Minimize pressure loss in the discharge line: ensure that the discharge pipe(s)
is (are) the correct diameter in relation to the distance from the NoNa
+
.
4.1.4
Electrical installation requirements
These requirements are:
Make sure that there is a stable power source.
Make sure that there are sufficient extra plug sockets near the system to
operate, maintain and install it.
Make sure that the equipment and the electricity network is grounded
(earthed).
4.2
Step-by-step installation and commissioning
instructions
The overview below provides a step-by-step plan. You can follow this when installing
and configuring the NoNa
+
.
No.
Step
Section to see for this
Installation
1
Water installation
Check that the inlet pipes and outlet pipes
have been connected correctly to the
following connection points:
Drain water inlet
Drain water outlet
Connection point for fresh water pipe
Wastewater outlet.
"Connecting water supply
(hydronic installation)" on
the facing page.
2
Electrical installation
Connect the supply voltage and network
cable.
"Connecting electrical
components" on page 36.
3
Connect the acid dosing components.
"Connecting acid dosing
components" on page 36.
4
Where applicable: connect the extra sensors,
ring filter, I/O modules and CloudBoX.
"Installing other
components" on page 37.
Commissioning
5
Use the latest software version for the
HortiMaX-Go!.
"Updating software" on
page 39.
6
Check the software configuration.
"Software configuration" on
page 40.
7
Check the software settings.
"Software settings" on
page 43.
8
Calibrate the EC sensors.
"Calibrating the sensors" on
page 46.
NoNa
+
34