background image

13 – English

MAINTENANCE

WARNING:

Always release all pressure, disconnect from power 
supply, and allow unit to cool to the touch before 
cleaning or making repairs on the air compressor. 

WARNING:

Always wear eye protection with side shields 
marked to comply with ANSI Z87.1. Failure to do 
so could result in objects being thrown into your 
eyes resulting in possible serious injury.

WARNING:

When servicing use only identical replacement 
parts. Use of any other parts may create a hazard 
or cause product damage.

GENERAL MAINTENANCE

Avoid using solvents when cleaning plastic parts. Most 
plastics are susceptible to damage from various types of 
commercial solvents and may be damaged by their use. Use 
clean cloths to remove dirt, dust, oil, grease, etc.

WARNING:

Do not at any time let brake fluids, gasoline, 
petroleum-based products, penetrating oils, etc., 
come in contact with plastic parts. Chemicals can 
damage, weaken or destroy plastIc which may 
result in serious personal injury. 

REPLACING GAUGES, QUICK CONNECT 
 COUPLERS, OR SAFETY VALVE

See Figure 7, page 17.

 

Remove two screws securing the console cover. Remove 
cover and set aside.

 

Using an adjustable wrench, remove the item(s) to be 
replaced (gauges, quick connect couplers, and/or safety 
valve) from the regulator manifold.

 

Apply pipe sealant to new part(s) and then install new 
parts on manifold. Tighten securely.

 

NOTE: 

If replacing gauges, make sure to orient new 

gauges correctly for reading.

 

Reinstall console cover and replace screws. Tighten 
securely.

NOTE: ILLUSTRATIONS START ON PAGE 16 AFTER 

FRENCH AND SPANISH LANGUAGE SECTIONS.

This product has a 90-Day Satisfaction Guarantee Policy, as well  

as a Three-year Limited Warranty. For Warranty and Policy details,  

please go to www.RIDGID.com or call (toll free) 1-866-539-1710.

Содержание OF60150HB

Страница 1: ...CONTENTS General Safety Rules 3 4 Specific Safety Rules 4 5 Symbols 6 7 Electrical 8 Glossary of Terms 9 Features 9 Assembly 10 Operation 10 12 Maintenance 13 Troubleshooting 14 15 Illustrations 16 17...

Страница 2: ...ier de quelle que mani re que ce soit les garanties en vigueur seront d clar es nulles et non avenues RIDGID et One World Technologies Inc d clineront toute responsabilit pour les pertes blessures et...

Страница 3: ...ion will be required in some environments For example the working area may include exposure to a noise level which can lead to hear ing damage The employer and user must ensure that any necessary hear...

Страница 4: ...leaks air or does not function properly Always disconnect the air supply and power supply before making adjustments servicing a product or when a product is not in use Do not attempt to pull or carry...

Страница 5: ...50 feet is not recommended If in doubt use the next heavier gauge The smaller the gauge number the heavier the cord An undersized cord will cause a drop in line voltage resulting in loss of power and...

Страница 6: ...e is present Keep compressors as far from the spray ing area as possible at least 20 feet from the spraying area and all explosive vapors Risk of Electrical Shock Hazardous Voltage Disconnect from pow...

Страница 7: ...lease study them and learn their meaning Proper interpretation of these symbols will allow you to operate the product better and safer V Volts Voltage A Amperes Current Hz Hertz Frequency cycles per s...

Страница 8: ...loss of power and the motor will overheat If the product does not operate when plugged into an outlet double check the power supply SPEED AND WIRING The no load speed of this product is approximately...

Страница 9: ...ck Valve Device that prevents compressed air from flowing back from the air tank to the compressor pump Cut In Pressure Thelowpressureatwhichthemotorwillautomaticallyrestart Cut Out Pressure The high...

Страница 10: ...he like that tend to produce arcs or sparks and therefore when located in a garage it should be in a room or enclosure provided for the purpose or should be 18 in or more above the floor WARNING Do no...

Страница 11: ...let Failure to do so could result in possible serious personal injury OPERATION USING THE AIR COMPRESSOR See Figure 4 page 17 WARNING Risk of bursting Do not adjust pressure regulator knob to result i...

Страница 12: ...r tank pressure exceeds the cut out pressure The valve should be checked before each day of use by pulling the ring by hand n Turn the air compressor on and allow the tank to fill The compressor will...

Страница 13: ...fluids gasoline petroleum based products penetrating oils etc come in contact with plastic parts Chemicals can damage weaken or destroy plastIc which may result in serious personal injury REPLACING GA...

Страница 14: ...ding Defective check valve Insufficient power from receptacle Insufficient power from extension cord Check with voltmeter Check for proper gauge wire and cord length Take compressor to service center...

Страница 15: ...s continuously Defective pressure switch Excessive air usage Piston seal is worn Take compressor to service center Decrease air usage compressor not large enough for tool s requirement Replace piston...

Страница 16: ...e protection oculaire ad quate soit utilis e Nous recommandons d utiliser un masque facial champ de vision se portant par dessus des lunettes de vue ou de s curit et pot geant des d bris projet s sur...

Страница 17: ...le flexible d air branch Ne pas pointer un outil quel qu il soit vers soi ou d autres personnes Ne pas utiliser cet outil s il ne comporte pas d autocollant d avertissement Ne pas utiliser un outil qu...

Страница 18: ...e pi ce n est bloqu e ou cass e v rifier la fixation de chaque pi ce et s assurer qu aucun autre probl me ne risque d affecter le bon fonctionnement de l outil Toute protection ou pi ce endommag e doi...

Страница 19: ...sation ou pulv riser en pr sence de flammes Garder les compresseurs le plus loin possible des zones de pulv risation au moins 6 m 20 pi de la zone de pulv risation et de toutes vapeurs explosives Risq...

