background image

6 - English

ELECTRICAL

EXTENSION CORDS

When using a power tool at a considerable distance from 
a power source, be sure to use an extension cord that has 
the capacity to handle the current the product will draw. An  
undersized cord will cause a drop in line voltage, resulting in 
overheating and loss of power. Use the chart to determine 
the minimum wire size required in an extension cord. Only 
round jacketed cords listed by Underwriter’s Laboratories 
(UL) should be used.
When working outdoors with a product , use an extension 
cord that is designed for outside use. This type of cord is 
designated with “W-A” or “W” on the cord’s jacket.
Before using any extension cord, inspect it for loose or ex-
posed wires and cut or worn insulation.

**Ampere rating (on product data plate)

 

 

0-2.0 

2.1-3.4 

3.5-5.0  5.1-7.0  7.1-12.0   12.1-16.0

Cord Length   

 Wire Size (A.W.G.)

 25' 16  16 16 16 14  14

 50' 16  16 16 14 14  12

 100' 16  16 14 12 10  —

**Used on 12 gauge - 20 amp circuit.

NOTE: AWG = American Wire Gauge

 WARNING:

Keep the extension cord clear of the working area 
Position the cord so that it will not get caught on 
lumber, tools, or other obstructions while you are 
working with a power tool. Failure to do so can 
result in serious personal injury.

 WARNING:

Check extension cords before each use. If 

damagedreplace immediately. Never use the 

product with a damaged cord since touching 

the damaged area could cause electrical shock 

resulting in serious injury.

DOUBLE INSULATION

Double insulation is a concept in safety in electric power 
tools, which eliminates the need for the usual three-wire 
grounded power cord. All exposed metal parts are isolated 
from the internal metal motor components with protect-
ing insulation. Double insulated tools do not need to be 
grounded.

 WARNING:

The double insulated system is  intended to protect 
the user from shock resulting from a break in the 
tool’s internal insulation. Observe all normal safety 
precautions to avoid electrical shock.

NOTE: Servicing of a product with double insulation requires 
extreme care and knowledge of the system and should be 
performed only by a qualified service technician. For service, 
we suggest you return the product to your nearest authorized 
service center for repair. Always use original factory replace-
ment parts when servicing.

ELECTRICAL CONNECTION

This product has a precision-built electric motor. It should be 
connected to a power supply that is 

120 V, AC only (normal 

household current), 60 Hz. Do not operate this product on 
direct current (DC). A substantial voltage drop will cause a 
loss of power and the motor will overheat. If the product 
does not operate when plugged into an outlet, double-check 
the power supply.

www.

.com

[email protected]

1.800.561.8187

Содержание 20563

Страница 1: ...tretenu il vous donnera des ann es de fonctionnement robuste et sans probl me AVERTISSEMENT Pour r duire les risques de blessures l utilisateur doit lire et veiller bien comprendre le manuel d utilisa...

Страница 2: ...io Page arri re P g posterior TABLE OF CONTENTS TABLE DES MATI RES NDICE DE CONTENIDO This product has many features for making its use more pleasant and enjoyable Safety performance and dependability...

Страница 3: ...switch or plugging in tools that have the switch on invites accidents Remove adjusting keys or wrenches before turning the tool on A wrench or a key that is left attached to a rotating part of the too...

Страница 4: ...r replaced by an authorized service center Following this rule will reduce the risk of shock fire or serious injury Make sure your extension cord is in good condition When using an extension cord be s...

Страница 5: ...r s manual before using this product Eye Protection Always wear eye protection with side shields marked to comply with ANSI Z87 1 and a full face shield when operating this product Hot Surface To redu...

Страница 6: ...ach use If damagedreplace immediately Never use the product with a damaged cord since touching the damaged area could cause electrical shock resulting in serious injury DOUBLE INSULATION Double insula...

Страница 7: ...th increased trigger pressure ASSEMBLY UNPACKING This product has been shipped completely assembled Carefully remove the tool and any accessories from the box Make sure that all items listed in the pa...

Страница 8: ...r ON depress the switch trigger Re lease the switch trigger to turn the screwdriver OFF VARIABLE SPEED The screwdriver has a variable speed switch for operator control of speed and torque limits Depre...

Страница 9: ...bit The pressure applied will engage the clutch and drive the screw MAINTENANCE WARNING When servicing use only identical RIDGID replacement parts Use of any other parts may create a hazard or cause p...

Страница 10: ...e D Groove rainure ranura E Belt clip clip de ceinture clip para el cinto F Gear casing bo tier d engrenages caja de engranajes G Magnetic bit holder with 1 4 in hex opening porte embout magn tique av...

Страница 11: ...a punta de destornillador B To increase depth of screwdriver bit pour augmenter la profondeur de l embout para aumentar la profundidad de la punta de destornillador C Preset depth setting of screwdriv...

Отзывы: