DANGER:

Drain air from tanks prior to disassembling the 
check valve, drain valve or safety relief valve. 

WARNING:

Do not allow familiarity with products to make you 
careless. Remember that a careless  fraction of a 
second is sufficient to inflict severe injury.

WARNING:

Always wear eye protection with side shields 
marked to comply with ANSI Z87.1. Failure to do 
so could result in objects being thrown into your 
eyes resulting in possible serious injury.

WARNING:

This equipment incorporates parts, such as snap 
switches, receptacles, and the like that tend to 
produce arcs or sparks and, therefore, when 
located in a garage, it should be in a room or 
enclosure provided for the purpose, or should be 
18 in. or more above the floor.

WARNING:

Do not attach any tools to the open end of the hose 
until start-up has been completed.

CAUTION:

Do not use in an environment that is dusty or 
otherwise contaminated. Using the air compressor 
in this type of environment may cause damage to 
the unit.

APPLICATIONS

Air compressors are utilized in a variety of air system 
applications. Match hoses, connectors, air tools, and 
accessories to the capabilities of the air compressor.
You may use this product for the purposes listed below:

 

Operating some air-powered tools

 

Operating air accessories such as air nozzles and 

automotive tire inflators

CHECKING THE OIL

See Figures 3 - 4, page 17.

Always check the oil when the unit is sitting on a level surface 
and before first use.

To check the oil level using the sight glass:

 

The sight glass is located below the oil fill hole. There is 
a red dot in the center of the glass.

 

An oil level at the top of the red dot indicates oil is at 
maximum level. 

 

An oil level at or below the bottom of the red dot indicates 
oil is below desired level, and oil should be added.

To check the oil level using the dipstick:

  Insert the dipstick into the oil fill hole completely. Remove 

the dipstick and check the oil level. 

  Make sure the reading is between the MIN and MAX 

reference levels on the dipstick. 

 NOTE: 

Never let the oil drop to a level lower than MIN. 

Maximum level is reached when the oil reaches the MAX 
level reference on the dipstick.

  Reinsert the dipstick securely into the oil fill hole.

To add oil:

  Remove the dipstick. 

  Using a funnel, carefully pour oil into the oil fill hole. Refill 

only with synthetic oil SAE 5W40. 

 

NOTE: 

Avoid using too much oil. Ensure that the level of 

the oil does not exceed the maximum reference level on 
the dipstick.

  Reinsert the dipstick securely into the oil fill hole.

Содержание OL40135SS

Страница 1: ...nnement robuste et sans probl me AVERTISSEMENT Pour r duire les risques de blessures l utilisateur doit lire et veiller bien comprendre le manuel d utilisation avant d employer ce produit Merci d avoi...

Страница 2: ...urify the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 Compressed Gas Association 4221 Wa...

Страница 3: ...hers in the work area Some environments will require the use of head protection equipment When required the employer and user must ensure that head protection marked to comply with ANSI Z89 1 is used...

Страница 4: ...oward yourself or others Do not operate this air compressor if it does not contain a legible warning label Do not continue to use a tool or hose that leaks air or does not function properly Always dis...

Страница 5: ...be in a room or enclosure provided for the purpose or should be 18 in or more above the floor Never store a tool with air connected Storing the tool with air connected can result in unexpected firing...

Страница 6: ...Do not smoke while spraying or spray where spark or flame is present Keep compressors as far from the spray ing area as possible at least 15 feet from the spraying area and all explosive vapors Risk o...

Страница 7: ...their meaning Proper interpretation of these symbols will allow you to operate the product better and safer V Volts Voltage A Amperes Current Hz Hertz Frequency cycles per second Alternating Current...

Страница 8: ...is product is powered by a precision built electric motor It should be connected to a power supply that is 120 V AC only normal household current 60 Hz Do not operate this product on direct current DC...

Страница 9: ...Per Minute A unit of measure of air delivery Tank Pressure Gauge Indicates the pressure in the air tank Air Filter Porous element contained within a metal or plastic housing attached to the compressor...

Страница 10: ...tomatically release air if the air tank pressure exceeds the preset maximum SIGHT GLASS The sight glass lets you check to see if oil should be added TANK PRESSURE GAUGE The tank pressure gauge indicat...

Страница 11: ...compressor in this type of environment may cause damage to the unit APPLICATIONS Air compressors are utilized in a variety of air system applications Match hoses connectors air tools and accessories t...

