background image

Figure 5 – Filter

5.  Inspect the jetter nozzle orifices for any damage or

blockage.  Blockages  can  be  cleaned  with  a  nozzle
cleaning tool. Use care not to enlarge nozzle orifices
while  cleaning.  Damaged  nozzles  or  nozzles  with
enlarged  orifices  can  decrease  jetter  performance
and should be replaced.

6.  Inspect the hoses, connectors and fittings for wear and

damage.  If  there  are  any  kinks,  cracks,  breaks  or
wear  through  the  outer  jacket  of  the  hose  or  other
damage, do not use the hose. Damaged hoses can
burst or leak high pressure water and cause serious
injury. Replacement hoses and fitting should be rated
at or higher than the jetter pressure rating.

7.  Inspect and maintain the engine per the engine oper-

ator’s manual.

8.  Check engine fuel level 

(Figure 4A)

. If needed, add

unleaded gasoline. See engine operator’s manual for
requirements.  Use  caution  when  handling  gasoline.
Work in a well ventilated area. Never fill the tank while
unit is running, do not overfill tank and do not spill fuel.
Make sure tank cap is securely closed.

9.  Check  the  oil  level(s)  in  the  pump  and  gear  box

through  the  sight  glass  and  add  oil  if  needed 

(see

Maintenance  Instructions  section)

.  Inspect  Engine

as directed in the engine operator’s manual.

Machine and Work Area Set-up

WARNING

Always wear safety glasses, gloves and other appro-

priate protective equipment when setting up your jet-
ter to protect against chemicals and bacteria on the
equipment. Rubber soled, non-slip shoes can help
prevent slipping on wet surfaces.

engines  produce  carbon  monoxide,  a  colorless,
odorless  poison  gas.  Breathing  carbon  monoxide
can cause nausea, fainting or death. do not start and
run engine in an enclosed area, even if doors and
windows are open. only operate outside.

Set-up the jetter and work area according to these
procedures  to  reduce  the  risk  of  injury  from  high
pressure  water,  chemical  burns,  infections,  car-
bon monoxide and other causes, and prevent jetter
damage.

1.  Check work area for:

• Adequate lighting.
• Flammable liquids, vapors or dust that may ignite. If

present,  do  not  work  in  area  until  sources  have
been identified and corrected. The machine is not
explosion proof and can cause sparks.

• Clear, level, stable dry place for machine and oper-

ator.  If  needed,  remove  the  water  from  the  work
area. Wood or other coverings may need to be put
down.

• Jetter location that is in a well ventilated outdoor

area.  Do  not  place  the  jetter  indoors,  even  with
doors  and  windows  open.  Jetter  can  be  located
remotely from the point of use.

• Suitable water supply.
• Clear path to transport the jetter to the set up location.

2.  Inspect  the  drain  to  be  cleaned.  If  possible,  deter-

mine the access point(s) to the drain, the size(s) and
length(s) of the drain, distance to tanks or mainlines,
the nature of the blockage, presence of drain cleaning
chemicals or other chemicals, etc. If chemicals are pre-
sent  in  the  drain,  it  is  important  to  understand  the
specific  safety  measures  required  to  work  around
those chemicals. Contact the chemical manufacturer
for required information.
If needed, remove fixture (water closet, etc.) to allow
access to the drain. Do not feed the hose through a fix-
ture. This could damage the hose and the fixture.

3.  Determine the correct equipment for the application.

See the Specifications section for information on the
jetter.  Drain  cleaners  and  jetters  for  other  applica-
tions can be found by consulting the RIDGID Catalog,
on line at www.RIDGID.com/au/en.

4.  Make sure all equipment has been properly inspect-

ed.

5.  Evaluate the work area and determine if any barriers

are  needed  to  keep  bystanders  away.  Bystanders
can distract the operator. If working near traffic, erect
cones, signs or other barriers to alert drivers.

6

KJ-5000 Water Jetting Machine

Filter

Cover 

Содержание KJ-5000

Страница 1: ...Water Jetting Machine KJ 5000Manual ...

Страница 2: ... Up 6 Water Supply 7 Drain Preparation 7 Hose Set Up 7 Jetter Hose Selection Chart 9 Jetter Nozzle Selection Chart 9 Operating Instructions 9 Jetting the Drain 11 Draining Water from System 12 Using Water Jetter Machine as a Pressure Washer 12 Pressure Washer Operation 13 Hose Reel Brake Adjustment 13 Transportation and Storage 13 Maintenance Instructions Cleaning 13 Engine 13 Battery 13 Pump Lubr...

Страница 3: ...erial number which is located on nameplate Serial No Water Jetting Machine KJ 5000 WARNING Read this Operator s Manual carefully before using this tool Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious personal injury ...

Страница 4: ... Do not force the tool Use the correct tool for your application The correct tool will do the job better and safer at the rate for which it is designed Do not use the power tool if the switch does not Safety Symbols In this operator s manual and on the product safety symbols and signal words are used to communicate important safe ty information This section is provided to improve understanding of ...

