When installing the Device Server Option Type M37, the installation status is
not shown on the Configuration Page.
•
The customer should keep the removed slot cover.
What Do the LED Indications Mean?
When this option is properly installed and recognized by the main machine, the LED
indicators light up under the following conditions.
No.
Light Color
Lights Up When:
1
Green and Yellow
1000BASE-T operates
2
Green
10BASE-T operates
3
Yellow
100BASE-TX operates
Notes for Energy Saving Mode Setting
If a machine with this option enters into the energy saving mode, printing is not possible
because of a communication error . Follow the instructions below to disable the machine’s
entering into the energy saving mode.
1.
Enter SP mode, and then set SP5-191-001 (Power Setting: Power Str) to "0 (Off)".
IP Address Setting
This section describes how to set an IP address on this option manually. Not only can you
set an IP address on the same network segment, but it is also possible to set an IP
address on a different network segment to share a single printer with devices in multiple
networks.
•
The network setting of this option is initially assigned as follows:
IP address: 192.168.100.100 / Subnet mask: 255.255.255.0
•
The network setting of the PC must be in the same network segment to