Страница 12: ...ur application Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on more frequently n When finished always drain the tank and unplug the unit Ne...

Страница 13: ...is device could fly up and hit you Failure to heed this warning could result in death or serious personal injury The safety valve will automatically release air if the air tank pressure exceeds the pr...

Страница 14: ...igure 12 page 18 Turn the air filter cover counterclockwise approximately one quarter turn Remove the cover Remove the air filter Install new air filter Replace the air filter cover and secure it by t...

Страница 15: ...w voltage Lack of proper ventilation room tem perature too high Wrong gauge wire or length of exten sion cord Check with voltmeter Move compressor to well ventilated area Check for proper gauge wire a...

Страница 16: ...m When requesting warranty service you must present the original dated sales receipt The authorized service cen ter will repair any faulty workmanship and either repair or replace any part covered und...

Страница 17: ...15 NOTES NOTAS...

Страница 18: ...n cessaire pour filtrer et purifier l air conform ment aux sp cifications minimum d air respirable de qualit D G 7 1 1966 OSHA 29 CFR 1910 134 de la Compressed Gas Association 4221 Walney Road Fifth...

Страница 19: ...des lunettes de vue ou de s curit et pot geant des d bris projet s sur le devant et les c t s Toujours porter une protection oculaire certifi e conforme la norme ANSI Z87 1 Des quipements de protectio...

Страница 20: ...s d air ou ne fonctionne pas correctement Toujours d brancher l outil des alimentations pneumatique et lectrique avant d effectuer des r glages ou entretiens et lorsque l outil n est pas utilis Ne pas...

Страница 21: ...utiliser un cordon du calibre imm diatement sup rieur Moins le num ro de calibre est lev plus la capacit du fil est grande Un cordon de capacit insuffisante causerait une baisse de la tension de ligne...

Страница 22: ...ntil e Ne pas fumer pen dant la pulv risation ou pulv riser en pr sence de flammes Garder les compresseurs le plus loin possible des zones de pulv risation au moins 4 6 m 15 pi de la zone de pulv risa...

Страница 23: ...ification Une interpr tation correcte de ces symboles permettra d utiliser produit plus efficacement et de r duire les risques V Volts Tension A Amp res Intensit Hz Hertz Fr quence cycles par seconde...

Страница 24: ...t tre mis la terre CARACT RISTIQUES LECTRIQUES CORDONS PROLONGATEURS Utiliser exclusivement des cordons prolongateurs 3 fils dot s d une fiche prise de terre branch s sur une prise triphas e compatibl...

Страница 25: ...e r servoir Indique la pression d air l int rieur du r servoir Filtre air l ment poreux contenu dans un bo tier en m tal ou plastique mont sur la culasse du compresseur pour d barasser l air d aliment...

Страница 26: ...e l air si la pression d air du r servoir exc de la pression maximale pr r gl e VOYANT FEN TRE Le voyant fen tre permet l utilisateur de v rifier s il est n cessaire d ajouter de l huile MANOM TRE DU...

Страница 27: ...l sions graves AVERTISSEMENT Ce produit comporte des pi ces telles que des interrupteurs ressort qui ont tendance produire des arcs ou des tincelles Par cons quent lorsque la machine est utilis e dans...

Страница 28: ...seur d air en r glant la pression d air du r servoir z ro et en ouvrant compl tement les valves de purge pendant 30 minutes UTILISATION METTRE LE COMPRESSEUR EN POSITION MARCHE ET D ARR T Voir la figu...

Страница 29: ...rique enlever et nettoyer des soupapes alors r installer AVERTISSEMENT D brancher le compresseur et vacuer compl tement l air des r servoirs avant de proc der tout entretien Ne pas rel cher la pressio...

Страница 30: ...igure 12 page 18 Tournez le couvercle du filtre air environ un quart de tour dans le sens antihoraire Retirez le couvercle Retirez le filtre air Installez le nouveau filtre air Replacez le couvercle d...

Страница 31: ...ture du local trop lev e Calibre ou longueur de prolongateur incorrect V rifier la tension l aide d un voltm tre Emmener le compresseur un endroit bien a r V rifier le calibre et la longueur du prolon...

Страница 32: ...fabrication et r parera ou remplacera notre choix gratuitement toute pi ce d fectueuse One World Technologies Inc Hwy 8 Pickens SC 29671 tats Unis GARANTIE D ENTRETIEN DE 3 ANS SUR COMPRESSEURS D AIR...

