No.
Step
Section to see for this
9
Pressurize the NoNa
+
.
"Pressurizing the NoNa+." on
page 47.
10
Test the NoNa
+
by switching it on briefly.
"Testing the NoNa+" on
page 48.
Use the Appendix: "Checklist for step-by-step installation procedure" on
page 69 to check that all installation steps have been completed.
4.3
Connecting water supply (hydronic installation)
For the hydronic installation, you need to connect the pipes to the connection points of
the NoNa
+
. The locations of the various connection points are shown in Figure 4-2.
In Figure 4-2, you will see four connection points for the (drain) water inlet
and outlet.
Figure 4-2:
Location of connection points
No.
Meaning
Pipe size
1
Connection point for fresh water pipe to fresh water tank.
20 mm
2
Drain water inlet
32 mm
3
Wastewater outlet
32 mm
4
Drain water outlet
32 mm
Complete the following steps to connect the unit to the water supply:
1. Remove the dummy pipes from the inlet and outlet of the NoNa
+
. These are
only included for transportation purposes.
2. Connect the NoNa
+
to the drain water inlet and outlet pipes.
3. Connect the NoNa
+
to the wastewater outlet pipe.
4. Connect the fresh water pipe to the fresh water tank.
NoNa
+
35