6.6.2 Vd Correction Factor (Only for Black Toner)
The development bias for toner density detection is changed automatically to
compensate for variations of the triboelectric charge of the developer.
The CPU monitors Vsp and Vsg and calculates the average of Vsp/Vsg x
100(%) during the black developer initial setting (SP65). The result of the
calculation can be monitored by SP64.
The CPU has a software counter (no SP mode display) to count the number
of copies made with the developer. The counter resets to "0" when SP65 is
performed.
Vd correction is made based on the results of the calculation and the data of
the software counter as shown in the following table:
SP data (SP64)
Vsp/Vsg x 100 (%)
Change of development bias voltage
0 to 499 copies
More than 500 copies
0
1
2
3
4
12 to 15
0 to 7
8 to 11
16 to 21
More than 22
±
0 volts
–40 volts
–20 volts
±
0 volts
±
0 volts
±
0 volts
±
0 volts
±
0 volts
+20 volts
+40 volts
FT4220/4222
2-41
STM