Страница 33: ...15 NOTES NOTAS...

Страница 34: ...ha sido examinado y no debe suponerse o deducirse ninguna conclusi n con respecto al correcto uso del aire de respiraci n Si se altera de cualquier forma este compresor quedan anuladas todas las garan...

Страница 35: ...a protectora de visi n amplia encima de los anteojos normales o de los anteojos de seguridad que ofrecen protecci n frontal y lateral contra part culas que salen disparadas Siempre p ngase protecci n...

Страница 36: ...jo indebidos de esta producto puede causarle lesiones a usted y a otras personas Nunca deje desatendida ninguna herramienta con la manguera de aire conectada NUNCA dirija la herramienta hacia usted u...

Страница 37: ...ensi n Al utilizar un cord n de extensi n utilice uno del suficiente calibre para soportar la corriente que consume el producto Se recomienda que los conductores sean de calibre 14 A W G por lo menos...

Страница 38: ...No fume mientras est rociando con pistola ni roc e donde haya presentes chispas o flamas Mantenga los compresores tan lejos del rea de pintura y de vapores explosivos como sea posible por lo menos a 4...

Страница 39: ...er su significado Una correcta interpretaci n de estos s mbolos le permitir utilizar mejor y de manera m s segura el producto S MBOLO NOMBRE DENOMINACI N EXPLICACI N V Volts Voltaje A Amperes Corrient...

Страница 40: ...ma de corriente como la mostrada en la figura 2 p gina 17 Tambi n dispone de una patilla de conexi n a tierra como la mostrada Este producto debe conectarse a tierra CORDONES DE EXTENSI N S lo utilice...

Страница 41: ...tanque Sirve para indicar la presi n interna del tanque Filtro de aire Es un elemento poroso contenido dentro de un alojamiento de metal o pl stico unido al cilindro de la culata del cilindro del com...

Страница 42: ...icamente si la presi n del aparato receptor del aire sobrepasa el l mite m ximo prefijado VISOR VENTANA El visor ventana permite que el operador verifique si se debe agregar aceite MAN METRO DEL TANQU...

Страница 43: ...extremo abierto de la manguera sin haber efectuado el procedimiento inicial PRECAUCI N No utilice la unidad en ning n entorno polvoriento o contaminado de cualquier forma Si se utiliza el compresor d...

Страница 44: ...ra evitar da arla y sufrir un riesgo de lesiones Para abastecer de aceite la unidad n Retire la varilla de nivel de aceite n Con un embudo vierta cuidadosamente el aceite en la boca de llenado del mis...

Страница 45: ...as n Gire a la derecha las v lvulas de drenaje hasta dejarlas firmemente cerradas FUNCIONAMIENTO REVISI N DE LA V LVULA DE SEGURIDAD Vea la figura 10 p gina 18 PELIGRO No intente forzar o alterar la v...

Страница 46: ...reloj aproximadamente un cuarto de vuelta Extraiga la tapa Extraiga el filtro de aire Instale el filtro de aire nuevo Vuelva a colocar la tapa del filtro de aire y f jela gir ndola en el sentido de l...

Страница 47: ...laci n insuficiente temperatura ambiental demasiado elevada Cord n de extensi n de calibre o longitud equivocados Revise con volt metro Lleve el compresor a un lugar bien ventilado Verifique que el ca...

Страница 48: ...ro de la garant a debe presentar el recibo de venta fechado original El centro de servicio autorizado reparar toda mano de obra deficiente del producto y reparar o reemplazar cualquier pieza cubierta...

Страница 49: ...15 NOTES NOTAS...

Страница 50: ...tte etiqueta D Sight glass voyant d huile visor ventana B A C A Reference level marks rep res de niveau marcas de nivel de referencia B Dipstick jauge varilla de nivel de aceite C Max reference mark m...

Страница 51: ...illo A Reset button l tat initial le bouton bot n de reajuste A A Air filter filtre air filtro de aire B Air filter cover couvercle du filtre air tapa del filtro de aire C Air filter housing logement...

Страница 52: ...eur Noter le num ro de s rie dans l espace ci dessous Lors de toute commande de pi ces d tach es fournir les informations suivantes No de mod le No de s rie Informaci n sobre servicio al consumidor Pa...

Отзывы: