Page
6
Security
Brands,
Inc.
PROGRAMMING
A user wanting access to program mode must enter the current MASTER CODE. If the MASTER CODE is valid, a GOOD BEEP
will be heard, prompting the user to enter a number corresponding to the SUB-MODE, e.g. MASTER CODE, then (number
corrresponding to SUB-MODE). Once in program mode, the individual will have approximately 15 seconds between
keypresses, or the unit will sound an ERROR BEEP and exit program mode.
SUB-MODES
“1”
Sub-Mode 1 (Enter New Access Codes)
To enter new access codes, enter the MASTER CODE followed by 1, then enter each new access code you wish to
program into the unit.
(MASTER CODE) then 1 then (ACCESS CODE) then (ACCESS CODE) etc. (# to exit)
Should you make an entry error, simply press the
*
key and re-enter the correct data. You may continue entering access
codes until the memory is full or the
#
is pressed. You may select any four-digit access code that is not already in use by
the system. The unit will respond with a GOOD BEEP with the acceptance of each new access code. If you do not receive a
GOOD BEEP after the entry of an access code, you must select a new access code as the one you entered is already in use
by the system. When the memory is full, you will receive a GOOD BEEP indicating the acceptance of the last access code
entered then will sound an ERROR BEEP and exit from program mode.
NOTE: You will not be able to enter this mode if memory is full and will receive an ERROR BEEP.
“2”
Sub-Mode 2 (Delete Access Codes)
To delete any access code from memory, enter the MASTER CODE followed by 2, then enter each access code to be
deleted.
(MASTER CODE) then 2 then (CODE TO BE DELETED) then (NEXT CODE TO BE DELETED) etc. (# to exit)
Should you make an entry error, simply press the
*
key and re-enter the correct data. You may continue deleting access
codes in a successive manner. The unit will respond with a GOOD BEEP with the successful deletion of each access code. If
you do not receive a GOOD BEEP, the access code entered could not be found in memory, and the unit will wait for you to
enter another code to be deleted.
“3”
Sub-Mode 3 (Change Master Code)
To change the MASTER CODE enter the current MASTER CODE followed by 3, and then the new MASTER CODE.
(PRESENT MASTER CODE) then 3 then (NEW MASTER CODE)
Should you make an entry error, simply press the
*
key and re-enter the correct data. You may select any four-digit
code as your new MASTER CODE that is not already in use by the system. The unit will respond with a GOOD BEEP upon
acceptance of the new MASTER CODE and exit from program mode. If the unit does not respond with a GOOD BEEP, you
must select a di
ff
erent code, as the code entered is already in use by the system.
“4”
Sub-Mode 4 (Set Relay Output Time from 0.5 to 9 seconds)
To set the relay output time in seconds enter the current MASTER CODE followed by 4, and then the relay output
time in seconds. NOTE: “0” = 0.5 seconds.
(PRESENT MASTER CODE) then 4 then (RELAY OUTPUT TIME)
Should you make an entry error, simply press the
*
key and re-enter the correct data. You may enter any single-digit value
corresponding from 0.5 to 9 seconds of total length output time. Please note that when you enter
0
, the output time is set
to 0.5 seconds.
“0”
Sub-mode 0 (Clear Memory) WARNING! THIS MODE IS USED TO PERMANENTLY DELETE ALL ACCESS CODES!
To delete all access codes from memory, enter the MASTER CODE followed by 0, and the re-enter the MASTER
CODE
(MASTER CODE) then 0 then (MASTER CODE)
Should you make an entry error, simply press the
*
key and re-enter the correct data. If the second entry of the MASTER
CODE is correct, there will be a short pause, a GOOD BEEP, and then the unit will exit program mode. If the second entry
of the master code is incorrect, the unit will immediately sound a GOOD BEEP and exit program mode.
NOTE: It should not generally be necessary to erase all access codes from memory unless codes are forgotten and/
or are occupying necessary memory space. Good access code maintenance should prevent the necessity of this.
Содержание S-14-100-375UT
Страница 8: ...Page 8 Security Brands Inc CODES MASTER CODE ...
Страница 11: ...Security Brands Inc Page 11 NOTES ...
Страница 12: ......