SP4-XXX: (Scanner)
4
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
Scanner Sub Scan Magnification
008*
1
Scanner Sub Scan
Magnification
Adjusts the magnification in the sub scan direction for
scanning.
[0.0 ~ 1.0 /
0.0
/ 0.1 %/step]
Use the
!
key to toggle b and – before
entering the value. The specification is
±
1%. See
“Replacement and Adjustment – Copy Adjustment” for
details.
Scanner Leading Edge Registration
010
1
Scanner Leading Edge
Registration
Adjusts the leading edge registration for scanning in
platen mode.
[–3.0 ~ 3.0 /
0.0
/ 0.1 mm/step]
(–): The image moves in the direction of the leading
edge.
Use the
!
key to toggle b and – before
entering the value. The specification is 2
±
1.5 mm. See
“Replacement and Adjustment – Copy Adjustment” for
details.
Scanner Side-to-side Registration
011*
1
Scanner Side-to-side
Registration
Adjusts the side-to-side registration for scanning in
platen mode.
[–6.0 ~ +6.0 /
0.0
/ 0.1 mm step]
(–): The image disappears at the left side.
(+): The image appears.
Use the
!
key to toggle b and – before
entering the value. The specification is 2
±
1.5 mm. See
“Replacement and Adjustment – Copy Adjustment” for
details.
Scanner Blank Margin
1 Leading
Edge
2 Trailing
Edge
3 Left
012*
4 Right
Adjusts the erase margin at each side for scanning.
[0.0 ~ 3.0 /
0.0
/ 0.1 mm/step]
Do not adjust this unless the user wishes to have a
scanner margin that is greater than the printer margin.
Scanner Free Run
1 Lamp:
OFF
013
2 Lamp:
ON
Performs a scanner free run with the exposure lamp on
or off.
Press ON on the touch panel to start this feature. Press
OFF on the touch panel to stop.
Scan
1 Shading
ON
017
2 Shading
OFF
Performs a scanner free run with shading on or off. Only
one scan is made.
Press ON on the touch panel to start this feature. Press
OFF on the touch panel to stop.
Black ADS Level
205
1 Black
ADS
Level
Adjusts the erased background level for black-&-white
ADS.
[0
∼
128 /
64
/ 1 /step]
APS Data Confirmation
301
1
APS Data
Confirmation
Displays the status of the APS sensors and platen/DF
cover sensor.