11
1. Check compressor for any visible problems,
especially check air filter to be sure it is clean.
2. Pull ring on safety valve and allow it to snap back to
normal position.
3. Drain moisture from tanks daily. Shut compressor off.
Depressurize system prior to draining tanks. Drain
moisture from tanks by opening the tank drain valve
underneath the tanks.
4. Turn power OFF and clean dust and dirt from motor,
tank, air lines and pump cooling fins.
IMPORTANT:
Unit should be located as far from
spraying area as hose will allow to prevent over-spray
from clogging filter.
TANK
The tanks should be carefully inspected at a minimum
of once a year. Look for cracks forming near the welds.
If a crack is detected, remove pressure from tank
immediately and replace.
STORAGE
1. When not in use, compressor should be stored in a
cool dry place.
2. Tanks should be drained of moisture.
3. Hose should be disconnected and hung open ends
down to allow any moisture to drain.
Maintenance
!
WARNING:
Release all pressure and disconnect power before
making any repair .
!
DANGER:
Never attempt to repair or modify a tank! Welding,
drilling or any other modification will weaken
the tank resulting in damage from rupture or
explosion . Always replace worn, cracked or
damaged tanks .
!
WARNING:
Safety valve must be replaced if it cannot be
actuated or it leaks air after ring is released .
NOTICE:
Drain liquid from tanks daily .
Maintenance Schedule
Operation
Daily
Weekly
Drain tanks
●
Check Safety Valve
●
Blow Dirt from Inside Motor
●
Open
Close