Страница 5: ...ing burns and damage to the jetter One person must control the jetting process and water flow If the jetter hose comes out of the drain the operator must be able to shut off the water flow to reduce the risk of the jetter hose whipping causing striking and high pressure injection injuries Always use appropriate personal protective equip ment while handling and using drain cleaning equipment Drain ...

Страница 6: ... out of drains A high ly flexible and lightweight hose is propelled through the drain pipe by the reverse jets on the jetter nozzle and when retrieved scrubs the line flushing debris away The KJ 5000 Water Jetter equipped with a gasoline engine to drive the triplex plunger pump A 36 liter water tank with low water level shut off allows operation with low water supply flow rates Figure 1 KJ 5000 Wa...

Страница 7: ...aintenance section Pre operation Inspection WARNING Before each use inspect your water jetter and cor rect any problems to reduce the risk of serious injury from high pressure water and other causes and prevent jetter damage Always wear safety glasses gloves and other appro priate protective equipment when inspecting your jetter to protect against chemicals and bacteria on the equipment 1 Make sur...

Страница 8: ...ccording to these procedures to reduce the risk of injury from high pressure water chemical burns infections car bon monoxide and other causes and prevent jetter damage 1 Check work area for Adequate lighting Flammable liquids vapors or dust that may ignite If present do not work in area until sources have been identified and corrected The machine is not explosion proof and can cause sparks Clear ...

Страница 9: ...rotective covers in the work area The drain cleaning process can be messy 7 Take the jetter to the well ventilated outdoor work area along the clear path SeeTransportation Section Be aware of possible slip hazards Wear appropriate footwear to help prevent slips Water Supply Run a hose from the water source to the jetter water inlet Use the largest diameter shortest length hose possible A 3 4 I D i...

Страница 10: ...ng pressure or low flow or may damage the jetter with excessive ly high pressures Make sure the nozzle orifices are clear and open See Jetter Nozzle Selection Chart Many nozzles attach to the hose with a quick connect To attach pull the collar back fully insert the male end of the quick connect mounted on the nozzle and release the collar See Figure 9 Confirm that the con nection is secure This wi...

Страница 11: ...and grease traps 3 4 3 16 Flexible Leader optional equipment or 1 4 Remote Reel Sewer and storm water lines 4 6 1 4 Remote Reel or 3 8 Primary Reel Lateral and main lines 6 10 3 8 Primary Reel Penetrating Nozzle Red Cowl Uses three jet thrusters in reverse plus one jet pointed forward to pene trate solid grease sludge or sediment blockages The forward jet blasts a small hole in the blockage for th...

Страница 12: ...gure 11A 11B Open the fuel valve 4 Confirm that the water supply is turned on and the water tank is full Never start the engine without the water supply turned ON This can damage the pump 5 Grip the hose near the pipe opening Open the select ed water control valve ball or foot valve Following the starting instructions supplied in the engine manual start the engine Set the throttle to the full open...

Страница 13: ...alve or foot valve Do not turn the valve ON yet In case of emergency you must be able to turn off water flow Be sure that you have good balance and do not have to overreach You must be able to place one hand on the jetter hose at all times to control and support the hose You must be able to reach the reel for coiling the hose This operating position will help to maintain control of the jetter hose...

Страница 14: ...ded for complete cleaning draining Water from System Draining machine will reduce the jetter weight for trans portation and minimize the chance of water spillage To drain the tank attach a hose to the tank drain and open valve Once the tank is empty disconnect the quick connect from the hose reel and allow water to drain from pump and hoses If using the jetter in cold weather conditions see Machin...

Страница 15: ...ving off reel Figure 15 Figure 15 Reel Brake Adjustment 13 KJ 5000 Water Jetting Machine Transportation and Storage 1 Turn off the fuel valve and the battery isolation switch 2 Drain water from Jetter as needed 3 Coil hoses and secure equipment appropriately All loose material must be removed Transport remote reel separate from jetter 4 Jetter is equipped with wheels to allow transport over smooth...

Страница 16: ... 16 Checking Pump and Gearbox Oil Level Change oil in pump after first 50 hours of operation and every 500 hours of operation after that With the pump warm from operation remove plug on bottom of pump and drain oil into suitable container Replace plug Fill to approx imately half way on the sight glass with SAE 15W 40 Mineral non detergent oil using the checking procedure Approximately 1000 ml of o...

Страница 17: ...r to flush trapped air or debris See Jetter shuts off in use above Clean inlet filter Check hose from tank to pump for kinking confirm hose connections are tight Worn pump cups or valves Take jetter for pump service Replace nozzle must be properly rated for the jet ter Confirm hose connections are tight Take jetter for pump service Adjust Unloader Valve Clean filter Check more frequently Take jett...

Страница 18: ...16 KJ 5000 Water Jetting Machine Hour Meter Reading Date Maintenance Performed Maintenance Log ...

Страница 19: ...ned at no charge or if after three attempts to repair or replace during the warranty period the product is still defective you can elect to receive a full refund of your purchase price What is not covered Failures due to misuse abuse or normal wear and tear are not covered by this warranty RIDGE TOOL shall not be responsible for any incidental or consequential damages No other express warranty app...