Страница 20: ...udier et apprendre leur signification Une interpr tation correcte de ces symboles permettra d utiliser l produit plus efficacement et de r duire les risques SYMBOLE NOM D SIGNATION EXPLICATION V Volts...

Страница 21: ...ourant r sidentiel standard 60 Hz Ne pas utiliser cet outil sur une source de courant continu c c Une chute de tension importante causerait une perte de puissance et une surchauffe du moteur Si le com...

Страница 22: ...comprim contenu dans le r servoir de retourner la pompe Pression de d clenchement Pression laquelle le moteur se remet en marche Pression d arr t Pression laquelle le moteur s arr te automatiquement M...

Страница 23: ...ilisation de pieces et accessoires non recommand s peut entra ner des blessures graves AVERTISSEMENT Ce produit comporte des pi ces telles que des interrupteurs ressort qui ont tendance produire des a...

Страница 24: ...unit sans surveillance si celle ci est branch e ou si elle fonctionne CONNEXION ET D BRANCHER D UN TUYAU AIR NON FOURNI Voir la figure 2 page 16 AVERTISSEMENT Ne jamais d passer la pression nominale d...

Страница 25: ...te augmente le risque de rupture du r servoir d air et repr sente un risque de blessures graves UTILISATION V RIFICATION DE LA SOUPAPE DE S RET Voir la figure 5 page 17 DANGER Ne pas essayer de modifi...

Страница 26: ...ase de p trole les huiles p n trantes etc entrer en contact avec les pi ces en plastique Les produits chimiques peuvent endommager affaiblir ou d truire le plastique ce qui peut entra ner des blessure...

Страница 27: ...e lorsque la pression atteint le minimum Le moteur ronfle mais ne tourne pas ou tourne lentement Tension insuffisante Calibre ou longueur de prolongateur incorrect Enroulement de moteur ouvert ou cour...

Страница 28: ...ir Air de sortie trop humide Exc dent d eau dans le r servoir Humidit excessive Purger le r servoir Emmener le compresseur un endroit moins humide utiliser un filtre air en ligne Le moteur du compress...

Страница 29: ...part culas que salgan disparadas del FRENTE y de los LADOS Se requiere protecci n ocular como protecci n contra sujetadores y desechos que salgan disparados los cuales pueden causar lesiones oculares...

Страница 30: ...Mantenga la manguera y el cord n de corriente lejos de objetos afilados productos qu micos derramados aceite solventes y pisos mojados Antes de usar la unidad revise las mangueras para ver muestran da...

Страница 31: ...nte y desempe ar la funci n a la que est destinada Verifique la alineaci n de las partes m viles que no haya atoramiento de las mismas que no haya piezas rotas el montaje de las piezas y cualquier otr...

Страница 32: ...pistola ni roc e donde haya presentes chispas o flamas Mantenga los compresores tan lejos del rea de pintura y de vapores explosivos como sea posible por lo menos a 6 m 20 pies Riesgo de descarga el c...

Страница 33: ...icamos estudiarlos y aprender su significado Una correcta interpretaci n de estos s mbolos le permitir utilizar mejor y de manera m s segura el producto S MBOLO NOMBRE DENOMINACI N EXPLICACI N V Volts...

Страница 34: ...60 Hz No utilice esta herramienta con corriente continua c c Una ca da considerable de voltaje causa una p rdida de potencia y el recalentamiento del motor Si el compresor no funciona al conectarlo e...

Страница 35: ...Sirve para indicar la presi n interna del tanque Tanque de aire Es un componente cil ndrico que contiene el aire comprimido V lvula de retenci n Es un dispositivo cuya funci n es impedir que el aire...

Страница 36: ...esorios no recomendandos podr a causar lesiones serias ADVERTENCIA Este equipo incorpora piezas como interruptores de acci n inmediata recept culos y piezas similares que tienden a producir arcos o ch...

Страница 37: ...ignada del aire del tanque sea inferior al l mite la presi n de activaci n Tambi n se apagar nuevamente al alcanzar la presi n de interrupci n ADVERTENCIA No exceda el r gimen de presi n de aire de la...

Страница 38: ...car lesiones personales graves FUNCIONAMIENTO REVISI N DE LA V LVULA DE SEGURIDAD Vea la figura 5 pagina 17 PELIGRO No intente forzar o alterar la v lvula de seguridad Cualquier pieza floja de este di...

Страница 39: ...na productos a base de petr leo aceites penetrantes etc lleguen a tocar las piezas de pl stico Las sustancias qu micas pueden da ar debilitar o destruir el pl stico lo cual a su vez puede producir les...

Страница 40: ...esor se enciende cuando la presi n del tanque desciende a la presi n de activaci n El motor zumba pero no funciona o lo hace con lentitud Voltaje bajo Cord n de extensi n de calibre o longitud equivoc...

Страница 41: ...re de descarga Cantidad excesiva de agua en el tanque de aire Alta humedad Drene el tanque Lleve la unidad a un lugar de menor humedad use un filtro de aire en l nea El compresor funciona continuament...

Страница 42: ...E Regulator pressure gauge manom tre du r gulateur regulador de presi n manom trica F Quick connect coupler coupleur ressort acoplador de conexi n r pida G Pressure regulator knob bouton de r gulateu...

Страница 43: ...ouiller tire la perilla y g rela hacia la izquierda para disminuir la presi n luego presione la perilla hacia abajo para fijar Fig 5 A Safety valve soupape de s ret boquilla de la seguridad B Pull to...

Страница 44: ...formations pertinentes lors de tout appel t l phonique ou visite Pour obtenir l adresse du centre de r parations agr le plus proche t l phoner au 1 866 539 1710 ou visiter notre site www ridgid com NO...

Отзывы: